Siemens SIMATIC and SIPLUS products Uncontrolled Resource Consumption (CVE-2025-40944)
Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request COTP DR TPDU on TCP port 102, the devices enter an improper session state. This could allow an attacker to cause the device to become unresponsive, leading to a...
EUVD-2020-17932
Malware in sbrugna...
EUVD-2013-0711
Malware in sbrugna...
EUVD-2016-3284
Malware in sbrugna...
EUVD-2016-3285
Malware in sbrugna...
CVE-2020-25242
A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Standard incl. SIPLUS variants All versions. Specially crafted packets sent to TCP port 102 could cause a...
CVE-2018-16556
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 All versions, SIMATIC S7-400 CPU 412-2 DP V7 All versions, SIMATIC S7-400 CPU 414-2 DP V7 All versions, SIMATIC S7-400 CPU 414-3 DP V7 All versions, SIMATIC S7-400 CPU 414-3 PN/DP V7 All versions V7.0.3, SIMATIC S7-400 CPU 414F...
Siemens SIMATIC NET CP343-1 Uncontrolled Resource Consumption (CVE-2020-25242)
A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Standard incl. SIPLUS variants All versions. Specially crafted packets sent to TCP port 102 could cause a...
Denial of service
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device...
CVE-2021-40368
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 All versions, SIMATIC S7-400 CPU 412-2 DP V7 All versions, SIMATIC S7-400 CPU 412-2 PN/DP V7 All versions V7.0.3, SIMATIC S7-400 CPU 414-2 DP V7 All versions, SIMATIC S7-400 CPU 414-3 DP V7 All versions, SIMATIC S7-400 CPU 414-...
CVE-2021-37205
A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial-of-service condition in a PLC...
Siemens SIMATIC S7-1200 CPU Family Denial of Service (CVE-2013-0700)
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service defect-mode transition and control outage via crafted packets to TCP port 102 aka the ISO-TSAP port. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for mo...
Siemens SIMATIC S7-1500 Protection Mechanism Failure (CVE-2016-2201)
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network...
CVE-2020-25242
A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Standard incl. SIPLUS variants All versions. Specially crafted packets sent to TCP port 102 could cause a...
Design/Logic Flaw
A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC NET CP 343-1 Standard incl. SIPLUS variants All versions. Specially crafted packets sent to TCP port 102 could cause a...
CVE-2020-25242
CVE-2020-25242 affects Siemens SIMATIC NET CP 343-1 devices (Advanced/Lean/Standard, including SIPLUS variants) across all versions. The vulnerability is an Uncontrolled Resource Consumption issue triggered by specially crafted packets sent to TCP port 102, allowing a remote DoS that may require ...
Siemens SIMATIC NET CP343-1
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC CP343-1 devices Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service condition...
Siemens SIMATIC S7-1500 CPU - Remote Denial of Service
Siemens SIMATIC S7-1500 CPU - Remote Denial of Service Exploit Title: Siemens SIMATIC S7-1500 CPU - Remote Denial of Service Google Dork: inurl:/Portal/Portal.mwsl Date: 2018-05-22 Exploit Author: t4rkd3vilz, Jameel Nabbo Vendor Homepage: https://www.siemens.com/ Version: SIMATIC S7-1500 CPU all...
Siemens SIMATIC S7-1500 CPU - Remote Denial of Service
Exploit Title: Siemens SIMATIC S7-1500 CPU - Remote Denial of Service Google Dork: inurl:/Portal/Portal.mwsl Date: 2018-05-22 Exploit Author: t4rkd3vilz, Jameel Nabbo Vendor Homepage: https://www.siemens.com/ Version: SIMATIC S7-1500 CPU all versions before V1.6 Tested on: Kali Linux CVE:...