82 matches found
CVE-2024-27944
Siemens RUGGEDCOM CROSSBOW is affected by CVE-2024-27944 (and related CVEs in the same advisory) for all versions prior to V5.5. The issue is external control of file name or path in the Firmware Upload Handler, enabling a privileged user to upload firmware to the root installation directory and ...
CVE-2023-30024
The MagicJack device, a VoIP solution for internet phone calls, contains a hidden NAND flash memory partition allowing unauthorized read/write access. Attackers can exploit this by replacing the original software with a malicious version, leading to ransomware deployment on the host computer...
CVE-2023-24500
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...
CVE-2023-24503
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...
Code injection
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...
CVE-2023-24503 Electra Smart Kit for Split AC – Adjacent attacker may cause the unit to load unauthorized FW
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...
CVE-2023-24500 Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...
PT-2023-19650 · Electra · Electra Central Ac Unit
Name of the Vulnerable Software and Affected Versions: Electra Central AC unit affected versions not specified Description: The issue allows an adjacent attacker to cause the unit to load unauthorized firmware. Recommendations: At the moment, there is no information about a newer version that...
Electra Central AC unit 安全漏洞
The Electra Central AC unit is an Electra Central AC unit from Electra. A security vulnerability exists in the Electra Central AC unit. An attacker could exploit the vulnerability to cause unauthorized firmware to be loaded...
Dell iDRAC9 输入验证错误漏洞
The Dell iDRAC9 is a Dell offering that provides comprehensive, embedded management, and automation capabilities across the PowerEdge family of servers. A controller. A security vulnerability exists in Dell iDRAC9 version 6.00.02.00 and prior versions that originates from incorrect input validati...
CVE-2022-36385 Contec Health CMS8000
A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a...
Schneider Electric Modicon Exposure of Resource to Wrong Sphere (CVE-2022-34765)
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user- controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication...
CVE-2022-34765
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication...
CVE-2022-34762
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 an...
CVE-2022-34763
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon...
CVE-2022-34763
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon...
CVE-2022-34765
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication...
CVE-2022-34765
CVE-2022-34765 is a CWE-73 vulnerability (External Control of File Name or Path) affecting Schneider Electric X80 advanced RTU Communication Module BMENOR2200H (V2.01 and later) and OPC UA Modicon Communication Module BMENUA0100 (V1.10 and prior). The issue arises when user-controlled data can in...
CVE-2022-34763
The CVE-2022-34763 entry describes a CWE-345 vulnerability (Insufficient Verification of Data Authenticity) that could allow loading of unauthorized firmware images due to improper verification of the firmware signature. Affected products are Schneider Electric X80 advanced RTU Communication Modu...
多款Schneider Electric产品安全漏洞