Lucene search

K
icsIndustrial Control Systems Cyber Emergency Response TeamICSA-24-214-07
HistoryAug 01, 2024 - 12:00 p.m.

AVTECH IP Camera

2024-08-0112:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
12
avtech security corporation
ip camera
command injection
vulnerability
network
exploitation
firmware
cvss v4
mitigation
cisa
impact analysis
risk assessment
defense-in-depth
cybersecurity
recommended practices
cisa products

CVSS3

9.8

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS4

8.7

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/SC:N/VI:H/SI:N/VA:H/SA:N

AI Score

9.1

Confidence

High

EPSS

0.338

Percentile

97.1%

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7 *ATTENTION: Exploitable remotely/low attack complexity/public exploits are available/known public exploitation
  • Vendor: AVTECH SECURITY Corporation
  • Equipment: IP camera
  • Vulnerability: Command Injection

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to inject and execute commands as the owner of the running process.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following AVTECH IP camera was identified as being affected; it is suspected that prior versions of other IP cameras and NVR (network video recorder) products are also affected:

  • AVM1203: firmware version FullImg-1023-1007-1011-1009 and prior

3.2 Vulnerability Overview

3.2.1COMMAND INJECTION CWE-77

Commands can be injected over the network and executed without authentication.

CVE-2024-7029 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-7029. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Financial Services, Healthcare and Public Health, Transportation Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Larry Cashdollar and Aline Eliovich of Akamai Technologies reported this vulnerability to CISA.
An anonymous third-party organization confirmed Akamai’s report and identified specific affected products and firmware versions.

4. MITIGATIONS

AVTECH SECURITY Corporation has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact AVTECH for additional information.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

5. UPDATE HISTORY

  • August 1, 2024: Initial Publication

References

CVSS3

9.8

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS4

8.7

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/SC:N/VI:H/SI:N/VA:H/SA:N

AI Score

9.1

Confidence

High

EPSS

0.338

Percentile

97.1%