CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
COMPLETE
Integrity Impact
COMPLETE
Availability Impact
COMPLETE
AV:N/AC:M/Au:N/C:C/I:C/A:C
AI Score
Confidence
Low
EPSS
Percentile
99.4%
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.
Vendor | Product | Version | CPE |
---|---|---|---|
emc | captiva_quickscan_pro | 4.6 | cpe:2.3:a:emc:captiva_quickscan_pro:4.6:sp1:*:*:*:*:*:* |
emc | documentum_applicationxtender_desktop | 5.4 | cpe:2.3:a:emc:documentum_applicationxtender_desktop:5.4:*:*:*:*:*:*:* |
ge | intelligent_platforms_proficy_batch_execution | 5.6 | cpe:2.3:a:ge:intelligent_platforms_proficy_batch_execution:5.6:*:*:*:*:*:*:* |
ge | intelligent_platforms_proficy_historian | 3.1 | cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.1:*:*:*:*:*:*:* |
ge | intelligent_platforms_proficy_historian | 3.5 | cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.5:*:*:*:*:*:*:* |
ge | intelligent_platforms_proficy_historian | 4.0 | cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.0:*:*:*:*:*:*:* |
ge | intelligent_platforms_proficy_historian | 4.5 | cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.5:*:*:*:*:*:*:* |
ge | intelligent_platforms_proficy_hmi\/scada_ifix | 5.0 | cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_ifix:5.0:*:*:*:*:*:*:* |
ge | intelligent_platforms_proficy_hmi\/scada_ifix | 5.1 | cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\/scada_ifix:5.1:*:*:*:*:*:*:* |
ge | intelligent_platforms_proficy_pulse | 1.0 | cpe:2.3:a:ge:intelligent_platforms_proficy_pulse:1.0:*:*:*:*:*:*:* |
retrogod.altervista.org/9sg_emc_keyhelp.html
secunia.com/advisories/36905
secunia.com/advisories/36914
support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf
www.securityfocus.com/bid/36546
www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf
www.vupen.com/english/advisories/2009/2793
www.vupen.com/english/advisories/2009/2795