4118 matches found
CVE-2012-4355: Undefined Security Weakness
TCPIPSStory.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted negative integer after the opcode, triggering incorrect function-pointer processing that can lead to ...
CVE-2012-4359: Improper Input Validation
Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service invalid 0x00 write operation and daemon crash or possibly have unspecified other impact via a...
CVE-2012-4353: Improper Restriction of Operations within the Bounds of a Memory Buffer
Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a crafted port-46824 TCP packet that triggers an incorrect file-open attempt by the TCPIPSBinOpenFileFP function,...
PT-2012-5354
Name of the Vulnerable Software and Affected Versions Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.17 Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.17 Description The issue allows remote attackers to execute arbitrary code by referencing an invalid file-pointer index within a...
PT-2012-5352
Name of the Vulnerable Software and Affected Versions Winlog Pro SCADA versions prior to 2.07.18 Winlog Lite SCADA versions prior to 2.07.18 Description The issue allows remote attackers to execute arbitrary code via a crafted TCP packet sent to port 46824, containing a negative integer after the...
PT-2012-5355
Name of the Vulnerable Software and Affected Versions Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.17 Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.17 Description The issue allows remote attackers to cause a denial of service, potentially resulting in an invalid 0x00 write...
PT-2012-5356
Name of the Vulnerable Software and Affected Versions Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.18 Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.18 Description The issue is related to the lack of validation of the return value of the realloc function, which can be exploited...
PT-2012-5353
Name of the Vulnerable Software and Affected Versions Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.17 Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.17 Description The issue allows remote attackers to read arbitrary files via port 46824 TCP packets. This is achieved by specifyi...
PT-2012-5350
Name of the Vulnerable Software and Affected Versions Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.17 Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.17 Description A stack-based buffer overflow issue exists, allowing remote attackers to execute arbitrary code via a crafted TCP...
Electro Industries GaugeTech SCADA Server Detection
Binary data 6543.prm...
enteliTOUCH SCADA Server Detection
Binary data 6542.prm...
CVE-2012-3005: Undefined Security Weakness
Untrusted search path vulnerability in Invensys Wonderware InTouch 2012 and earlier, as used in Wonderware Application Server, Wonderware Information Server, Foxboro Control Software, InFusion CE/FE/SCADA, InBatch, and Wonderware Historian, allows local users to gain privileges via a Trojan horse...
Siemens Patches Stuxnet-Like SCADA Bugs
German industrial control system manufacturer Siemens announced Monday that it had patched holes in some of its products that appear to resemble holes used by the famous Stuxnet worm in 2010. If left unpatched, vulnerabilities in the company’s Simatic STEP 7 and Simatic PCS 7 software could have...
Siemens Patches Stuxnet-Like SCADA Bugs
German industrial control system manufacturer Siemens announced Monday that it had patched holes in some of its products that appear to resemble holes used by the popular Stuxnet worm in 2010. If left unpatched, vulnerabilities in the company’s Simatic STEP 7 and Simatic PCS 7 software could have...
WellinTech KingHistorian Detection
Binary data scadaappwellintechkinghistoriandetect.nbin...
CVE-2012-2515
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module aka the HTML Help component, as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1...
CVE-2012-2515
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module aka the HTML Help component, as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1...
CVE-2012-2515
CVE-2012-2515 describes multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control (KeyHelp.ocx 1.2.312) in the KeyWorks KeyHelp Module (HTML Help component). The flaws allow remote code execution via a long string passed to the (1) JumpMappedID or (2) JumpURL methods, affecti...
CVE-2012-2516
The CVE-2012-2516 issue is an ActiveX-based command-injection vulnerability in KeyHelp.ocx of GE Intelligent Platforms’ KeyWorks KeyHelp module, affecting Proficy Historian (3.1, 3.5, 4.0, 4.5), Proficy HMI/SCADA – iFIX (5.0, 5.1), Proficy Pulse 1.0, Proficy Batch Execution 5.6, and SI7 I/O Drive...
PT-2012-4075
Name of the Vulnerable Software and Affected Versions GE Intelligent Platforms Proficy Historian versions 3.1 through 4.5 Proficy HMI/SCADA iFIX versions 5.0 through 5.1 Proficy Pulse version 1.0 Proficy Batch Execution version 5.6 SI7 I/O Driver versions 7.20 through 7.42 Description The issue...