Lucene search
+L

Siemens RUGGEDCOM ROX II Client-Side Enforcement of Server-Side Security (CVE-2025-32469)

🗓️ 18 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 6 Views

Ruggedcom Rox II ping tool allows command injection from poor input sanitation; authenticated attacker can run as root.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504451);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/04/01");

  script_cve_id("CVE-2025-32469");
  script_xref(name:"ICSA", value:"25-135-17");

  script_name(english:"Siemens RUGGEDCOM ROX II Client-Side Enforcement of Server-Side Security (CVE-2025-32469)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"The 'ping' tool in the web interface of affected devices is vulnerable
to command injection due to missing server side input sanitation. This
could allow an authenticated remote attacker to execute arbitrary code
with root privileges.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-301229.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988071/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-17");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V2.16.5 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-301229 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-32469");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(602);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/05/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/05/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
        {"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

01 Apr 2026 00:00Current
6.1Medium risk
Vulners AI Score6.1
CVSS 49.4
CVSS 3.19.9
EPSS0.0121
SSVC
6