1740 matches found
Schneider Electric Modicon M221 PLCs and SoMachine Basic Use of Hard-Coded Cryptographic Key (CVE-2017-7574)
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded- key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML...
Siemens SIPROTEC 5 Improper Input Validation (CVE-2021-37206)
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 All versions V8.80, SIPROTEC 5 relays with CPU variants CP100 All versions V8.80, SIPROTEC 5 relays with CPU variants CP300 All versions V8.80. Received webpackets are not properly processed. An unauthenticated remot...
Schneider Electric Modicon Controllers Trust Boundary Violation (CVE-2018-7846)
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller. This plugi...
Mitsubishi Electric MELSEC-Q Series and MELSEC-L Series CPU Modules Uncontrolled Resource Consumption (CVE-2019-13555)
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior,...
Siemens SIMATIC S7-1500 Open Redirect (CVE-2014-2248)
Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. This plugin only works with Tenable.ot. Please visi...
Schneider Electric Modicon Controllers Exposure of Sensitive Information to an Unauthorized Actor (CVE-2018-7844)
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus. This plugin only works with Tenable.ot...
Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6845)
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum all firmware versions, which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. This...
GE PACSystems RX3i Improper Input Validation (CVE-2019-13524)
GE PACSystems RX3i CPE100/115: All versions prior to R9.85,CPE302/305/310/330/400/410: All versions prior to R9.90,CRU/320 All versionsEnd of Life may allow an attacker sending specially manipulated packets to cause the module state to change to halt-mode, resulting in a denial-of-service...
Siemens Stack-Based Buffer Overflow in Wind River VxWorks (CVE-2019-12256)
Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets' IP options. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. C...
Johnson Controls Metasys Improper Restriction of XML External Entity Reference (CVE-2020-9044)
XXE vulnerability exists in the Metasys family of product Web Services which has the potential to facilitate DoS attacks or harvesting of ASCII server files. This affects Johnson Controls' Metasys Application and Data Server ADS, ADS-Lite versions 10.1 and prior; Metasys Extended Application and...
Schneider Electric Web Server on Modicon M340 Out-of-Bounds Read (CVE-2020-7562)
A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file ...
Siemens PROFINET Devices Uncontrolled Resource Consumption (CVE-2019-10936)
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP P...
SEL Controller Asset Information
It is possible to obtain attributes of the remote SEL Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc'; include"compat.inc...
Siemens SIMATIC S7-1500 Improper Input Validation (CVE-2016-2200)
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service STOP mode transition via crafted packets on TCP port 102. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300...
Schneider Electric PowerLogic PM55xx and PowerLogic PM8ECC Weak Password Recovery Mechanism For Forgotten Password (CVE-2021-22763)
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 see security notification for version infromation that could allow an attacker administrator level access to a device. This plug...
Beckhoff TwinCAT Installation Directory Incorrect Default Permissions (CVE-2020-12510)
The default installation path of the TwinCAT XAR 3.1 software in all versions is underneath C:\TwinCAT. If the directory does not exist it and further subdirectories are created with permissions which allow every local user to modify the content. The default installation registers TcSysUI.exe for...
Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2019-6851)
A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum all firmware versions, which could cause the disclosure of information from the controller when using TFTP protocol. This plugin only works with Tenable.ot...
Mitsubishi Electric MELSEC iQ-R Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2020-5653)
Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 Hi...
Omron Controller Asset Information
It is possible to obtain attributes of the remote Omron Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...
Siemens SIMATIC S7-1200 and S7-1500 CPU Families Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2020-15782)
A vulnerability has been identified in SIMATIC Drive Controller family All versions V2.9.2, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V21.9, SIMATIC S7-1200 CPU family incl...