Lucene search
+L

12132 matches found

Kitploit
Kitploit
•added 2026/11/19 1:13 p.m.•40 views

ICSSecurityScripts

ICSSecurityScripts Industrial Security Scripts Beckhoff-CX9020-WebControl.py: Controlling the Beckhoff CX9020 Windows CE PLC FullBeckhoffScan.py: Elaborate script for scanning AND hacking Beckhoff PLCs PhoenixControlPLC-ILC150.py: Print out CPU status and reverts it, tested and working on ILC150 ...

6.1AI score
SaveExploits0
Kitploit
Kitploit
•added 2026/11/19 11:30 a.m.•179 views

fluffi

FLUFFI FLUFFI - A distributed evolutionary binary fuzzer for pentesters. About the project High level overview Beginner Tutorial Getting started Usage HOWTOs Technical Details Contributing to FLUFFI LICENSE Bugs found So far, FLUFFI was almost exclusively used on SIEMENS products and solutions...

5.3CVSS7.5AI score0.04116EPSS
SaveExploits0References9
Kitploit
Kitploit
•added 2026/11/19 4:48 a.m.•45 views

CVE-2026-41551

CVE-2026-41551 Reproduction Vulnerability: Siemens ROS fileserver / fileserver2 service relative path traversal CVSS v3.1: 9.1 AV:N / AC:L / PR:N / UI:N / S:U / C:H / I:H / A:N Affected versions: ros-sharp all name.substr10; // remove "package://" std::string package = address.substr0,...

9.3CVSS8.2AI score0.00487EPSS
SaveExploits0
Kitploit
Kitploit
•added 2026/11/19 3:26 a.m.•29 views

Stuxnet

Repository Premise Thank you like this repository. Its value lies in freeing people from having to read dull, scattered reports that run to thousands of pages, which consume a huge amount of time and energy. This repository is highly readable; it does not blindly chase the original version but is...

6.3AI score
SaveExploits0
Nuclei
Nuclei
•added 2026/11/19 2:03 a.m.•64 views

SINEMA Remote Connect Server < V2.0 - Open Redirect

A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0. Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks. id: CVE-2022-23102...

6.1CVSS6AI score0.04718EPSS
SaveExploits2References5
Nuclei
Nuclei
•added 2026/11/19 2:03 a.m.•108 views

Siemens SIMATIC S7-1200 CPU - Cross-Site Scripting

A cross-site scripting vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. id: CVE-2014-2908 info: name: Siemens SIMATIC S7-1200 CPU - Cross-Site Scripting author:...

4.3CVSS6AI score0.20862EPSS
SaveExploits4References5
Kitploit
Kitploit
•added 2026/11/18 11:30 a.m.•9 views

node-red-scanner

node-red-scanner Local triage for CVE-2026-58115, the 10.0 missing-authentication flaw in Node-RED on Siemens SIMATIC IoT2050 Advanced gateways. Give it an Industrial OS version you own, or a settings.js file you own, and it tells you whether that install is still open. It never touches the...

10CVSS9.2AI score0.0089EPSS
SaveExploits2
Kitploit
Kitploit
•added 2026/11/17 2:02 p.m.•39 views

CVE-2015-5374-DoS-PoC

CVE-2015-5374 Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module CVE-2015-5374 Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Module ... Done, say goodbye! Metasploit Module This module sends a specially crafted packet to Port 50000/UDP could cause a denial of service of the...

7.8CVSS8.2AI score0.74497EPSS
SaveExploits7
Kitploit
Kitploit
•added 2026/11/17 1:01 p.m.•37 views

APOLOGEE

🌀 APOLOGEE - Siemens Field Panel Scanner: APOLOGEE is a Python script and Metasploit module that enumerates a hidden directory on Siemens APOGEE PXC BACnet Automation Controllers all versions prior to V3.5 and TALON TC BACnet Automation Controllers all versions prior to V3.5. With a 7.5 CVSS, thi...

5.3CVSS6.6AI score0.08194EPSS
SaveExploits4References1
NCSC
NCSC
•added 2026/11/11 10:15 a.m.•17 views

Vulnerabilities fixed in Siemens products

Siemens has addressed vulnerabilities in various products such as SIMATIC and COMOS. These vulnerabilities allow malicious actors to carry out attacks that may result in the following types of damage: - Denial-of-Service DoS - Manipulation, alteration, or deletion of data - Bypassing of security...

