| Reporter | Title | Published | Views | Family All 11 |
|---|---|---|---|---|
| CVE-2025-40944 | 13 Jan 202611:01 | – | circl | |
| Siemens多款产品 资源管理错误漏洞 | 13 Jan 202600:00 | – | cnnvd | |
| CVE-2025-40944 | 13 Jan 202609:44 | – | cve | |
| CVE-2025-40944 | 13 Jan 202609:44 | – | cvelist | |
| EUVD-2026-2359 | 13 Jan 202609:44 | – | euvd | |
| Siemens SIMATIC and SIPLUS products | 13 Jan 202600:00 | – | ics | |
| Vulnerabilities fixed in Siemens products | 13 Jan 202612:05 | – | ncsc | |
| CVE-2025-40944 | 13 Jan 202610:15 | – | nvd | |
| PT-2026-2354 | 13 Jan 202600:00 | – | ptsecurity | |
| CVE-2025-40944 | 14 Jan 202610:25 | – | redhatcve |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505099);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/14");
script_cve_id("CVE-2025-40944");
script_xref(name:"ICSA", value:"26-015-04");
script_name(english:"Siemens SIMATIC and SIPLUS products Uncontrolled Resource Consumption (CVE-2025-40944)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"Affected devices do not properly handle S7 protocol session disconnect
requests. When receiving a valid S7 protocol Disconnect Request (COTP
DR TPDU) on TCP port 102, the devices enter an improper session state.
This could allow an attacker to cause the device to become
unresponsive, leading to a denial-of-service condition that requires a
power cycle to restore normal operation.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-674753.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109760973/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109769419/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109816000/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109987451/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-015-04");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-40944");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(400);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/01/13");
script_set_attribute(attribute:"patch_publication_date", value:"2026/01/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/02/10");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200al_im_157-1_pn_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:4.2.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200sp_im_155-6_mf_hf_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200sp_im_155-6_pn%2f2_hf_firmware:4.2.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200sp_im_155-6_pn%2f3_hf_firmware:4.2.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:1.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200sp_im_155-6_pn_r1_firmware:6.0.1");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200mp_im_155-5_pn_hf_firmware:4.2.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200mp_im_155-5_pn_hf_t1_rail_firmware:4.2.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200sp_im_155-6_pn_hf_firmware:4.2.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200sp_im_155-6_pn_hf_t1_rail_firmware:4.2.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_et_200sp_im_155-6_pn_hf_tx_rail_firmware:4.2.0");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_et_200al_im_157-1_pn_firmware" :
{"family" : "ET200", "orderNumbers" : ['6ES7157-1AB00-0AB0']},
"cpe:/o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:4.2.0" :
{"versionStartIncluding" : "4.2.0", "family" : "ET200", "orderNumbers" : ['6ES7155-5AA00-0AC0']},
"cpe:/o:siemens:simatic_et_200sp_im_155-6_mf_hf_firmware" :
{"family" : "ET200SP", "orderNumbers" : ['6ES7155-6MU00-0CN0']},
"cpe:/o:siemens:simatic_et_200sp_im_155-6_pn%2f2_hf_firmware:4.2.0" :
{"versionStartIncluding" : "4.2.0", "family" : "ET200SP", "orderNumbers" : ['6ES7155-6AU01-0CN0']},
"cpe:/o:siemens:siplus_et_200mp_im_155-5_pn_hf_firmware:4.2.0" :
{"versionStartIncluding" : "4.2.0", "family" : "ET200", "orderNumbers" : ['6AG1155-5AA00-7AC0', '6AG1155-5AA00-2AC0']},
"cpe:/o:siemens:siplus_et_200mp_im_155-5_pn_hf_t1_rail_firmware:4.2.0" :
{"versionStartIncluding" : "4.2.0", "family" : "ET200", "orderNumbers" : ['6AG2155-5AA00-1AC0']},
"cpe:/o:siemens:siplus_et_200sp_im_155-6_pn_hf_firmware:4.2.0" :
{"versionStartIncluding" : "4.2.0", "family" : "ET200", "orderNumbers" : ['6AG1155-6AU01-2CN0', '6AG1155-6AU01-7CN0']},
"cpe:/o:siemens:siplus_et_200sp_im_155-6_pn_hf_t1_rail_firmware:4.2.0" :
{"versionStartIncluding" : "4.2.0", "family" : "ET200", "orderNumbers" : ['6AG2155-6AU01-1CN0']},
"cpe:/o:siemens:siplus_et_200sp_im_155-6_pn_hf_tx_rail_firmware:4.2.0" :
{"versionStartIncluding" : "4.2.0", "family" : "ET200", "orderNumbers" : ['6AG2155-6AU01-4CN0']},
"cpe:/o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:1.3" :
{"versionEndExcluding" : "1.3", "family" : "ET200SP"},
"cpe:/o:siemens:simatic_et_200sp_im_155-6_pn%2f3_hf_firmware:4.2.2" :
{"versionEndExcluding" : "4.2.2", "family" : "ET200SP", "orderNumbers" : ['6ES7155-6AU30-0CN0']},
"cpe:/o:siemens:simatic_et_200sp_im_155-6_pn_r1_firmware:6.0.1" :
{"versionEndExcluding" : "6.0.1", "family" : "ET200SP", "orderNumbers" : ['6ES7155-6AU00-0HM0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation