Lucene search

K
icsIndustrial Control Systems Cyber Emergency Response TeamICSA-18-128-02
HistoryMay 24, 2018 - 12:00 p.m.

Siemens Siveillance VMS (Update A)

2018-05-2412:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
41

6.8 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:P/I:P/A:P

8.1 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

HIGH

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

0.056 Low

EPSS

Percentile

93.3%

1. EXECUTIVE SUMMARY

  • CVSS v3 8.1

  • ATTENTION: Exploitable remotely

  • Vendor: Siemens

  • Equipment: Siveillance Video Management Software (VMS)

  • Vulnerability: Deserialization of Untrusted Data

2. UPDATE INFORMATION

This updated advisory is a follow-up to the original advisory titled ICSA-18-128-02 Siemens Siveillance VMS that was published May 8, 2018, on the NCCIC/ICS-CERT website.

3. RISK EVALUATION

Successful exploitation of this vulnerability by the affected ports in .NET Remoting deserialization could allow elevation of privileges and/or cause a denial-of-service.

4. TECHNICAL DETAILS

4.1 AFFECTED PRODUCTS

The following versions of Siveillance VMS, an IP video management software, are affected:

  • Siveillance VMS 2016 R1, all versions prior to V10.0a,
  • Siveillance VMS 2016 R2, all versions prior to V10.1a,
  • Siveillance VMS 2016 R3, all versions prior to V10.2b,
  • Siveillance VMS 2017 R1, all versions prior to V11.1a,
  • Siveillance VMS 2017 R2, all versions prior to V11.2a, and
  • Siveillance VMS 2018 R1, all versions prior to V12.1a.

4.2 VULNERABILITY OVERVIEW

4.2.1 DESERIALIZATION OF UNTRUSTED DATA CWE-502

The Recording Server, Management Server, and Management Client on Ports 6473/TCP local connection only, 7474/TCP, 8966/TCP local connection only, and Port 9993/TCP use an exploitable .NET Framework Remoting deserialization level.

An attacker could exploit this vulnerability by accessing the vulnerable ports, allowing elevation of privileges or causing a denial-of-service; compromising confidentiality, integrity, and availability of the targeted system.

CVE-2018-7891 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

4.3 BACKGROUND

  • Critical Infrastructure Sectors: Unknown
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: Germany

4.4 RESEARCHER

Siemens ProductCERT reported this vulnerability to NCCIC.

5. MITIGATIONS

Siemens has released updates for several affected products and recommends users update to the new version.

--------- Begin Update A Part 1 of 1 --------

  • Siveillance VMS 2016 R1: Update to V10.0a (Obtain the update via the local Siemens representative)
  • Siveillance VMS 2016 R2: Update to V10.1a (Obtain the update via the local Siemens representative)
  • Siveillance VMS 2016 R3: Update to V10.2b (Obtain the update via the local Siemens representative)
  • Siveillance VMS 2017 R1: Update to V11.1a (Obtain the update via the local Siemens representative)
  • Siveillance VMS 2017 R2: Update to V11.2a (Obtain the update via the local Siemens representative)
  • Siveillance VMS 2018 R1: Update to V12.1a (Obtain the update via the local Siemens representative)

Contact Siveillance Technical Support at: [email protected]

--------- End Update A Part 1 of 1 ----------

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to run the devices in a protected IT environment, Siemens specifically recommends users configure the environment according to Siemens’ Operational Guidelines for Industrial Security and follow the recommendations in the product manuals.

Additional information on industrial security by Siemens can be found at:

<https://www.siemens.com/industrialsecurity&gt;

For more information on this vulnerability and associated software updates, please see Siemens security advisory SSA-457058 on their website:

<https://www.siemens.com/cert/advisories&gt;:

NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. High skill level is needed to exploit.

References

6.8 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:P/I:P/A:P

8.1 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

HIGH

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

0.056 Low

EPSS

Percentile

93.3%

Related for ICSA-18-128-02