1904 matches found
Siemens RuggedCom Rox Heap-based Buffer Overflow (CVE-2024-3447)
A heap-based buffer overflow was found in the SDHCI device emulation of QEMU. The bug is triggered when both s-datacount and the size of s-fifobuffer are set to 0x200, leading to an out-of-bound access. A malicious guest could use this flaw to crash the QEMU process on the host, resulting in a...
Siemens RuggedCom Rox Out-of-bounds Read (CVE-2019-14197)
An issue was discovered in Das U-Boot through 2019.07. There is a read of out-of-bounds data at nfsreadreply. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...
Siemens RuggedCom Rox Out-of-bounds Write (CVE-2019-14198)
An issue was discovered in Das U-Boot through 2019.07. There is an unbounded memcpy with a failed length check at nfsreadreply when calling storeblock in the NFSv3 case. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens RUGGEDCOM RST2428P Improper Access Control (CVE-2025-60876)
BusyBox wget thru 1.3.7 accepted raw CR 0x0D/LF 0x0A and other C0 control bytes in the HTTP request-target path/query, allowing the request line to be split and attacker-controlled headers to be injected. To preserve the HTTP/1.1 request-line shape METHOD SP request-target SP HTTP/1.1, a raw spac...
Siemens RuggedCom Rox Classic Buffer Overflow (CVE-2022-30552)
Das U-Boot 2022.01 has a Buffer Overflow. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid505481; scriptversion"1.2";...
Siemens RUGGEDCOM RST2428P Stack-based Buffer Overflow (CVE-2025-6170)
A flaw was found in the interactive shell of the xmllint command-line tool, used for parsing XML files. When a user inputs an overly long command, the program does not check the input size properly, which can cause it to crash. This issue might allow attackers to run harmful code in rare...
Siemens RUGGEDCOM RST2428P Improper Input Validation (CVE-2026-23030)
In the Linux kernel, the following vulnerability has been resolved: phy: rockchip: inno-usb2: Fix a double free bug in rockchipusb2phyprobe The foreachavailablechildofnode calls ofnodeput to release childnp in each success loop. After breaking from the loop with the childnp has been released, the...
Siemens RUGGEDCOM RST2428P Integer Overflow or Wraparound (CVE-2025-13601)
A heap-based buffer overflow problem was found in glib through an incorrect calculation of buffer size in the gescapeuristring function. If the string to escape contains a very large number of unacceptable characters which would need escaping, the calculation of the length of the escaped string...
Siemens Ruggedcom Rox Improper Neutralization of Argument Delimiters in a Command (CVE-2025-40948)
Affected devices do not properly validate input in the web server's JSON-RPC interface. This could allow an authenticated remote attacker to read arbitrary files from the underlying operating system's filesystem with root privileges. This plugin only works with Tenable.ot. Please visit...
Siemens RuggedCom Rox Out-of-bounds Write (CVE-2019-14196)
An issue was discovered in Das U-Boot through 2019.07. There is an unbounded memcpy with a failed length check at nfslookupreply. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens RUGGEDCOM RST2428P Improper Input Validation (CVE-2025-40214)
In the Linux kernel, the following vulnerability has been resolved: afunix: Initialise sccindex in unixaddedge. Quang Le reported that the AFUNIX GC could garbage-collect a receive queue of an alive in-flight socket, with a nice repro. The repro consists of three stages. 1 1-a. Create a single...
Siemens RuggedCom Rox Improper Input Validation (CVE-2020-10648)
Das U-Boot through 2020.01 allows attackers to bypass verified boot restrictions and subsequently boot arbitrary images by providing a crafted FIT image to a system configured to boot the default configuration. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM RST2428P Out-of-bounds Write (CVE-2026-1484)
A flaw was found in the GLib Base64 encoding routine when processing very large input data. Due to incorrect use of integer types during length calculation, the library may miscalculate buffer boundaries. This can cause memory writes outside the allocated buffer. Applications that process untrust...
Siemens RUGGEDCOM RST2428P Authentication Bypass by Primary Weakness (CVE-2026-3784)
curl would wrongly reuse an existing HTTP proxy connection doing CONNECT to a server, even if the new request uses different credentials for the HTTP proxy. The proper behavior is to create or use a separate connection. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM RST2428P Expired Pointer Dereference (CVE-2025-49795)
A NULL pointer dereference vulnerability was found in libxml2 when processing XPath XML expressions. This flaw allows an attacker to craft a malicious XML input to libxml2, leading to a denial of service. This plugin only works with Tenable.ot. Please visit...
Siemens Ruggedcom Rox Uncontrolled Recursion (CVE-2019-13103)
A crafted self-referential DOS partition table will cause all Das U-Boot versions through 2019.07-rc4 to infinitely recurse, causing the stack to grow infinitely and eventually either crash or overwrite other data. This plugin only works with Tenable.ot. Please visit...
Siemens RuggedCom Rox Out-of-bounds Write (CVE-2019-14193)
An issue was discovered in Das U-Boot through 2019.07. There is an unbounded memcpy with an unvalidated length at nfsreadlinkreply, in the if block after calculating the new path length. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Siemens RUGGEDCOM RST2428P Improper Input Validation (CVE-2026-23025)
In the Linux kernel, the following vulnerability has been resolved: mm/pagealloc: prevent pcp corruption with SMP=n The kernel test robot has reported: BUG: spinlock trylock failure on UP on CPU0, kcompactd0/28 lock: 0xffff888807e35ef0, .magic: dead4ead, .owner: kcompactd0/28, .ownercpu: 0 CPU: 0...
Siemens RuggedCom Rox Out-of-bounds Write (CVE-2019-14204)
An issue was discovered in Das U-Boot through 2019.07. There is a stack-based buffer overflow in this nfshandler reply helper function: nfsumountallreply. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...
Siemens RUGGEDCOM RST2428P Prototype Pollution (CVE-2025-13465)
Lodash versions 4.0.0 through 4.17.22 are vulnerable to prototype pollution in the .unsetand .omitfunctions. An attacker can pass crafted paths which cause Lodash to delete methods from global prototypes. The issue permits deletion of properties but does not allow overwriting their original...