Lucene search
K

11053 matches found

Nuclei
Nuclei
added yesterday65 views

Siemens SIMATIC S7-1200 CPU - Cross-Site Scripting

A cross-site scripting vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. id: CVE-2014-2908 info: name: Siemens SIMATIC S7-1200 CPU - Cross-Site Scripting author:...

4.3CVSS6.2AI score0.2095EPSS
Exploits3References5
Nuclei
Nuclei
added yesterday45 views

SINEMA Remote Connect Server < V2.0 - Open Redirect

A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0. Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks. id: CVE-2022-23102...

6.1CVSS6.3AI score0.05265EPSS
Exploits2References5
Tenable Nessus
Tenable Nessus
added 2026/07/06 12:0 a.m.9 views

Siemens SENTRON 7KT PAC1261 HTTP Request/Response Smuggling (CVE-2025-22871)

The Go net/http package incorrectly treats a bare line feed LF as a valid line terminator in chunked transfer data. This flaw can permit request smuggling if a net/http server is used in conjunction with a server that incorrectly accepts a bare LF as a line terminator. This plugin only works with...

9.1CVSS6.8AI score0.00778EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/07/06 12:0 a.m.8 views

Siemens SIMATIC S7 PLC Web Server Improper Neutralization of Input During Web Page Generation (CVE-2026-25787)

Affected devices do not properly validate and sanitize Technology Object TO name rendered on the 'Motion Control Diagnostics' page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the...

9.3CVSS7.2AI score0.0037EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/07/06 12:0 a.m.8 views

Siemens SIMATIC S7 PLC Web Server Improper Neutralization of Input During Web Page Generation (CVE-2026-25789)

Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote attacker to social engineer the user into selecting a modified firmware file. This would result in malicious JavaScript execution in the context of the authenticated user's...

7.2CVSS7.3AI score0.00274EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/07/06 12:0 a.m.7 views

Siemens SIMATIC S7 PLC Web Server Improper Neutralization of Input During Web Page Generation (CVE-2026-25786)

Affected devices do not properly validate and sanitize PLC/station name rendered on the 'communication' parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a...

9.3CVSS7.2AI score0.0037EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.6 views

Siemens RuggedCom Rox Out-of-bounds Read (CVE-2019-14197)

An issue was discovered in Das U-Boot through 2019.07. There is a read of out-of-bounds data at nfsreadreply. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...

9.1CVSS6.7AI score0.02368EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.8 views

Siemens RUGGEDCOM RST2428P Path Traversal (CVE-2025-7039)

A flaw was found in glib. An integer overflow during temporary file creation leads to an out-of-bounds memory access, allowing an attacker to potentially perform path traversal or access private temporary file content by creating symbolic links. This vulnerability allows a local attacker to...

3.7CVSS5.8AI score0.0037EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.5 views

Siemens RUGGEDCOM RST2428P Integer Overflow or Wraparound (CVE-2025-13601)

A heap-based buffer overflow problem was found in glib through an incorrect calculation of buffer size in the gescapeuristring function. If the string to escape contains a very large number of unacceptable characters which would need escaping, the calculation of the length of the escaped string...

7.7CVSS6.9AI score0.00306EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.5 views

Siemens RuggedCom Rox Out-of-bounds Write (CVE-2022-30790)

Das U-Boot 2022.01 has a Buffer Overflow, a different issue than CVE-2022-30552. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid505465;...

7.8CVSS6.9AI score0.00554EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.7 views

Siemens RUGGEDCOM RST2428P Improper Input Validation (CVE-2025-71190)

In the Linux kernel, the following vulnerability has been resolved: dmaengine: bcm-sba-raid: fix device leak on probe Make sure to drop the reference taken when looking up the mailbox device during probe on probe failures and on driver unbind. This plugin only works with Tenable.ot. Please visit...

5.5CVSS5.7AI score0.00183EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.9 views

Siemens RUGGEDCOM RST2428P Out-of-bounds Write (CVE-2026-1484)

A flaw was found in the GLib Base64 encoding routine when processing very large input data. Due to incorrect use of integer types during length calculation, the library may miscalculate buffer boundaries. This can cause memory writes outside the allocated buffer. Applications that process untrust...

4.2CVSS6AI score0.00304EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.5 views

Siemens RUGGEDCOM RST2428P Authentication Bypass by Primary Weakness (CVE-2026-3784)

curl would wrongly reuse an existing HTTP proxy connection doing CONNECT to a server, even if the new request uses different credentials for the HTTP proxy. The proper behavior is to create or use a separate connection. This plugin only works with Tenable.ot. Please visit...

6.5CVSS7.1AI score0.00302EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.8 views

Siemens RUGGEDCOM RST2428P Integer Overflow or Wraparound (CVE-2026-25210)

In libexpat before 2.7.4, the doContent function does not properly determine the buffer size bufSize because there is no integer overflow check for tag buffer reallocation. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...

7.8CVSS6.9AI score0.00193EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.6 views

Siemens RuggedCom Rox Out-of-bounds Write (CVE-2019-14195)

An issue was discovered in Das U-Boot through 2019.07. There is an unbounded memcpy with unvalidated length at nfsreadlinkreply in the else block after calculating the new path length. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

9.8CVSS6.8AI score0.0235EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.9 views

Siemens RuggedCom Rox Out-of-bounds Write (CVE-2019-14204)

An issue was discovered in Das U-Boot through 2019.07. There is a stack-based buffer overflow in this nfshandler reply helper function: nfsumountallreply. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...

9.8CVSS7.6AI score0.02488EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.3 views

Siemens RuggedCom Rox Out-of-bounds Write (CVE-2019-14203)

An issue was discovered in Das U-Boot through 2019.07. There is a stack-based buffer overflow in this nfshandler reply helper function: nfsmountreply. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...

9.8CVSS7.6AI score0.02488EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.10 views

Siemens RUGGEDCOM RST2428P Improper Input Validation (CVE-2025-40214)

In the Linux kernel, the following vulnerability has been resolved: afunix: Initialise sccindex in unixaddedge. Quang Le reported that the AFUNIX GC could garbage-collect a receive queue of an alive in-flight socket, with a nice repro. The repro consists of three stages. 1 1-a. Create a single...

5.7AI score0.00171EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.7 views

Siemens RUGGEDCOM RST2428P Improper Input Validation (CVE-2026-23236)

In the Linux kernel, the following vulnerability has been resolved: fbdev: smscufx: properly copy ioctl memory to kernelspace The UFXIOCTLREPORTDAMAGE ioctl does not properly copy data from userspace to kernelspace, and instead directly references the memory, which can cause problems if invalid...

7.3CVSS5.7AI score0.00206EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2026/06/18 12:0 a.m.6 views

Siemens RuggedCom Rox Integer Overflow or Wraparound (CVE-2024-57258)

Integer overflows in memory allocation in Das U-Boot before 2025.01-rc1 occur for a crafted squashfs filesystem via sbrk, via request2size, or because ptrdifft is mishandled on x8664. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

7.8CVSS7.2AI score0.00233EPSS
Exploits0References3
Rows per page