9.8CVSS7.9AI score0.8237EPSS
SaveExploits62References10
GithubExploit
GithubExploit
•added 2026/11/03 4:17 a.m.•32 views

Exploit for CVE-2026-58115

node-red-scanner Local triage for CVE-2026-58115, the 10...

10CVSS9.1AI score0.0089EPSS
SaveExploits2
Positive Technologies
Positive Technologies
•added 2026/11/03 12:00 a.m.•16 views

PT-2026-136029

Name of the Vulnerable Software and Affected Versions Siemens RUGGEDCOM CROSSBOW affected versions not specified Description The PFI plugin framework deployment routine fails to validate path components during the extraction of archive entries to the local plugin repository. Because archive entri...

8.6CVSS6.1AI score0.0019EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2026/10/30 12:00 a.m.•22 views

Siemens Software Center < 4.0.9.8 DLL Sideloading (SSA-580366)

The version of Siemens Software Center installed on the remote Windows host is prior to 4.0.9.8. It is, therefore, affected by a vulnerability as referenced in the SSA-580366 advisory. - A vulnerability has been identified in Siemens Software Center All versions V4.0.9.8. The affected application...

8.4CVSS7.5AI score0.00967EPSS
SaveExploits0References3
ICS
ICS
•added 2026/10/30 12:00 a.m.•13 views

Siemens RUGGEDCOM APE1808

SUMMARY Palo Alto Networks has published 1 information on a vulnerability in PAN-OS related to the Node2Shell vulnerability. This advisory lists the related Siemens Industrial products affected by this vulnerability. Customers are advised to consult and implement the workarounds provided in Palo...

9.8CVSS7.9AI score0.8237EPSS
SaveExploits62References10
ICS
ICS
•added 2026/10/30 12:00 a.m.•17 views

Siemens Industrial Edge Management

SUMMARY Siemens is currently assessing the impact of Node2Shell CVE-2026-111497 on Industrial Edge. Please check your Industrial Edge Management IEM setup: - No Management Applications installed: No action is required. Although the affected Brotli library is included in the IEM software stack,...

9.8CVSS7.9AI score0.8237EPSS
SaveExploits62References10
ICS
ICS
•added 2026/10/30 12:00 a.m.•17 views

Siemens Desigo, Gridscale

SUMMARY On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as "Node2Shell" tracked as CVE-2026-111497. The vulnerability is an out-of-bounds write that could allow a remote...

9.8CVSS8.4AI score0.8237EPSS
SaveExploits62References10
GithubExploit
GithubExploit
•added 2026/10/28 6:15 p.m.•27 views

Exploit for Improper Input Validation in Siemens 6Bk1602-0Aa12-0Tp0_Firmware

Threat Intelligence & Log4Shell Vulnerability Analysis Pro...

10CVSS8.1AI score0.99999EPSS
SaveExploits402
GithubExploit
GithubExploit
•added 2026/10/27 5:44 p.m.•30 views

Exploit for Improper Input Validation in Siemens 6Bk1602-0Aa12-0Tp0_Firmware

EHAX Open House — Log4Shell Demo Kit A safe, self-contained d...

10CVSS7.9AI score0.99999EPSS
SaveExploits402
CNNVD
CNNVD
•added 2026/10/26 12:00 a.m.•18 views

Siemens Mendix SAML authorization issue vulnerability

The Siemens Mendix SAML vulnerability stems from improper protection against SAML assertion replay during authentication processes initiated by an IdP. This may allow unauthenticated remote attackers to gain unauthorized access to the application by replaying valid SAML responses...

7.6CVSS6.8AI score0.00259EPSS
SaveExploits0References1
ICS
ICS
•added 2026/10/26 12:00 a.m.•19 views

Siemens Mendix SAML Module

SUMMARY Mendix SAML module contains an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain unauthorized access by replaying a valid SAML assertion in IdP-initiated authentication flows. Siemens has released new versions for the affected products and...

7.6CVSS6.7AI score0.00259EPSS
SaveExploits0References10
Rows per page