Schneider Electric Modicon Cross-Site Request Forgery (CVE-2020-7534)
A CWE-352: Cross-Site Request Forgery CSRF vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in. Affected Products: Modicon M340 CPUs: BMXP34 All Versions, Modicon Quantum CPUs with...
Mitsubishi Electric MELSEC Series CPU Module Buffer Copy Without Checking Size of Input (CVE-2023-1424)
Buffer Copy without Checking Size of Input 'Classic Buffer Overflow' vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to cause a denial of service DoS condition or execute malicious code on a target product by sending special...
Schweitzer Engineering Laboratories RTAC Improper Input Validation (CVE-2023-31148)
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details. This plugin only works wi...
Siemens Industrial Products Deadlock (CVE-2022-43767)
A vulnerability has been identified in SIMATIC CP 1242-7 V2 All versions, SIMATIC CP 1243-1 All versions, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions, SIMATIC CP 1243-7 LTE EU All versions, SIMATIC CP 1243-7 LTE US All...
Siemens SICAM A8000 Web Server Module Improper Access Control (CVE-2021-46304)
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70C All versions, CP-8000 MASTER MODULE WITH I/O -40/+70C All versions, CP-8021 MASTER MODULE All versions, CP-8022 MASTER MODULE WITH GPRS All versions. The component allows to activate a web server module which provides...
FANUC Robot Controllers Out-of-Bounds Write (CVE-2021-32998)
The FANUC R-30iA and R-30iB series controllers are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. INIT START/restore from backup required. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for mo...
Siemens SCALANCE W1750D Improper Input Validation (CVE-2021-25155)
A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below...
Siemens SCALANCE W1750D Improper Neutralization of Input During Web Page Generation (CVE-2018-7064)
A reflected cross-site scripting XSS vulnerability is present in an unauthenticated Aruba Instant web interface. An attacker could use this vulnerability to trick an IAP administrator into clicking a link which could then take administrative actions on the Instant cluster, or expose the session...
Siemens SCALANCE W1750D Classic Buffer Overflow (CVE-2022-37889)
There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI Aruba Networks AP management protocol UDP port 8211. Successful exploitation of these vulnerabilities result...
Siemens SCALANCE W1750D Command Injection (CVE-2021-37730)
A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant IAP versions: Aruba Instant 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.20 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant...
Automated Logic Corporation ALC WebCTRL, Liebert SiteScan, Carrier i-VU Improper Restriction of XML External Entity Reference (CVE-2016-5795)
An XXE issue was discovered in Automated Logic Corporation ALC Liebert SiteScan Web Version 6.5 and prior, ALC WebCTRL Version 6.5 and prior, and Carrier i-Vu Version 6.5 and prior. An attacker could enter malicious input to WebCTRL, i-Vu, or SiteScan Web through a weakly configured XML parser...
Wago PFC200 iocheckd service 'I/O-Check' cache Memory Corruption (CVE-2019-5185)
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service I/O-Check functionality of WAGO PFC 200. An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1ea28 the extracted state value from the xml file is used as an...
WAGO PFC200 Series Improper Authentication (CVE-2018-5459)
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker...
Wago PFC100/PFC200 OS Command Injection (CVE-2020-12522)
The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 750-81xx/xxx-xxx, Series PFC 200 750-82xx/xxx-xxx, Series Wago Touch Panel 600 Standard Line 762-4xxx, Series Wago Touch Panel 600 Advanced Line...
Siemens SCALANCE X-200RNA Switch Devices Improper Encoding or Escaping of Output (CVE-2019-6109)
An issue was discovered in OpenSSH 7.9. Due to missing character encoding in the progress display, a malicious server or Man-in-The- Middle attacker can employ crafted object names to manipulate the client output, e.g., by using ANSI control codes to hide additional files being transferred. This...
Wago PFC200 iocheckd service 'I/O-Check' cache Command Injection (CVE-2019-5172)
An exploitable command injection vulnerability exists in the iocheckd service I/O-Check' function of the WAGO PFC 200 Firmware version 03.02.0214. An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e840 the extracted ntp value from the xml file is use...
Wago PFC100/200 Web-Based Management Authentication Timing Information Disclosure (CVE-2019-5135)
An exploitable timing discrepancy vulnerability exists in the authentication functionality of the Web-Based Management WBM web application on WAGO PFC100/200 controllers. The WBM application makes use of the PHP crypt function which can be exploited to disclose hashed user credentials. This affec...
WAGO I/O-CHECK Buffer Access with Incorrect Length Value (CVE-2019-5075)
An exploitable stack buffer overflow vulnerability exists in the command line utility getcouplerdetails of WAGO PFC200 Firmware versions 03.01.0713 and 03.00.3912, and WAGO PFC100 Firmware version 03.00.3912. A specially crafted set of packets sent to the iocheckd service I/O-Check can cause a...
Wago PFC200 iocheckd service 'I/O-Check' cache Command Injection (CVE-2019-5174)
An exploitable command injection vulnerability exists in the iocheckd service I/O-Check' function of the WAGO PFC 200 version 03.02.0214. A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted...
Wago PFC200 iocheckd service 'I/O-Check' cache Code Execution (CVE-2019-5178)
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service I/O-Check' functionality of WAGO PFC 200 Firmware version 03.02.0214. An attacker can send a specially crafted packet to trigger the parsing of this cache file. The destination buffer sp+0x440 is...