19888 matches found
ROS-20220125-02
Nginx web server vulnerability is related to a logical error in TLS implementation when working with different protocols but using compatible certificates, such as multi-domain or wildcard certificates. certificates. Exploitation of the vulnerability could allow an attacker acting remotely to...
nginx:1.20 security update
An update is available for nginx. This update affects Rocky Linux 8. A Common Vulnerability Scoring System CVSS base score, which gives a detailed severity rating, is available for each vulnerability from the CVE list nginx is a web and proxy server supporting HTTP and other protocols, with a foc...
CVE-2022-21236
An information disclosure vulnerability exists due to a web server misconfiguration in the Reolink RLC-410W v3.0.0.13620121102. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability...
CVE-2022-21236
An information disclosure vulnerability exists due to a web server misconfiguration in the Reolink RLC-410W v3.0.0.13620121102. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability...
CVE-2021-40338
Hitachi Energy LinkOne product, has a vulnerability due to a web server misconfiguration, that enables debug mode and reveals the full path of the filesystem directory when an attacker generates errors during a query operation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24;...
CVE-2021-40338
Hitachi Energy LinkOne product, has a vulnerability due to a web server misconfiguration, that enables debug mode and reveals the full path of the filesystem directory when an attacker generates errors during a query operation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24;...
CVE-2021-22820
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4...
CVE-2021-22822
A CWE-79 Improper Neutralization of Input During Web Page Generation �Cross-site Scripting� vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the chargi...
CVE-2021-22820
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4...
CVE-2021-22820
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4...
CVE-2021-22725
A CVE-352 Cross-Site Request Forgery CSRF vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22...
Path traversal
Hitachi Energy LinkOne product, has a vulnerability due to a web server misconfiguration, that enables debug mode and reveals the full path of the filesystem directory when an attacker generates errors during a query operation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24;...
Cross site scripting
A CWE-79 Improper Neutralization of Input During Web Page Generation ?Cross-site Scripting? vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the chargi...
Information disclosure
An information disclosure vulnerability exists due to a web server misconfiguration in the Reolink RLC-410W v3.0.0.13620121102. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability...
CVE-2022-21236
An information disclosure vulnerability exists due to a web server misconfiguration in the Reolink RLC-410W v3.0.0.13620121102. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability...
CVE-2022-21236
The CVE-2022-21236 issue affects Reolink RLC-410W (v3.0.0.136_20121102). A web server misconfiguration (nginx) exposes the TLS private key from the document root, enabling potential impersonation of the camera and, in some contexts, decryption of HTTPS traffic to steal an admin session token. Thi...
CVE-2021-40338
Hitachi Energy LinkOne WebView is affected by CVE-2021-40338 due to a web server misconfiguration that enables debug mode and reveals the full filesystem directory path when errors occur during a query. Affected versions are LinkOne WebView 3.20, 3.22, 3.23, 3.24, 3.25, and 3.26. The issue can di...
CVE-2021-40338 OWASP Related Vulnerabilities in Hitachi Energy’s LinkOne Product
Hitachi Energy LinkOne product, has a vulnerability due to a web server misconfiguration, that enables debug mode and reveals the full path of the filesystem directory when an attacker generates errors during a query operation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24;...
CVE-2021-22822
CVE-2021-22822 affects Schneider Electric EVlink family (City EVC1S22P4 / EVC1S7P4, Parking EVW2/EVF2/EVP2PE, Smart Wallbox EVB1A) with all versions prior to R8 V3.4.0.2. It is a CWE-79 Cross-site Scripting issue arising from improper neutralization of input during web page generation, enabling a...
CVE-2021-22822
A CWE-79 Improper Neutralization of Input During Web Page Generation �Cross-site Scripting� vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the chargi...