Siemens RUGGEDCOM ROX II Client-Side Enforcement of Server-Side Security (CVE-2025-32469)
| Reporter | Title | Published | Views | Family All 10 |
|---|---|---|---|---|
| The vulnerability of the ping tool in the web interface of the microprogramming software for routing and switching platform RUGGEDCOM ROX series, MX (MX5000, MX5000RE) and RX (RX1400, RX1501, RX1510, RX1511, RX1512, RX1524, RX1536, and RX5000), allows a hacker to execute arbitrary code. | 9 Jun 202500:00 | – | bdu_fstec | |
| CVE-2025-32469 | 13 May 202510:30 | – | circl | |
| siemens多款产品 安全漏洞 | 13 May 202500:00 | – | cnnvd | |
| CVE-2025-32469 | 13 May 202509:38 | – | cve | |
| CVE-2025-32469 | 13 May 202509:38 | – | cvelist | |
| EUVD-2025-14381 | 3 Oct 202520:07 | – | euvd | |
| CVE-2025-32469 | 13 May 202510:15 | – | nvd | |
| PT-2025-20860 · Siemens · Ruggedcom Rox Mx5000 +8 | 13 May 202500:00 | – | ptsecurity | |
| CVE-2025-32469 | 15 May 202510:11 | – | redhatcve | |
| CVE-2025-32469 | 13 May 202509:38 | – | vulnrichment |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(504451);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/04/01");
script_cve_id("CVE-2025-32469");
script_xref(name:"ICSA", value:"25-135-17");
script_name(english:"Siemens RUGGEDCOM ROX II Client-Side Enforcement of Server-Side Security (CVE-2025-32469)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"The 'ping' tool in the web interface of affected devices is vulnerable
to command injection due to missing server side input sanitation. This
could allow an authenticated remote attacker to execute arbitrary code
with root privileges.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-301229.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988071/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-17");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Update to V2.16.5 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-301229 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-32469");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(602);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/05/13");
script_set_attribute(attribute:"patch_publication_date", value:"2025/05/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
{"versionEndExcluding" : "2.16.5", "family" : "RuggedCom"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
01 Apr 2026 00:00Current
6.1Medium risk
Vulners AI Score6.1
CVSS 49.4
CVSS 3.19.9
EPSS0.0121
SSVC