Lucene search

K

Philips Security Vulnerabilities

cve
cve

CVE-2013-2808

Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote att...

8.4AI Score

0.002EPSS

2022-10-03 04:15 PM
27
cve
cve

CVE-2015-2882

Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor ad...

9.8CVSS

9.6AI Score

0.007EPSS

2017-04-10 03:59 AM
24
cve
cve

CVE-2015-2883

Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.

5.4CVSS

5.5AI Score

0.001EPSS

2017-04-10 03:59 AM
25
cve
cve

CVE-2015-2884

Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.

7.5CVSS

7.2AI Score

0.006EPSS

2017-04-10 03:59 AM
18
cve
cve

CVE-2017-14111

The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.

7.2CVSS

7AI Score

0.002EPSS

2017-11-17 08:29 PM
27
cve
cve

CVE-2017-14797

Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on...

7.5CVSS

7.4AI Score

0.003EPSS

2017-10-01 01:29 AM
26
cve
cve

CVE-2017-3210

Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution. A number of applications developed using the Portrait Displays SDK do not use secure permissions when running. These applications run the compo...

7.8CVSS

7.6AI Score

0.0004EPSS

2018-07-24 03:29 PM
24
cve
cve

CVE-2017-9654

The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.

8.8CVSS

8.6AI Score

0.002EPSS

2018-04-24 03:29 PM
22
cve
cve

CVE-2017-9656

The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated ...

9.1CVSS

9.2AI Score

0.002EPSS

2018-04-24 03:29 PM
21
cve
cve

CVE-2017-9657

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, an...

6.5CVSS

6.2AI Score

0.001EPSS

2018-04-30 03:29 PM
25
cve
cve

CVE-2017-9658

Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this stat...

6.5CVSS

6.5AI Score

0.001EPSS

2018-04-30 03:29 PM
25
cve
cve

CVE-2018-10597

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that...

8.3CVSS

8.1AI Score

0.001EPSS

2018-06-05 08:29 PM
28
cve
cve

CVE-2018-10599

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that...

5.3CVSS

5.2AI Score

0.001EPSS

2018-06-05 08:29 PM
24
cve
cve

CVE-2018-10601

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that...

8.2CVSS

8.2AI Score

0.001EPSS

2018-06-05 08:29 PM
25
cve
cve

CVE-2018-14787

In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with loc...

7.8CVSS

7.8AI Score

0.0004EPSS

2018-08-22 06:29 PM
27
cve
cve

CVE-2018-14789

In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges.

6.7CVSS

7AI Score

0.0004EPSS

2018-08-22 06:29 PM
31
cve
cve

CVE-2018-14799

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.

3.7CVSS

4.6AI Score

0.001EPSS

2018-08-22 06:29 PM
25
cve
cve

CVE-2018-14801

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset exi...

6.2CVSS

6.2AI Score

0.001EPSS

2018-08-22 06:29 PM
28
cve
cve

CVE-2018-14803

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to t...

5.3CVSS

4.8AI Score

0.001EPSS

2018-09-26 07:29 PM
23
cve
cve

CVE-2018-17906

Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system.

8.8CVSS

8.6AI Score

0.001EPSS

2018-11-19 08:29 PM
24
cve
cve

CVE-2018-19001

Philips HealthSuite Health Android App, all versions. The software uses simple encryption that is not strong enough for the level of protection required.

4.3CVSS

4.7AI Score

0.001EPSS

2018-12-07 02:29 PM
25
cve
cve

CVE-2018-5438

Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mo...

6.3CVSS

6.3AI Score

0.001EPSS

2018-03-20 05:29 PM
35
cve
cve

CVE-2018-5451

In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers w...

9.8CVSS

9.5AI Score

0.003EPSS

2018-03-28 05:29 PM
21
cve
cve

CVE-2018-5454

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime.

8.1CVSS

8.2AI Score

0.008EPSS

2018-03-26 02:29 PM
18
cve
cve

CVE-2018-5458

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability using SSL legacy encryption that could allow an attacker to gain unauthorized access to resources and information.

7.5CVSS

7.6AI Score

0.001EPSS

2018-03-26 02:29 PM
24
cve
cve

CVE-2018-5462

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an SSL incorrect hostname certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.

7.5CVSS

7.6AI Score

0.001EPSS

2018-03-26 02:29 PM
22
cve
cve

CVE-2018-5464

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an untrusted SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.

