Siemens WinCC TIA Portal Vulnerabilities
OVERVIEW Researchers Timur Yunusov and Sergey Bobrov of Positive Technologies have identified several vulnerabilities in the Siemens WinCC TIA Portal. A software update has been produced by Siemens that mitigates these vulnerabilities. Siemens has tested the software update to validate that it...
DHS, ICS-CERT Warn of Siemens HMI Vulnerabilities
The Department of Homeland Security and the ICS-CERT issued an advisory yesterday warning of serious vulnerabilities in Siemens industrial control software deployed in a number of industries including water, gas and oil, and chemical. Siemens said it has patched the flaws in a new version of its...
CVE-2013-0678
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query...
CVE-2013-0677
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file...
CVE-2013-0679
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname...
CVE-2013-0675
Buffer overflow in CCEServer aka the central communications component in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet...
CVE-2013-0674
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter...
CVE-2013-0676
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query...
Design/Logic Flaw
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file...
Information disclosure
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query...
Directory traversal
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname...
Information disclosure
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query...
Buffer overflow
Buffer overflow in CCEServer aka the central communications component in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet...
Buffer overflow
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter...
CVE-2013-0676
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query...
CVE-2013-0677
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file...
CVE-2013-0677
The CVE-2013-0677 issue affects Siemens WinCC (pre-7.2) used in SIMATIC PCS7 pre-8.0 SP1 and related products. A crafted project file can allow remote attackers to access sensitive information or cause a DoS via the WinCC web server component. The root cause is improper handling of crafted projec...
CVE-2013-0674
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter...
CVE-2013-0676
Siemens WinCC (before 7.2; in SIMATIC PCS7 before 8.0 SP1) stores WebNavigator credentials in an MS SQL database and fails to properly restrict privileges. This Improper Authorization allows remote authenticated users to read sensitive data via SQL queries. Impact includes exposure of credentials...
CVE-2013-0678
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query...