Lucene search
K

Schneider Electric IONXXXX Series Power Meter Improper Access Control (CVE-2016-5815)

🗓️ 04 Dec 2024 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 8 Views

Schneider Electric IONXXXX Series Power Meter lacks authentication, allowing unauthorized access.

Related
Refs
Code
ReporterTitlePublishedViews
Family
Tenable Nessus
Schneider Electric IONXXXX Power Meters 1.1 <= 4.1 Authentication Bypass
8 May 201900:00
nessus
CNVD
Schneider Electric ION Security Bypass Vulnerability
6 Nov 201600:00
cnvd
CVE
CVE-2016-5815
13 Feb 201721:00
cve
Cvelist
CVE-2016-5815
13 Feb 201721:00
cvelist
EUVD
EUVD-2016-6750
7 Oct 202500:30
euvd
ICS
Schneider Electric IONXXXX Series Power Meter Vulnerabilities
3 Nov 201612:00
ics
NVD
CVE-2016-5815
13 Feb 201721:59
nvd
Prion
Design/Logic Flaw
13 Feb 201721:59
prion
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(502761);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/12/05");

  script_cve_id("CVE-2016-5815");
  script_xref(name:"ICSA", value:"16-308-03");

  script_name(english:"Schneider Electric IONXXXX Series Power Meter Improper Access Control (CVE-2016-5815)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"An issue was discovered on Schneider Electric IONXXXX series power
meters ION73XX series, ION75XX series, ION76XX series, ION8650 series,
ION8800 series, and PM5XXX series. No authentication is configured by
default. An unauthorized user can access the device management portal
and make configuration changes.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/94091");
  script_set_attribute(attribute:"see_also", value:"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2016-5815");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(284);

  script_set_attribute(attribute:"vuln_publication_date", value:"2017/02/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2017/02/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2024/12/04");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion5000:-");
  script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion7300:-");
  script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion7500:-");
  script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion7600:-");
  script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion8650:-");
  script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion8800:-");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/h:schneider-electric:ion5000:-" :
        {"family" : "ION"},
    "cpe:/h:schneider-electric:ion7300:-" :
        {"family" : "ION"},
    "cpe:/h:schneider-electric:ion7500:-" :
        {"family" : "ION"},
    "cpe:/h:schneider-electric:ion7600:-" :
        {"family" : "ION"},
    "cpe:/h:schneider-electric:ion8650:-" :
        {"family" : "ION"},
    "cpe:/h:schneider-electric:ion8800:-" :
        {"family" : "ION"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

05 Dec 2024 00:00Current
8.5High risk
Vulners AI Score8.5
CVSS 27.5
CVSS 39.8
EPSS0.02452
8