960 matches found
kernel: ipvlan: add ipvlan_route_v6_outbound() helper
In the Linux kernel, the following vulnerability has been resolved: ipvlan: add ipvlanroutev6outbound helper Inspired by syzbot reports using a stack of multiple ipvlan devices. Reduce stack size needed in ipvlanprocessv6outbound by moving the flowi6 struct used for the route lookup in an non...
CVE-2024-4353 Stored XSS in Generate Board Name Input Field
Concrete CMS versions 9.0.0 through 9.3.2 are affected by a stored XSS vulnerability in the generate dashboard board instance functionality. The Name input field does not check the input sufficiently letting a rogue administrator have the capability to inject malicious JavaScript code. The Concre...
CVE-2024-4353
Concrete CMS versions 9.0.0–9.3.2 are affected by a stored XSS in the generate dashboard board instance functionality. The Name input field allows injection of JavaScript because input is not sufficiently validated, enabling a rogue administrator to execute code. Affected product: Concrete CMS (v...
Johnson Controls exacqVision client and exacqVision server
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.0 ATTENTION : Exploitable remotely Vendor : Johnson Controls Inc. Equipment : exacqVision Client, exacqVision Server key Vulnerability : Inadequate Encryption Strength 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker...
Rockwell Automation Logix Controllers
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Rockwell Automation Equipment : ControlLogix, GuardLogix, and 1756 ControlLogix I/O Modules Vulnerability : Unprotected Alternate Channel 2. RISK EVALUATION Successful exploitation of this...
AVTECH IP camera
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity/public exploits are available/known public exploitation Vendor : AVTECH SECURITY Corporation Equipment : IP camera Vulnerability : Command Injection 2. RISK EVALUATION Successful exploitation of this...
CVE-2024-42081
In the Linux kernel, the following vulnerability has been resolved: drm/xe/xedevcoredump: Check NULL before assignments Assign 'xedevcoredumpsnapshot ' and 'xedevice ' only if 'coredump' is not NULL. v2 - Fix commit messages. v3 - Define variables before code.Ashutosh/Jose v4 - Drop return check...
DEBIAN-CVE-2024-41022
In the Linux kernel, the following vulnerability has been resolved: drm/amdgpu: Fix signedness bug in sdmav40processtrapirq The "instance" variable needs to be signed for the error handling to work...
UBUNTU-CVE-2024-41022
In the Linux kernel, the following vulnerability has been resolved: drm/amdgpu: Fix signedness bug in sdmav40processtrapirq The "instance" variable needs to be signed for the error handling to work...
CVE-2024-33365: Buffer Copy without Checking Size of Input
Buffer Overflow vulnerability in Tenda AC10 v4 USAC10V4.0siV16.03.10.20cn allows a remote attacker to execute arbitrary code via the VirtualDataCheck function in the bin/httpd component...
CVE-2024-33365
Buffer Overflow vulnerability in Tenda AC10 v4 USAC10V4.0siV16.03.10.20cn allows a remote attacker to execute arbitrary code via the VirtualDataCheck function in the bin/httpd component...
National Instruments IO Trace
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION : Low attack complexity Vendor : National Instruments Equipment : IO Trace Vulnerability : Stack-Based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker to execute arbitrary code. 3...
National Instruments LabVIEW
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION : Low attack complexity Vendor : National Instruments Equipment : LabVIEW Vulnerabilities : Out-of-Bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of these...
CVE-2024-37066
A command injection vulnerability exists in Wyze V4 Pro firmware versions before 4.50.4.9222, which allows attackers to execute arbitrary commands over Bluetooth as root during the camera setup process...
CVE-2024-37066
A command injection vulnerability exists in Wyze V4 Pro firmware versions before 4.50.4.9222, which allows attackers to execute arbitrary commands over Bluetooth as root during the camera setup process...
CVE-2024-37066
A command injection vulnerability exists in Wyze V4 Pro firmware versions before 4.50.4.9222, which allows attackers to execute arbitrary commands over Bluetooth as root during the camera setup process...
CVE-2024-37066
A command injection vulnerability exists in Wyze V4 Pro firmware versions before 4.50.4.9222, which allows attackers to execute arbitrary commands over Bluetooth as root during the camera setup process...
CVE-2024-37066
Summary: CVE-2024-37066 affects Wyze V4 Pro firmware prior to 4.50.4.9222. The flaw enables an attacker to inject and execute arbitrary commands as root over Bluetooth during the camera setup process. Affected component: Wyze V4 Pro firmware (pre-4.50.4.9222). Root cause/impact: command injection...
CVE-2024-37066: Improper Neutralization of Special Elements used in an OS Command
A command injection vulnerability exists in Wyze V4 Pro firmware versions before 4.50.4.9222, which allows attackers to execute arbitrary commands over Bluetooth as root during the camera setup process...
PT-2024-27282 · Wyze · Wyze V4 Pro
Name of the Vulnerable Software and Affected Versions: Wyze V4 Pro firmware versions prior to 4.50.4.9222 Description: A command injection issue exists, allowing attackers to execute arbitrary commands over Bluetooth as root during the camera setup process. Recommendations: For Wyze V4 Pro firmwa...