Lucene search
+L

3468 matches found

Tenable Nessus
Tenable Nessus
added 2013/10/23 12:0 a.m.17 views

Cogent DataHub Tunnel/Mirror Service Detection

Binary data scadacogentdatahubdetection.nbin...

7.3AI score
SaveExploits0References1
zdt
zdt
added 2013/10/22 12:0 a.m.70 views

Interactive Graphical SCADA System Remote Command Injection

This Metasploit module abuses a directory traversal flaw in Interactive Graphical SCADA System v9.00. In conjunction with the traversal flaw, if opcode 0x17 is sent to the dc.exe process, an attacker may be able to execute arbitrary system commands. This module requires Metasploit:...

10CVSS6.9AI score0.66982EPSS
SaveExploits11
Packet Storm
Packet Storm
added 2013/10/22 12:0 a.m.37 views

Interactive Graphical SCADA System Remote Command Injection

This module requires Metasploit: http//metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework require 'msf/core' class Metasploit3 'Interactive Graphical SCADA System Remote Command Injection', 'Description' = %q This module abuses a directory traversal flaw in...

10CVSS0.5AI score0.66982EPSS
SaveExploits11
Exploit DB
Exploit DB
added 2013/10/22 12:0 a.m.36 views

Interactive Graphical SCADA System - Remote Command Injection (Metasploit)

This module requires Metasploit: http//metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework require 'msf/core' class Metasploit3 'Interactive Graphical SCADA System Remote Command Injection', 'Description' = %q This module abuses a directory traversal flaw in...

10CVSS5.2AI score0.66982EPSS
SaveExploits11
Metasploit
Metasploit
added 2013/10/17 7:7 p.m.70 views

Interactive Graphical SCADA System Remote Command Injection

This module abuses a directory traversal flaw in Interactive Graphical SCADA System v9.00. In conjunction with the traversal flaw, if opcode 0x17 is sent to the dc.exe process, an attacker may be able to execute arbitrary system commands. This module requires Metasploit:...

10CVSS1.3AI score0.66982EPSS
SaveExploits11
ThreatPost
ThreatPost
added 2013/10/16 2:27 p.m.15 views

SCADA ICS Bug Expose Critical Infrastructure to Attack

A trio of researchers have uncovered 25 security vulnerabilities in various supervisory control and data acquisition SCADA and industrial control system ICS protocols. The researchers, Adam Crain, Chris Sistrunk, and Adam Todorski–though Todorski has not yet been credited with finding any of the...

1AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2013/10/16 12:0 a.m.13 views

RuggedCom Rugged Operating System < 3.12.2 Multiple Security Vulnerabilities

Binary data 8027.prm...

8.3CVSS7.3AI score0.01893EPSS
SaveExploits0References5
ICS
ICS
added 2013/10/15 6:0 a.m.37 views

SpecView Directory Traversal

Overview This advisory is a follow up to the original alert titled ICS-ALERT-12-214-01 SpecView Directory Traversal that was published August 01, 2012, on the ICS-CERT Web. This advisory provides mitigation details for a vulnerability, which impacts SpecView products. Independent researcher Luigi...

5CVSS6.5AI score0.04813EPSS
SaveExploits2References10
Tenable Nessus
Tenable Nessus
added 2013/10/10 12:0 a.m.14 views

Stulz Air Conditioning SCADA server detection

Binary data 8022.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2013/10/10 12:0 a.m.14 views

Solar Log SCADA server detection

Binary data 8023.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2013/10/10 12:0 a.m.12 views

Hirschmann Automation and Control Embedded SCADA server detection

Binary data 8020.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2013/10/03 12:0 a.m.31 views

WellinTech KingView ActiveX Multiple Arbitrary File Overwrite Vulnerabilities

Binary data scadakingviewactivex.nbin...

5.8CVSS7.3AI score0.13854EPSS
SaveExploits4References2
ThreatPost
ThreatPost
added 2013/09/23 3:24 p.m.10 views

ICS Vendor Fixes Hard-Coded Credential Bugs Nearly Two Years After Advisory

Nearly two years after a security researcher published details of the hard-coded credentials that ship with a slew of industrial control system products made by Schneider Electric, the company has released updated firmware that fix the problems. The vulnerabilities, which were discovered by...

7.7AI score
SaveExploits0References4
Check Point Advisories
Check Point Advisories
added 2013/09/22 12:0 a.m.43 views

Procyon Core Server HMI Memory Corruption SCADA Remote Code Execution (CVE-2011-3322)

A remote overflow vulnerability has been reported in Procyon Core Server HMI service...

3.4AI score0.65312EPSS
SaveExploits5
Check Point Advisories
Check Point Advisories
added 2013/09/15 12:0 a.m.16 views

Scada Engine BACnet OPC Client SCADA Remote Code Execution (CVE-2010-4740)

A buffer overflow vulnerability has been reported in SCADA Engine's BACnet OPC Client. The vulnerability is due to a boundary check error. A remote attacker may exploit this issue by sending specially crafted malicious file to be opened using the affected product. Successful exploitation could...

9.3CVSS7.5AI score0.41619EPSS
SaveExploits3
NVD
NVD
added 2013/09/09 11:39 a.m.21 views

CVE-2013-2794

Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service infinite loop via crafted input over a serial line...

4.9CVSS6.5AI score0.00317EPSS
SaveExploits0References2
NVD
NVD
added 2013/09/09 11:39 a.m.16 views

CVE-2013-2791

MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service master-station daemon crash via a malformed DNP3 TCP packet from the IP address of an outstation...

7.1CVSS6.6AI score0.0126EPSS
SaveExploits0References2
NVD
NVD
added 2013/09/09 11:39 a.m.29 views

CVE-2013-2793

Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service infinite loop via a crafted DNP3 TCP packet...

7.8CVSS6.6AI score0.0147EPSS
SaveExploits0References2
Prion
Prion
added 2013/09/09 11:39 a.m.14 views

Design/Logic Flaw

MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service master-station daemon crash via a malformed DNP3 TCP packet from the IP address of an outstation...

7.1CVSS7.1AI score0.0126EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2013/09/09 11:39 a.m.22 views

Code injection

Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service infinite loop via a crafted DNP3 TCP packet...

7.8CVSS7.1AI score0.0147EPSS
SaveExploits0References2Affected Software3
Rows per page
Query Builder