Lucene search
+L

4537 matches found

BDU FSTEC
BDU FSTEC
added 2024/12/11 12:00 a.m.13 views

The vulnerability of the microprogramming software for Schneider Electric’s programmable logic controllers (PLC) models M241, M251, M258, and LMC058 is related to errors in processing input data. This vulnerability allows attackers to trigger maintenance failures and compromise the confidentiality, integrity, and accessibility of protected information.

The vulnerability of the microprogrammed software of Schneider Electric’s programmable logic controllers PLC models M241, M251, M258, and LMC058 is related to errors in processing input data. Exploiting this vulnerability can allow an attacker to trigger maintenance failures and compromise the...

10CVSS5.5AI score0.00637EPSS
SaveExploits0References2
ICS
ICS
added 2024/12/10 5:00 a.m.13 views

Schneider Electric Modicon

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

9.8CVSS6.5AI score0.00637EPSS
SaveExploits0References11
BDU FSTEC
BDU FSTEC
added 2024/12/09 12:00 a.m.18 views

The vulnerability of the Modbus protocol implementation in Schneider Electric Modicon M340 CPU BMXP34 programmable logic controllers allows a perpetrator to carry out a “man-in-the-middle” attack.

The vulnerability of the Modbus protocol implementation in Schneider Electric Modicon M340 CPU BMXP34 programmable logic controllers is related to insufficient verification of input data. Exploiting this vulnerability can allow an attacker to carry out a “man-in-the-middle” attack remotely...

6.5CVSS5.4AI score0.00499EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2024/12/09 12:00 a.m.16 views

The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers (PLCs), such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, allows a attacker to execute a “man-in-the-middle” attack.

The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers PLCs such as Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the execution of operations outside the buffer in memory. Exploiting th...

8.1CVSS6.1AI score0.00532EPSS
SaveExploits0References2Affected Software1
Tenable Nessus
Tenable Nessus
added 2024/12/04 12:00 a.m.12 views

Schneider Electric IONXXXX Series Power Meter Improper Access Control (CVE-2016-5815)

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make...

9.8CVSS8.5AI score0.02452EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2024/12/04 12:00 a.m.13 views

Schneider Electric IONXXXX Series Power Meter Cross-site Request Forgery (CVE-2016-5809)

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability ca...

8.8CVSS7.9AI score0.02045EPSS
SaveExploits4References4
Tenable Nessus
Tenable Nessus
added 2024/11/28 12:00 a.m.10 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Input Validation (CVE-2024-8936)

An Input Validation vulnerability exists that could lead to loss of confidentiality of controller memory after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call used to tamper with memory. This plugin only works with Tenable.ot. Please visit...

8.3CVSS5.5AI score0.00499EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2024/11/28 12:00 a.m.13 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2024-8933)

A vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of confidentiality and integrity of controllers. To be successful, the attacker needs to inject themselves inside the logical network while a valid user uploads or downloads a project...

7.7CVSS5.5AI score0.00501EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2024/11/28 12:00 a.m.21 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2024-8937)

Arbitrary code execution can potentially be achieved after a successful Man-In-The Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in the authentication process. This plugin only works with Tenable.ot. Please visit...

8.3CVSS6.1AI score0.00586EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2024/11/28 12:00 a.m.11 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2024-8938)

Arbitrary code execution can potentially be achieved after a successful Man-In-The Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation. This plugin only works with Tenable.ot. Please visit...

9.2CVSS6AI score0.00532EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2024/11/28 12:00 a.m.14 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Authentication Bypass By Spoofing (CVE-2024-8935)

A vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is...

7.7CVSS5.5AI score0.00501EPSS
SaveExploits0References3
CISA
CISA
added 2024/11/26 12:00 p.m.24 views

CISA Releases Six Industrial Control Systems Advisories

CISA released six Industrial Control Systems ICS advisories on November 26, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-331-01 Schneider Electric PowerLogic PM55xx and PowerLogic PM8ECC ICSA-24-331-02...

6.7AI score
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2024/11/19 12:00 a.m.10 views

PT-2024-10220 · Schneider Electric · Bmenor2200H +4

Name of the Vulnerable Software and Affected Versions: No specific software or versions are mentioned in the provided descriptions. Description: A vulnerability exists that could cause Denial-of-Service of the product when an unauthenticated user sends a crafted HTTPS packet to the webserver. Thi...

8.7CVSS7.3AI score0.00628EPSS
SaveExploits0References19
Tenable Nessus
Tenable Nessus
added 2024/11/19 12:00 a.m.20 views

Schneider Electric PowerLogic PM5300 Series Uncontrolled Resource Consumption (CVE-2024-9409)

CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network. This plugin only works with Tenable.ot. Please visit...

8.7CVSS5.5AI score0.00816EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2024/11/15 12:00 a.m.14 views

The vulnerability of Schneider Electric Data Center Expert, a monitoring software for equipment information, arises from improper verification of the cryptographic signature. This allows an attacker to execute arbitrary bash scripts as the root user.

The vulnerability of the Schneider Electric Data Center Expert monitoring software relates to improper verification of the cryptographic signature. Exploiting this vulnerability may allow a malicious actor, operating remotely, to execute arbitrary bash commands under the identity of the root user...

9CVSS7.5AI score0.00459EPSS
SaveExploits0References6Affected Software1
NCSC
NCSC
added 2024/11/14 12:46 p.m.19 views

Vulnerability fixed in Schneider Electric Ecostruxture

Schneider Electric has fixed a vulnerability in the Ecostruxture Gateway. A malicious party could exploit the vulnerability to take over the gateway to gain access to the Ecostruxture landscape in use. For successful abuse, the malicious party must have access to the production environment. It is...

10CVSS7AI score0.00647EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/11/13 12:00 a.m.11 views

Schneider Electric EcoStruxure IT Gateway 安全漏洞

Schneider Electric EcoStruxure IT Gateway is a suite of cloud-based data center management-as-a-service DMaaS offerings from Schneider Electric, a French company. A security vulnerability exists in Schneider Electric EcoStruxure IT Gateway that stems from a lack of authorization vulnerability tha...

10CVSS6.4AI score0.00647EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/11/13 12:00 a.m.13 views

Schneider Electric Modicon M340 安全漏洞

The Schneider Electric Modicon M340 is a medium-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric, France. A security vulnerability exists in the Schneider Electric Modicon M340 that arises from improper implementation of message integrity...

7.5CVSS6.4AI score0.00292EPSS
SaveExploits0References2
ICS
ICS
added 2024/11/12 5:00 a.m.21 views

Schneider Electric Modicon M340, MC80, and Momentum Unity M1E (Update B)

GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...

6.5AI score
SaveExploits0References11
Positive Technologies
Positive Technologies
added 2024/11/12 12:00 a.m.14 views

PT-2024-9215 · Schneider Electric · Modicon Mc80 Bmkc80 +2

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU affected versions not specified Description: The issue is related to the lack of message integrity checks during transmission ove...

7.5CVSS7.3AI score0.00292EPSS
SaveExploits0References6