Hardcoded credentials

A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed...

10CVSS7.1AI score0.01563EPSS
SaveExploits0References1Affected Software2
NVD
NVD
added 2018/05/09 1:29 p.m.24 views

CVE-2016-9335

A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed...

10CVSS9.4AI score0.01563EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2018/05/09 1:00 p.m.52 views

CVE-2016-9335

A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed...

9.4AI score0.01563EPSS
SaveExploits0References1
ICS
ICS
added 2018/05/08 12:00 a.m.99 views

Silex Technology SX-500/SD-320AN or GE Healthcare MobileLink (Update B)

1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION : Exploitable Remotely / Low skill level to exploit / Public exploits are available Vendors : Silex Technology, GE Healthcare Equipment : SX-500, SD-320AN, MobileLink Vulnerabilities : Improper Authentication, OS Command Injection 2. UPDATE INFORMATION...

7.4CVSS7.9AI score0.01348EPSS
SaveExploits0References5
Prion
Prion
added 2018/05/04 5:29 p.m.25 views

Input validation

In Lantech IDS 2102 2.0 and prior, nearly all input fields allow for arbitrary input on the device. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H...

10CVSS9.7AI score0.02285EPSS
SaveExploits0References2
Prion
Prion
added 2018/05/04 5:29 p.m.25 views

Stack overflow

In Lantech IDS 2102 2.0 and prior, a stack-based buffer overflow vulnerability has been identified which may allow remote code execution. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H...

10CVSS10AI score0.05736EPSS
SaveExploits0References2
NVD
NVD
added 2018/05/04 5:29 p.m.23 views

CVE-2018-8865

In Lantech IDS 2102 2.0 and prior, a stack-based buffer overflow vulnerability has been identified which may allow remote code execution. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H...

10CVSS10AI score0.05736EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2018/05/04 5:00 p.m.36 views

CVE-2018-8869

In Lantech IDS 2102 2.0 and prior, nearly all input fields allow for arbitrary input on the device. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H...

9.8AI score0.02285EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2018/05/04 5:00 p.m.30 views

CVE-2018-8865

In Lantech IDS 2102 2.0 and prior, a stack-based buffer overflow vulnerability has been identified which may allow remote code execution. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H...

10AI score0.05736EPSS
SaveExploits0References2
CVE
CVE
added 2018/05/04 5:00 p.m.51 views

CVE-2018-8869

CVE-2018-8869 affects Lantech IDS 2102 (versions 2.0 and earlier). The root cause is improper input validation, with nearly all input fields accepting arbitrary data, enabling potential remote code execution on the device. The NVD/NVD-derived CVSSv3 base score is 9.8 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/...

10CVSS9.7AI score0.02285EPSS
SaveExploits0References2Affected Software1
ICS
ICS
added 2018/05/03 12:00 a.m.60 views

ICSA-18-128-02 Siemens Siveillance VMS (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION : Exploitable remotely Vendor : Siemens Equipment : Siveillance Video Management Software VMS Vulnerability : Deserialization of Untrusted Data 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-18-128-02...

8.1CVSS8.3AI score0.04034EPSS
SaveExploits0References9
Exploit DB
Exploit DB
added 2018/05/03 12:00 a.m.54 views

JasperReports - (Authenticated) File Read

TIBCO’s JasperReports string = wrapper.getParameterValues"page" To: getResource @ DirResourceSet.java:101 file = new File/home/rhino/jasperreports...mcat/webapps/jasperserver,"/WEB-INF/jsp/modules/administer/adminImport.jsp" Due to a lack of input validation we found ourselves with the capability...

8.8CVSS7.7AI score0.4963EPSS
SaveExploits3
ICS
ICS
added 2018/05/03 12:00 a.m.63 views

Lantech IDS 2102

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low skill level to exploit. Vendor : Lantech Equipment : IDS 2102 Vulnerabilities : Improper Input Validation, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker...

10CVSS10AI score0.05736EPSS
SaveExploits0References5
ICS
ICS
added 2018/05/03 12:00 a.m.44 views

Siemens Medium Voltage SINAMICS Products (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Siemens Equipment : Medium Voltage SINAMICS Products Vulnerabilities : Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled...

7.4AI score
SaveExploits0References9
NVD
NVD
added 2018/05/01 6:29 p.m.27 views

CVE-2017-14012

Boston Scientific ZOOM LATITUDE PRM Model 3120 does not encrypt PHI at rest. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

4.6CVSS4.8AI score0.00277EPSS
SaveExploits0References2
NVD
NVD
added 2018/05/01 6:29 p.m.27 views

CVE-2017-14014

Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

4.6CVSS4.7AI score0.00393EPSS
SaveExploits0References2
Prion
Prion
added 2018/05/01 6:29 p.m.22 views

Design/Logic Flaw

Boston Scientific ZOOM LATITUDE PRM Model 3120 does not encrypt PHI at rest. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

2.1CVSS4.8AI score0.00277EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2018/05/01 6:00 p.m.38 views

CVE-2017-14012

Boston Scientific ZOOM LATITUDE PRM Model 3120 does not encrypt PHI at rest. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

4.8AI score0.00277EPSS
SaveExploits0References2
Prion
Prion
added 2018/04/30 3:29 p.m.21 views

Stack overflow

Delta PMSoft versions 2.10 and prior have multiple stack-based buffer overflow vulnerabilities where a .ppm file can introduce a value larger than is readable by PMSoft's fixed-length stack buffer. This can cause the buffer to be overwritten, which may allow arbitrary code execution or cause the...

4.6CVSS8.1AI score0.00465EPSS
SaveExploits0References2Affected Software1
Openbugbounty
Openbugbounty
added 2018/04/27 9:18 a.m.16 views

v3.kz XSS vulnerability

Open Bug Bounty ID: OBB-609208 Description| Value ---|--- Affected Website:| v3.kz Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| 6.1...

SaveExploits0
Rows per page
Query Builder