661 matches found
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53103)
hvsock: Initializing vsk-trans to NULL to prevent a dangling pointer When hvs is released, there is a possibility that vsk-trans may not be initialized to NULL, which could lead to a dangling pointer. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56720)
bpf, sockmap: Several fixes to bpfmsgpopdata, 1. In skmsgshiftleft, it should putpage 2. if len == 0, returning early is better 3. pop the entire skmsg last == msg-sg.size should be supported 4. Fix for the value of variable a 5. In skmsgshiftleft, after shifting, it has already pointed to the ne...
Siemens SIPROTEC 5 Use of Http Request with Sensitive Query String (CVE-2025-40742)
The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access. This plugin only works with Tenable.ot...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56681)
crypto: bcm - add error check in the ahashhmacinit function The ahashinit functions may return fails. The ahashhmacinit should not return ok when ahashinit returns error. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56698)
usb: dwc3: gadget: looping of queued SG entries The dwc3request-numqueuedsgs is decremented on completion. If a partially completed request is handled, then the dwc3request-numqueuedsgs no longer reflects the total number of numqueuedsgs it would be cleared. This plugin only works with Tenable.ot...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50024)
net: unsafe loop on the list. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504469; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49963)
mailbox: bcm2835: timeout during suspend mode. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504800; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-45003)
vfs: Some filesystemseg. ext4 with eainode feature, ubifs with xattr may do inode lookup in the inode evicting callback function, if the inode lookup is operated under the inode lru traversing context, deadlock problems may happen. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56574)
media: ts2020: null-ptr-deref in ts2020probe. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504729; scriptversion"1.3";...
Siemens RUGGEDCOM ROX II Client-Side Enforcement of Server-Side Security (CVE-2025-32469)
The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM Devices Inadequate Encryption Strength (CVE-2021-37209)
The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in- the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. This plugin only works with...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50013)
exfat: memory leak in exfatloadbitmap If the first directory entry in the root directory is not a bitmap directory entry, 'bh' will not be released and reassigned, which will cause a memory leak. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50184)
virtiopmem: Check device status before requesting flush. If a pmem device is in a bad status, the driver side could wait for host ack forever in virtiopmemflush, causing the system to hang. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50237)
wifi: mac80211: do not pass a stopped vif to the driver in .gettxpower Avoid potentially crashing in the driver because of uninitialized private data. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...
Siemens SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-47748)
vhostvdpa: assign irq bypass producer token correctly. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504731; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56595)
jfs: add a check to prevent array-index-out-of-bounds in dbAdjTree. When the value of lp is 0 at the beginning of the for loop, it will become negative in the next assignment and we should bail out. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot f...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46755)
wifi: mwifiex: Do not return unused priv in mwifiexgetprivbyid. mwifiexgetprivbyid returns the priv pointer corresponding to the bssnum and bsstype, but without checking if the priv is actually currently in use. Unused priv pointers do not have a wiphy attached to them which can lead to NULL...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49895)
drm/amd/display: vulnerability caused by adding a check to ensure the index 'i' is within bounds before accessing transfer function points in cmhelpertranslatecurvetodegammahwformat, preventing buffer overflow errors. This plugin only works with Tenable.ot. Please visit...
Resource Allocation in Siemens RUGGEDCOM Allocation of Resources Without Limits or Throttling (CVE-2023-39269)
The web server of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause total loss of availability of the web server, which might recover after the attack is over. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Allocation of Resources Without Limits or Throttling (CVE-2024-41009)
bpf: Fix overrunning reservations in ringbuf. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504616; scriptversion"1.3";...