Lucene search
+L

82 matches found

ATTACKERKB
ATTACKERKB
added 2022/07/12 11:00 a.m.6 views

CVE-2022-34765

A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication...

5.5CVSS5.9AI score0.00551EPSS
SaveExploits0References2Affected Software1
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:00 a.m.18 views

Schneider Electric Modicon Code Injection (CVE-2019-6816)

In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

9.1CVSS8.4AI score0.0145EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2021/03/10 12:00 a.m.11 views

Netgear NETGEAR JGS516PE 安全漏洞

The NETGEAR JGS516PE/GS116Ev2 is a 16-port Gigabit Smart Managed Plus switch. A firmware update vulnerability exists in the NETGEAR JGS516PE/GS116Ev2 version 2.6.0.43. The vulnerability stems from the TFTP server being active by default. An attacker could exploit this vulnerability to update the...

5.6AI score
SaveExploits0References2
Cvelist
Cvelist
added 2020/12/29 11:38 p.m.45 views

CVE-2020-35801

Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to...

8.3CVSS8AI score0.01685EPSS
SaveExploits0References2
Prion
Prion
added 2020/12/14 8:15 p.m.18 views

Race condition

Medtronic MyCareLink Smart 25000 all versions are vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited an attacker could remotely execute code on the MCL Smart Patient...

9.3CVSS8.5AI score0.0384EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/10/07 9:16 p.m.34 views

CVE-2020-15501

Smarter Coffee Maker before 2nd generation allows firmware replacement without authentication or authorization. User interaction is required to press a button. NOTE: This vulnerability only affects products that are no longer supported by the maintainer...

6.6AI score0.01097EPSS
SaveExploits1References1
CNVD
CNVD
added 2020/03/12 12:00 a.m.8 views

WAGO PFC200 Input Validation Error Vulnerability

The WAGO PFC 200 is a programmable logic controller PLC from the German company WAGO. An input validation error vulnerability exists in the cloud connectivity feature in WAGO PFC 200 using firmware versions 03.02.0214, 03.01.0713, and 03.00.3912. An attacker could exploit this vulnerability to ga...

9.1CVSS7AI score0.02672EPSS
SaveExploits1References1
Prion
Prion
added 2020/01/16 4:15 p.m.21 views

Design/Logic Flaw

A vulnerability has been identified in SINEMA Server All versions V14.0 SP2 Update 1. Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability...

9CVSS8.9AI score0.01208EPSS
SaveExploits0References2Affected Software1
HackRead
HackRead
added 2019/06/14 8:58 p.m.150 views

Vulnerable infusion pumps can be remotely accessed to change dosages

By Waqas Critical Bug in Medical Infusion Pumps lets Attacker Remotely install Unauthorized Firmware to Change Medication Dosages. Researchers at CyberMDX, a healthcare security firm, have identified two different vulnerabilities in Becton Dickinson Alaris Gateway Workstations AGW used by hospita...

1.3AI score
SaveExploits0
Prion
Prion
added 2018/03/02 1:29 a.m.19 views

Design/Logic Flaw

This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the...

8.3CVSS8.5AI score0.00782EPSS
SaveExploits0References1Affected Software1
OSV
OSV
added 2018/03/02 1:29 a.m.8 views

CVE-2018-1170

This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the...

8.8CVSS5.9AI score0.00782EPSS
SaveExploits0References1
CNVD
CNVD
added 2018/01/31 12:00 a.m.9 views

PHOENIX CONTACT mGuard Unauthorized Modification Vulnerability

Phoenix Contact mGuard is a security device from Phoenix Contact that protects systems from unauthorized access and installation. An unauthorized modification vulnerability exists in the PHOENIX CONTACT mGuard. The mGuard device relies on an internal verification of the integrity of the update...

7.8CVSS6.8AI score0.00283EPSS
SaveExploits0References1
NVD
NVD
added 2018/01/24 4:29 p.m.24 views

CVE-2018-4834

A vulnerability has been identified in Desigo PXC00-E.D V4.10 All versions V4.10.111, Desigo PXC00-E.D V5.00 All versions V5.0.171, Desigo PXC00-E.D V5.10 All versions V5.10.69, Desigo PXC00-E.D V6.00 All versions V6.0.204, Desigo PXC00/64/128-U V4.10 All versions V4.10.111 only with web module,...

10CVSS9.3AI score0.0333EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2018/01/24 4:00 p.m.30 views

CVE-2018-4834

A vulnerability has been identified in Desigo PXC00-E.D V4.10 All versions V4.10.111, Desigo PXC00-E.D V5.00 All versions V5.0.171, Desigo PXC00-E.D V5.10 All versions V5.10.69, Desigo PXC00-E.D V6.00 All versions V6.0.204, Desigo PXC00/64/128-U V4.10 All versions V4.10.111 only with web module,...

9.8CVSS9.2AI score0.0333EPSS
SaveExploits0References1
NVD
NVD
added 2017/11/22 8:29 a.m.20 views

CVE-2017-8862

The webupgrade function on the Cohu 3960HD does not verify the firmware upgrade files or process, allowing an attacker to upload a specially crafted postinstall.sh file that will be executed with "root" privileges...

10CVSS9.4AI score0.01483EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2017/10/11 12:00 a.m.27 views

CVE-2017-5701

Insecure platform configuration in system firmware for Intel NUC7i3BNK, NUC7i3BNH, NUC7i5BNK, NUC7i5BNH, NUC7i7BNH versions BN0049 and below allows an attacker with physical presence to run arbitrary code via unauthorized firmware modification during BIOS Recovery...

6.9AI score0.00328EPSS
SaveExploits0References2
NVD
NVD
added 2017/08/05 5:29 p.m.22 views

CVE-2017-9860

An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the invert...

10CVSS9.2AI score0.02244EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2017/08/05 5:00 p.m.32 views

CVE-2017-9860

An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the invert...

9.2AI score0.02244EPSS
SaveExploits0References3
NVD
NVD
added 2017/07/07 12:29 p.m.19 views

CVE-2017-7404

On the D-Link DIR-615 before v20.12PTb04, if a victim logged in to the Router's Web Interface visits a malicious site from another Browser tab, the malicious site then can send requests to the victim's Router without knowing the credentials CSRF. An attacker can host a page that sends a POST...

8.8CVSS8.6AI score0.00606EPSS
SaveExploits0References2
Cisco
Cisco
added 2016/02/12 8:50 p.m.50 views

Cisco Universal Small Cell Devices Unauthorized Firmware Retrieval Vulnerability

A vulnerability in Cisco Universal Small Cell devices could allow an unauthenticated, remote attacker to retrieve firmware from a Cisco-hosted binary server. The vulnerability is due to insufficient enforcement of the two-way certificate validation process by the Cisco-hosted binary server to...

5CVSS5.7AI score0.00916EPSS
SaveExploits0References1
Rows per page
Query Builder