| Reporter | Title | Published | Views | Family All 8 |
|---|---|---|---|---|
| Schneider Electric IONXXXX Power Meters 1.1 <= 4.1 Authentication Bypass | 8 May 201900:00 | – | nessus | |
| Schneider Electric ION Security Bypass Vulnerability | 6 Nov 201600:00 | – | cnvd | |
| CVE-2016-5815 | 13 Feb 201721:00 | – | cve | |
| CVE-2016-5815 | 13 Feb 201721:00 | – | cvelist | |
| EUVD-2016-6750 | 7 Oct 202500:30 | – | euvd | |
| Schneider Electric IONXXXX Series Power Meter Vulnerabilities | 3 Nov 201612:00 | – | ics | |
| CVE-2016-5815 | 13 Feb 201721:59 | – | nvd | |
| Design/Logic Flaw | 13 Feb 201721:59 | – | prion |
| Source | Link |
|---|---|
| securityfocus | www.securityfocus.com/bid/94091 |
| ics-cert | www.ics-cert.us-cert.gov/advisories/ICSA-16-308-03 |
| cve | www.cve.mitre.org/cgi-bin/cvename.cgi |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(502761);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/12/05");
script_cve_id("CVE-2016-5815");
script_xref(name:"ICSA", value:"16-308-03");
script_name(english:"Schneider Electric IONXXXX Series Power Meter Improper Access Control (CVE-2016-5815)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"An issue was discovered on Schneider Electric IONXXXX series power
meters ION73XX series, ION75XX series, ION76XX series, ION8650 series,
ION8800 series, and PM5XXX series. No authentication is configured by
default. An unauthorized user can access the device management portal
and make configuration changes.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/94091");
script_set_attribute(attribute:"see_also", value:"https://ics-cert.us-cert.gov/advisories/ICSA-16-308-03");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2016-5815");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(284);
script_set_attribute(attribute:"vuln_publication_date", value:"2017/02/13");
script_set_attribute(attribute:"patch_publication_date", value:"2017/02/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2024/12/04");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion5000:-");
script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion7300:-");
script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion7500:-");
script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion7600:-");
script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion8650:-");
script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:ion8800:-");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Schneider");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Schneider');
var asset = tenable_ot::assets::get(vendor:'Schneider');
var vuln_cpes = {
"cpe:/h:schneider-electric:ion5000:-" :
{"family" : "ION"},
"cpe:/h:schneider-electric:ion7300:-" :
{"family" : "ION"},
"cpe:/h:schneider-electric:ion7500:-" :
{"family" : "ION"},
"cpe:/h:schneider-electric:ion7600:-" :
{"family" : "ION"},
"cpe:/h:schneider-electric:ion8650:-" :
{"family" : "ION"},
"cpe:/h:schneider-electric:ion8800:-" :
{"family" : "ION"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation