3468 matches found
Design/Logic Flaw
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service infinite loop via crafted input over a serial line...
CVE-2013-2793
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service infinite loop via a crafted DNP3 TCP packet...
CVE-2013-2794
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service infinite loop via crafted input over a serial line...
CVE-2013-2794
CVE-2013-2794 affects Triangle MicroWorks SCADA Data Gateway (v2.50.0309–v3.00.0616), DNP3 .NET Protocol components (v3.06.0.171–v3.15.0.369), and DNP3 ANSI C libraries (v3.06.0000–v3.15.0000). Root cause is improper input validation that can trigger an infinite loop, causing a DoS. IP-connected ...
CVE-2013-2791
MatrikonOPC SCADA DNP3 OPC Server 1.2.0 is affected by an improper input validation vulnerability (CWE-20) that can be triggered by a malformed DNP3 TCP packet from an outstation, potentially causing the master server to crash and disrupt OPC communication. The issue is exploitable remotely, with...
CVE-2013-2793
CVE-2013-2793 affects Triangle MicroWorks SCADA Data Gateway (v2.50.0309–v3.00.0616), DNP3 .NET Protocol components (v3.06.0.171–v3.15.0.369), and DNP3 ANSI C libraries (v3.06.0000–v3.15.0000). The vulnerability is improper input validation that allows an attacker to cause a denial of service (in...
CVE-2013-2791
MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service master-station daemon crash via a malformed DNP3 TCP packet from the IP address of an outstation...
Siemens WinCC Exploitable Crashes
Overview ICS-CERT Advisory ICSA-11-175-02P was originally released to the US-CERT Portal on June 24, 2011. This web page release was delayed to allow users sufficient time to download and install the update. ICS-CERT has received a report from independent security researchers Billy Rios and Terry...
Xxe
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...
CVE-2013-2796
This entry (CVE-2013-2796) describes an XML External Entity (XXE) vulnerability in Schneider Electric products: Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier. The underlying issue is improper restriction of XML entities, allowing a remote attac...
CVE-2013-2796
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service CPU and memory consumption via an XML document containing an...
Chinese Hackers Caught by US water control system Honeypots
A notorious Chinese hacker collective known as APT1 or Comment Crew, possibly linked to the Chinese Army, have been caught red handed breaking into a fake United States water control system i.e. known as a Honeypot. Kyle Wilhoit, a researcher with security company Trend Micro has just revealed th...
Chinese Hackers Caught by US water control system Honeypots
A notorious Chinese hacker collective known as APT1 or Comment Crew, possibly linked to the Chinese Army, have been caught red handed breaking into a fake United States water control system i.e. known as a Honeypot. Kyle Wilhoit, a researcher with security company Trend Micro has just revealed th...
CVE-2013-2785
Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted...
Buffer overflow
Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted...
CVE-2013-2785
CVE-2013-2785 affects GE Intelligent Platforms Proficy HMI/SCADA CIMPLICITY (WebView/CimWebServer). The vulnerability stems from improper input handling in CimWebServer’s WebView, allowing a remote attacker to execute arbitrary code by sending crafted data to TCP port 10212. Affected installation...
CVE-2013-2785
Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted...
GE Proficy DNP3 Improper Input Validation
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 24, 2013, and is now being released to the NCCIC/ICS-CERT Web site. General Electric GE Intelligent Platforms reported to NCCIC/ICS-CERT an improper input validation vulnerability in the DNP3 driver used...
Bug Bounty to Reward Researchers with Redeemable Points
IntegraXor, a manufacturer of supervisory control and data acquisition SCADA equipment, announced last week that it would implement a bug bounty program offering points redeemable for company services to researchers that disclose security vulnerabilities in their IGX SCADA system. In most bug...
ICS, SCADA Attacks Targeted and Disruptive
Honeypots and honeynets have long been used as enticements to lure hackers into a false network in order to study attacks. While long a favorite of many high-end enterprises and security researchers studying attacks against traditional IT infrastructures, a number of industrial control system...