Siemens SICAM A8000 RTUs Protection Mechanism Failure (CVE-2020-28396)
A vulnerability has been identified in SICAM A8000 CP-8000 All versions V16, SICAM A8000 CP-8021 All versions V16, SICAM A8000 CP-8022 All versions V16. A web server misconfiguration of the affected device can cause insecure ciphers usage by a users browser. An attacker in a privileged position...
Siemens APOGEE and TALON Buffer Copy Without Checking Size of Input (CVE-2021-27391)
A vulnerability has been identified in APOGEE MBC PPC P2 Ethernet All versions = V2.6.3, APOGEE MEC PPC P2 Ethernet All versions = V2.6.3, APOGEE PXC Compact BACnet All versions = V2.8, APOGEE PXC Modular BACnet All versions = V2.8, TALON TC Compact BACnet All versions V3.5.3, TALON TC Modular...
Schneider Electric Web Server on Modicon M340 Out-of-Bounds Read (CVE-2020-7562)
A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file ...
Rockwell Automation MicroLogix Incorrect Permission Assignment for Critical Resource (CVE-2016-9338)
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD,...
Siemens SIPROTEC Information Disclosure (CVE-2016-4785)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens SICAM MMU, SICAM T, and SICAM SGU Improper Neutralization of Script-Related HTML Tags in a Web Page (CVE-2020-10043)
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. The web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked into accessing a malicious link. This plugin only works with Tenable.ot. Please...
Siemens SICAM MMU, SICAM T, and SICAM SGU Out-of-Bounds Read (CVE-2020-10037)
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information. This...
Siemens SIMATIC S7-1200 HTTP Response Splitting (CVE-2014-2908)
Cross-site scripting XSS vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC Cross-site Scripting (CVE-2012-3040)
Cross-site scripting XSS vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Rockwell Automation Allen-Bradley CompactLogix Reflective Cross-Site Scripting (CVE-2016-2279)
Cross-site scripting XSS vulnerability in the web server in Rockwell Automation Allen-Bradley CompactLogix 1769-L before 28.011+ allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. This plugin only works with Tenable.ot. Please visit...
Rockwell Automation MicroLogix Cross-site Scripting (CVE-2015-6488)
Cross-site scripting XSS vulnerability in the web server on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. This plugin only works with Tenable.ot. Please visit...
Siemens EN100 Ethernet Module Relative Path Traversal (CVE-2019-13944)
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
Schneider Electric Web Server on Modicon M340 Out-of-Bounds Write (CVE-2020-7563)
A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause corruption of data, a crash, or code execution when uploading a specially crafted...
Siemens SIMATIC CP 343-1/CP 443-1 Modules and SIMATIC S7-300/S7-400 CPUs (CVE-2016-8673)
A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...
Siemens SIMATIC S7 Uncontrolled Resource Consumption (CVE-2019-13940)
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU All versions V3.X.17, SIMATIC ET 200pro IM154-8F PN/DP CPU All versions V3.X.17, SIMATIC ET 200pro IM154-8FX PN/DP CPU All versions V3.X.17, SIMATIC ET 200S IM151-8 PN/DP CPU All versions V3.X.17, SIMATIC ET 200S IM151-8F...
CVE-2022-22987
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions...
CVE-2022-22987
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions...
CVE-2021-21963
An information disclosure vulnerability exists in the Web Server functionality of Sealevel Systems, Inc. SeaConnect 370W v1.3.34. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information. An attacker can perform a man-in-the-middle attack to trigger this...
CVE-2020-7534
A CWE-352: Cross-Site Request Forgery CSRF vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in. Affected Products: Modicon M340 CPUs: BMXP34 All Versions, Modicon Quantum CPUs with...
Hardcoded credentials
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions...