Lucene search
+L

13 matches found

Tenable Nessus
Tenable Nessus
added 2024/02/20 12:0 a.m.32 views

Siemens SIMATIC CP products Uncontrolled Resource Consumption (CVE-2023-37195)

A vulnerability has been identified in SIMATIC CP 1604 All versions, SIMATIC CP 1616 All versions, SIMATIC CP 1623 All versions, SIMATIC CP 1626 All versions, SIMATIC CP 1628 All versions. Affected devices insufficiently control continuous mapping of direct memory access DMA requests. This could...

4.4CVSS5.8AI score0.00163EPSS
Exploits0References3
CNNVD
CNNVD
added 2023/12/12 12:0 a.m.6 views

Siemens SIMATIC CP 1242-7 安全漏洞

SIMATIC CP 1242 and CP 1243 correlation processors connect SIMATIC S7-1200 controllers to a wide area network WAN. They provide integrated security features such as firewalls, virtual private networks VPNs, and support for other data encryption protocols.SIMATIC CP 1543-1 communication processors...

8.7CVSS6.6AI score0.00956EPSS
Exploits0References5
CNNVD
CNNVD
added 2023/10/10 12:0 a.m.7 views

Siemens SIMATIC 多款产品访问控制错误漏洞

The SIMATIC CP 1623, CP 1626 and CP 1628 are PCI express cards for connection to industrial Ethernet. the SIMATIC CP 1604 and CP 1616 are PCI/PCI-104 cards for the connection of field devices to PROFINET industrial Ethernet. The Siemens SIMATIC CP devices suffer from an Improper Access Control...

6.7CVSS7.7AI score0.00184EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.23 views

Siemens SIMATIC CP 1543-1 Improper Privilege Management (CVE-2016-8561)

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Users with elevated privileges to TIA-Portal and project data on the engineering station could possibly get privileged access on affected devices. This plugin only works with...

6.6CVSS6.4AI score0.01585EPSS
Exploits0References6
Tenable Nessus
Tenable Nessus
added 2023/05/02 12:0 a.m.37 views

Siemens SIMATIC CP Use After Free (CVE-2020-9273)

In ProFTPD 1.3.7, it is possible to corrupt the memory pool by interrupting the data transfer channel. This triggers a use-after-free in allocpool in pool.c, and possible remote code execution. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for mo...

9CVSS6.7AI score0.12045EPSS
Exploits1References14
Tenable Nessus
Tenable Nessus
added 2022/03/15 12:0 a.m.48 views

Siemens SIMATIC CP 1543-1 Improper Input Validation (CVE-2016-8562)

A vulnerability has been identified in SIMATIC CP 1543-1 All versions V2.0.28, SIPLUS NET CP 1543-1 All versions V2.0.28. Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these...

7.5CVSS6.4AI score0.03624EPSS
Exploits0References4
The Hacker News
The Hacker News
added 2022/03/05 7:32 a.m.120 views

CISA Adds Another 95 Flaws to its Actively Exploited Vulnerabilities Catalog

The U.S. Cybersecurity and Infrastructure Security Agency CISA this week added 95 more security flaws to its Known Exploited Vulnerabilities Catalog, taking the total number of actively exploited vulnerabilities to 478. "These types of vulnerabilities are a frequent attack vector for malicious...

10CVSS1.9AI score0.72458EPSS
Exploits7
VulnCheck KEV
VulnCheck KEV
added 2022/03/03 12:0 a.m.6 views

VulnCheck KEV: CVE-2016-8562

An improper privilege management vulnerability exists within the Siemens SIMATIC Communication Processor CP that allows a privileged attacker to remotely cause a denial of service...

7.5CVSS6.6AI score0.03624EPSS
Exploits0References1
Tenable Nessus
Tenable Nessus
added 2019/05/21 12:0 a.m.29 views

Siemens SIMATIC CP 343-1, CP 443-1 Authentication Bypass Vulnerability

Binary data 137.prm...

9.7CVSS7.3AI score0.02149EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:0 a.m.6 views

Siemens SIMATIC CP 1543-1 < 2.0.28 Privilege Elevation

Binary data 720091.prm...

6.6CVSS7.3AI score0.01585EPSS
Exploits0References2
OpenVAS
OpenVAS
added 2018/02/01 12:0 a.m.100 views

Siemens SIMATIC CP Device Detection (HTTP)

This script performs HTTP based detection of Siemens SIMATIC CP devices. SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only if description...

7.1AI score
Exploits0
OpenVAS
OpenVAS
added 2018/02/01 12:0 a.m.20 views

Siemens SIMATIC CP Device Detection Consolidation

Consolidation of Siemens SIMATIC CP device detections. Copyright C 2018 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free software; you ca...

7.1AI score
Exploits0References1
0day.today
0day.today
added 2017/01/12 12:0 a.m.52 views

Siemens SIMATIC CP 343-1 Advanced IKEv1 Cipher Suite Configuration Vulnerability

The SIMATIC CP 343-1 Advanced product allows configuration of the IKEv1 cipher suite configuration, which specifies the IKE and Encapsulating Security Payload ESP supported algorithms, with one cipher for each setting. It is evaluated that the configuration is not consistent with the supported...

6.9AI score
Exploits0
Rows per page
Query Builder