3461 matches found
Schneider Electric IGSS Data Server Access Control Error Vulnerability (CNVD-2023-29375)
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. An access control error vulnerability exists in Schneider Electric IGSS Data Server, which could be exploited by an attacker to create malicious report files in the IGSS...
Schneider Electric IGSS Data Server Data Forgery Issue Vulnerability (CNVD-2023-29371)
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. Schneider Electric IGSS Data Server is vulnerable to a data forgery issue, which could be exploited by an attacker to gain access to delete files in the IGSS project...
CVE-2023-1256
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states...
CVE-2023-1256
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states...
CVE-2023-1256 CVE-2023-1256
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states...
CVE-2023-1256
CVE-2023-1256 affects AVEVA Plant SCADA and AVEVA Telemetry Server with an improper authorization (CWE-285) vulnerability. An unauthenticated remote attacker could read data, cause DoS, and tamper with alarm states. Affected products/versions include AVEVA Plant SCADA (2023, 2020R2 Update 10 and ...
CVE-2023-1256 CVE-2023-1256
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states...
AVEVA Plant SCADA Access Anywhere 授权问题漏洞
AVEVA Plant SCADA Access Anywhere is a reliable, flexible and high-performance Supervisory Control and Data Acquisition SCADA software solution for industrial process customers from AVEVA. The true value and power of Plant SCADA can be accessed in any compatible web browser. An authorization issu...
PT-2023-7551 · Unknown · Trace Mode
Name of the Vulnerable Software and Affected Versions: TRACE MODE affected versions not specified Description: The issue is related to the unencrypted storage of credentials in the SCADA system. Exploitation of this issue could allow an attacker to modify user privileges, potentially granting...
Osprey Pump Controller 1.0.1 Unauthenticated File Disclosure
Osprey Pump Controller 1.0.1 Unauthenticated File Disclosure Vendor: ProPump and Controls, Inc. Product web page: https://www.propumpservice.com | https://www.pumpstationparts.com Affected version: Software Build ID 20211018, Production 10/18/2021 Mirage App: MirageAppManager, Release 1.0.1 Mirag...
Osprey Pump Controller 1.0.1 userName Command Injection
Osprey Pump Controller 1.0.1 userName Blind Command Injection Vendor: ProPump and Controls, Inc. Product web page: https://www.propumpservice.com | https://www.pumpstationparts.com Affected version: Software Build ID 20211018, Production 10/18/2021 Mirage App: MirageAppManager, Release 1.0.1 Mira...
Osprey Pump Controller 1.0.1 Cross Site Scripting Vulnerability
Osprey Pump Controller 1.0.1 Unauthenticated Reflected XSS Vendor: ProPump and Controls, Inc. Product web page: https://www.propumpservice.com | https://www.pumpstationparts.com Affected version: Software Build ID 20211018, Production 10/18/2021 Mirage App: MirageAppManager, Release 1.0.1 Mirage...
Osprey Pump Controller 1.0.1 Cross Site Scripting
Osprey Pump Controller 1.0.1 Unauthenticated Reflected XSS Vendor: ProPump and Controls, Inc. Product web page: https://www.propumpservice.com | https://www.pumpstationparts.com Affected version: Software Build ID 20211018, Production 10/18/2021 Mirage App: MirageAppManager, Release 1.0.1 Mirage...
CVE-2023-0595
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
CVE-2023-0595
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
Input validation
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
CVE-2023-0595
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
EcoStruxure Geo SCADA Expert 安全漏洞
EcoStruxure Geo SCADA Expert is an integrated, scalable, and reliable Supervisory Control and Data Acquisition SCADA software. A security vulnerability exists in EcoStruxure Geo SCADA Expert that stems from an improper output neutralization issue with the device's logs, which can lead to incorrec...
CVE-2023-0595
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...
PT-2023-5841 · Triangle Microworks · Triangle Microworks Scada Data Gateway
Name of the Vulnerable Software and Affected Versions: Triangle MicroWorks SCADA Data Gateway affected versions not specified Description: This issue allows remote attackers to write arbitrary files on affected installations, potentially enabling them to execute code in the context of root. The...