Lucene search
+L

82 matches found

CVE
CVE
added 2024/05/14 10:02 a.m.56 views

CVE-2024-27944

Siemens RUGGEDCOM CROSSBOW is affected by CVE-2024-27944 (and related CVEs in the same advisory) for all versions prior to V5.5. The issue is external control of file name or path in the Firmware Upload Handler, enabling a privileged user to upload firmware to the root installation directory and ...

7.2CVSS7.5AI score0.01406EPSS
SaveExploits0References1Affected Software1
OSV
OSV
added 2023/04/28 1:15 p.m.12 views

CVE-2023-30024

The MagicJack device, a VoIP solution for internet phone calls, contains a hidden NAND flash memory partition allowing unauthorized read/write access. Attackers can exploit this by replacing the original software with a malicious version, leading to ransomware deployment on the host computer...

6.6CVSS6.7AI score0.00472EPSS
SaveExploits1References4
OSV
OSV
added 2023/04/17 10:15 p.m.8 views

CVE-2023-24500

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

6.5CVSS6.6AI score0.00177EPSS
SaveExploits0References1
OSV
OSV
added 2023/04/17 10:15 p.m.11 views

CVE-2023-24503

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

6.5CVSS6.6AI score0.00177EPSS
SaveExploits0References1
Prion
Prion
added 2023/04/17 10:15 p.m.17 views

Code injection

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

3.3CVSS6.4AI score0.00177EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2023/04/17 12:00 a.m.8 views

CVE-2023-24503 Electra Smart Kit for Split AC – Adjacent attacker may cause the unit to load unauthorized FW

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

7.5CVSS7.5AI score0.00177EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2023/04/17 12:00 a.m.8 views

CVE-2023-24500 Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

7.5CVSS6.8AI score0.00177EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2023/04/17 12:00 a.m.15 views

PT-2023-19650 · Electra · Electra Central Ac Unit

Name of the Vulnerable Software and Affected Versions: Electra Central AC unit affected versions not specified Description: The issue allows an adjacent attacker to cause the unit to load unauthorized firmware. Recommendations: At the moment, there is no information about a newer version that...

7.5CVSS6.3AI score0.00177EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2023/04/17 12:00 a.m.10 views

Electra Central AC unit 安全漏洞

The Electra Central AC unit is an Electra Central AC unit from Electra. A security vulnerability exists in the Electra Central AC unit. An attacker could exploit the vulnerability to cause unauthorized firmware to be loaded...

7.5CVSS6.5AI score0.00177EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2023/01/18 12:00 a.m.8 views

Dell iDRAC9 输入验证错误漏洞

The Dell iDRAC9 is a Dell offering that provides comprehensive, embedded management, and automation capabilities across the PowerEdge family of servers. A controller. A security vulnerability exists in Dell iDRAC9 version 6.00.02.00 and prior versions that originates from incorrect input validati...

4.9CVSS5.5AI score0.00513EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2022/09/13 2:54 p.m.26 views

CVE-2022-36385 Contec Health CMS8000

A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a...

6.8CVSS6.9AI score0.00374EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2022/07/21 12:00 a.m.44 views

Schneider Electric Modicon Exposure of Resource to Wrong Sphere (CVE-2022-34765)

A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user- controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication...

5.5CVSS6AI score0.00539EPSS
SaveExploits0References2
OSV
OSV
added 2022/07/13 9:15 p.m.7 views

CVE-2022-34765

A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication...

5.3CVSS5.8AI score0.00539EPSS
SaveExploits0References1
NVD
NVD
added 2022/07/13 9:15 p.m.27 views

CVE-2022-34762

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 an...

7.5CVSS0.00682EPSS
SaveExploits0References1
NVD
NVD
added 2022/07/13 9:15 p.m.28 views

CVE-2022-34763

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon...

7.5CVSS0.00273EPSS
SaveExploits0References1
OSV
OSV
added 2022/07/13 9:15 p.m.8 views

CVE-2022-34763

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon...

7.5CVSS5.8AI score0.00273EPSS
SaveExploits0References1
NVD
NVD
added 2022/07/13 9:15 p.m.19 views

CVE-2022-34765

A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication...

5.5CVSS0.00539EPSS
SaveExploits0References1
CVE
CVE
added 2022/07/13 9:11 p.m.74 views

CVE-2022-34765

CVE-2022-34765 is a CWE-73 vulnerability (External Control of File Name or Path) affecting Schneider Electric X80 advanced RTU Communication Module BMENOR2200H (V2.01 and later) and OPC UA Modicon Communication Module BMENUA0100 (V1.10 and prior). The issue arises when user-controlled data can in...

5.5CVSS5.2AI score0.00539EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/07/13 9:11 p.m.81 views

CVE-2022-34763

The CVE-2022-34763 entry describes a CWE-345 vulnerability (Insufficient Verification of Data Authenticity) that could allow loading of unauthorized firmware images due to improper verification of the firmware signature. Affected products are Schneider Electric X80 advanced RTU Communication Modu...

7.5CVSS7.4AI score0.00273EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.10 views

多款Schneider Electric产品安全漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

5.5CVSS5.8AI score0.00539EPSS
SaveExploits0References2
Rows per page
Query Builder