7.5CVSS

7.6AI Score

0.001EPSS

2018-03-26 02:29 PM
28
cve
cve

CVE-2018-5466

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a self-signed SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.

7.5CVSS

7.6AI Score

0.001EPSS

2018-03-26 02:29 PM
22
cve
cve

CVE-2018-5468

Philips Intellispace Portal all versions 7.0.x and 8.0.x have a remote desktop access vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code

9.8CVSS

9.8AI Score

0.008EPSS

2018-03-26 02:29 PM
29
cve
cve

CVE-2018-5470

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an unquoted search path or element vulnerability that has been identified, which may allow an authorized local user to execute arbitrary code and escalate their level of privileges.

7.8CVSS

8.5AI Score

0.0004EPSS

2018-03-26 02:29 PM
22
cve
cve

CVE-2018-5472

Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code.

9.8CVSS

9.8AI Score

0.008EPSS

2018-03-26 02:29 PM
26
cve
cve

CVE-2018-5474

Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash.

9.8CVSS

9.6AI Score

0.041EPSS

2018-03-26 02:29 PM
18
cve
cve

CVE-2018-7498

In Philips Alice 6 System version R8.0.2 or prior, the lack of proper data encryption passes up the guarantees of confidentiality, integrity, and accountability that properly implemented encryption conveys.

9.8CVSS

9.4AI Score

0.002EPSS

2018-03-28 05:29 PM
22
cve
cve

CVE-2018-7580

Philips Hue is vulnerable to a Denial of Service attack. Sending a SYN flood on port tcp/80 will freeze Philips Hue's hub and it will stop responding. The "hub" will stop operating and be frozen until the flood stops. During the flood, the user won't be able to turn on/off the lights, and all of th...

7.5CVSS

7.4AI Score

0.015EPSS

2020-12-21 09:15 PM
54
2
cve
cve

CVE-2018-8842

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to ...

8.8CVSS

8.1AI Score

0.001EPSS

2018-09-26 07:29 PM
22
cve
cve

CVE-2018-8844

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.

8.8CVSS

8.5AI Score

0.002EPSS

2018-09-26 07:29 PM
18
cve
cve

CVE-2018-8846

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.

6.1CVSS

5.8AI Score

0.001EPSS

2018-09-26 07:29 PM
22
cve
cve

CVE-2018-8848

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.

7.5CVSS

7.4AI Score

0.002EPSS

2018-09-26 07:29 PM
21
cve
cve

CVE-2018-8850

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result ...

9.8CVSS

9.4AI Score

0.01EPSS

2018-09-26 07:29 PM
21
cve
cve

CVE-2018-8852

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier.

8.8CVSS

8.3AI Score

0.003EPSS

2018-09-26 07:29 PM
20
cve
cve

CVE-2018-8853

Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brillia...

8.8CVSS

8.5AI Score

0.001EPSS

2018-05-04 05:29 PM
27
cve
cve

CVE-2018-8854

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended.

7.5CVSS

7.3AI Score

0.003EPSS

2018-09-26 07:29 PM
21
cve
cve

CVE-2018-8856

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.

9.8CVSS

9.3AI Score

0.003EPSS

2018-09-26 07:29 PM
21
cve
cve

CVE-2018-8857

Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbou...

7.8CVSS

7.8AI Score

0.001EPSS

2018-05-04 05:29 PM
38
cve
cve

CVE-2018-8861

Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized atta...

8.7CVSS

8.4AI Score

0.001EPSS

2018-05-04 05:29 PM
26
cve
cve

CVE-2018-8863

The HTTP header in Philips EncoreAnywhere contains data an attacker may be able to use to gain sensitive information.

7.5CVSS

7.5AI Score

0.001EPSS

2023-11-09 11:15 PM
16
cve
cve

CVE-2019-10968

Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.

4.4CVSS

4.8AI Score

0.0004EPSS

2019-07-24 03:15 PM
97
cve
cve

CVE-2019-10988

In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited...

3.4CVSS

4.1AI Score

0.0004EPSS

2019-09-04 02:15 PM
48
cve
cve

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker c...

7.2CVSS

7AI Score

0.001EPSS

2019-09-12 08:15 PM
119
cve
cve

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product d...

7.2CVSS

7.1AI Score

0.001EPSS

2019-09-12 08:15 PM
116
Total number of security vulnerabilities101