833 matches found
CVE-2013-0679
CVE-2013-0679 concerns Siemens WinCC Web Server: a Relative Path Traversal vulnerability that allows remote authenticated users to read arbitrary files by crafting a URL pathname. Affected products include WinCC prior to 7.2 (and SIMATIC PCS7 prior to 8.0 SP1); the issue arises in the Web server ...
CVE-2013-0675
CVE-2013-0675 describes a remote buffer overflow in the CCEServer (central communications component) of Siemens WinCC prior to version 7.2, used in SIMATIC PCS7 prior to 8.0 SP1. A crafted packet to a dynamically assigned port can trigger a DoS condition on WinCC. Affected software is WinCC with ...
CVE-2013-0679
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname...
CVE-2013-0678
Siemens WinCC (before 7.2, used in SIMATIC PCS7 before 8.0 SP1) stores WebNavigator passwords in an MS SQL database without proper protection, enabling remote authenticated users with DB access to read credentials and obtain sensitive information. The root cause is information disclosure due to m...
CVE-2013-0674
Siemens WinCC RegReader ActiveX Control vulnerability (CVE-2013-0674) affects WinCC prior to 7.2 and SIMATIC PCS7 prior to 8.0 SP1. A stack-based buffer overflow in RegReader can be triggered via a long parameter in the ActiveX control, potentially allowing remote code execution in the user’s bro...
CVE-2013-0675
Buffer overflow in CCEServer aka the central communications component in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet...
CVE-2013-0672
Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data...
CVE-2013-0669
The HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to cause a denial of service daemon crash via a crafted HTTP request...
CVE-2013-0668
Multiple cross-site scripting XSS vulnerabilities in the HMI web application in Siemens WinCC TIA Portal 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL...
CVE-2013-0667
Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL...
CVE-2013-0670
CRLF injection vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL...
CVE-2011-4515
Siemens WinCC TIA Portal 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging 1 physical access or 2 Sm@rt Server access...
CVE-2013-0671
Directory traversal vulnerability in Siemens WinCC TIA Portal 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL...
Cross site request forgery (csrf)
The HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to cause a denial of service daemon crash via a crafted HTTP request...
Cross site scripting
Multiple cross-site scripting XSS vulnerabilities in the HMI web application in Siemens WinCC TIA Portal 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL...
Design/Logic Flaw
Siemens WinCC TIA Portal 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging 1 physical access or 2 Sm@rt Server access...
Cross site scripting
Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data...
Directory traversal
Directory traversal vulnerability in Siemens WinCC TIA Portal 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL...
Cross site scripting
Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL...
Crlf injection
CRLF injection vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL...