2039 matches found
Obsolete versions of the `rustsec` crate do not support the new V3 advisory format
If you are seeing this message, you are running an obsolete version of cargo-audit which does not support the new V3 advisory format. These versions are end-of-life. This advisory is a notice that that it will soon be unable to parse the advisory database. Please upgrade cargo-audit to a newer...
B&R Automation SiteManager and GateManager
1. EXECUTIVE SUMMARY CVSS v3 7.7 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: B&R Industrial Automation GmbH Equipment: SiteManager and GateManager Vulnerabilities: Path Traversal, Uncontrolled Resource Consumption, Information Exposure, Improper Authentication, Information...
3S CoDeSys (Update A)
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit/public exploits are available Vendor: 3S-Smart Software Solutions Equipment: CoDeSys Vulnerabilities: Improper Access Control, Relative Path Traversal 2. UPDATE INFORMATION This updated advisory is a...
gkarchitects.com.au Improper Access Control vulnerability OBB-1347414
Following coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has:       a. verified the vulnerability and confirmed its existence;       b. notified the website operator about its existence...
Advantech WebAccess Node
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Advantech Equipment: WebAccess Node Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate their...
HMS Networks Ewon Flexy and Cosy
1. EXECUTIVE SUMMARY CVSS v3 2.3 ATTENTION: Low skill level to exploit Vendor: HMS Networks Equipment: Ewon Flexy and Cosy Vulnerability: Permissive Cross-domain Policy with Untrusted Domains 2. RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to retrieve...
CVE-2020-24074
The decode program in silk-v3-decoder Version:20160922 Build By kn007 does not strictly check data, resulting in a buffer overflow...
CVE-2020-24074
The decode program in silk-v3-decoder Version:20160922 Build By kn007 does not strictly check data, resulting in a buffer overflow...
Buffer overflow
The decode program in silk-v3-decoder Version:20160922 Build By kn007 does not strictly check data, resulting in a buffer overflow...
CVE-2020-24074
The decode program in silk-v3-decoder Version:20160922 Build By kn007 does not strictly check data, resulting in a buffer overflow...
CVE-2020-24074
CVE-2020-24074 concerns the silk-v3-decoder’s decode program. Connected sources consistently identify that silk-v3-decoder Version 20160922 (Build By kn007) does not strictly validate input data, which can lead to a buffer overflow. The affected component is the decode routine within silk-v3-deco...
Siemens SIMATIC HMI Products (Update A)
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC HMI Vulnerabilities: Improper Restriction of Excessive Authentication Attempts, Authentication Bypass by Primary Weakness 2. UPDATE INFORMATION This updated advisory is a...
CVE-2020-24030
ForLogic Qualiex v1 and v3 has weak token expiration. This allows remote unauthenticated privilege escalation and access to sensitive data via token reuse. NOTE: as of 2025-10-14, the Supplier's perspective is that this is "not exploitable in the current implementation. Tokens are properly expire...
Mitsubishi Electric Multiple Products (Update G)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Mitsubishi Electric Equipment : Multiple products Vulnerability : Predictable Exact Value from Previous Values 2. RISK EVALUATION Successful exploitation of this vulnerability could be used...
CVE-2020-23576
Laborator Neon dashboard v3 is affected by stored Cross Site Scripting XSS via the chat tab...
Cross site scripting
Laborator Neon dashboard v3 is affected by stored Cross Site Scripting XSS via the chat tab...
CVE-2020-23576
Laborator Neon dashboard v3 is affected by a stored XSS via the chat tab. The CVE-2020-23576 entry documents a stored cross-site scripting vulnerability in Laborator Neon dashboard v3, with CVSS v2 base score 3.5 (LOW) and CVSS v3.1 base score 5.4 (MEDIUM). The provided sources do not specify aff...
Advantech iView
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Advantech Equipment: iView Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to read/modify information, execute arbitrary code,...
covelljanipaschcpas.com Cross Site Scripting vulnerability OBB-1258183
Following coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has:       a. verified the vulnerability and confirmed its existence;       b. notified the website operator about its existence...
Siemens SICAM A8000 RTUs
1. EXECUTIVE SUMMARY CVSS v3 8.3 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SICAM A8000 Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could compromise the confidentiality, integrity, and availability of the web application...