Lucene search
+L

3466 matches found

NVD
NVD
added 2020/01/06 11:15 p.m.24 views

CVE-2019-6854

A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the...

7.8CVSS7.6AI score0.00167EPSS
SaveExploits0References1
CVE
CVE
added 2020/01/06 10:56 p.m.158 views

CVE-2019-6854

CVE-2019-6854 concerns an improper authentication vulnerability in EcoStruxure Geo SCADA Expert (ClearSCADA). The issue is located in a folder within the product and, if exploited by a low-privilege user who has OS filesystem access, could allow deletion or modification of database, settings, or ...

7.8CVSS7.6AI score0.00167EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/01/06 10:56 p.m.26 views

CVE-2019-6854

A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert ClearSCADA -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the...

7.7AI score0.00167EPSS
SaveExploits0References1
Check Point Advisories
Check Point Advisories
added 2020/01/01 12:0 a.m.30 views

LAquis SCADA LGX Out-Of-Bounds Write (CVE-2018-18986)

An out-of-bounds write vulnerability exists in the LAquis SCADA. This vulnerability is due to improper validation of user-supplied data when parsing the LGX report file. Successful exploitation would result in a denial of service condition...

8.3CVSS3.6AI score0.02668EPSS
SaveExploits0
Gitee
Gitee
added 2019/12/09 11:14 p.m.6 views

icsmaster

This repository, 'icsmaster', is an ICS/SCADA security resource collection. It contains various tools and scripts for identifying and exploiting vulnerabilities in industrial control systems. The repository includes a list of dorks search terms for finding vulnerable systems, as well as a...

7.1AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/12/04 12:0 a.m.32 views

3S CODESYS CmpWebServerHandlerV3 Heap-based Buffer Overflow

Binary data scadacodesys2019-10.nbin...

9.8CVSS7.3AI score0.01961EPSS
SaveExploits1References2
Pen Test Partners Blog
Pen Test Partners Blog
added 2019/12/03 12:18 p.m.61 views

Analysing the Attack Surface of an Industrial Data Acquisition Device

Introduction The Data Station Plus from Red Lion Controls was handed to me to analyse the attack surface. The device is designed to connect to SCADA data acquisition devices over Modbus, Profibus, etc. by Serial or Ethernet connection. Data is collected and recorded to a local compact flash card...

7.1AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
added 2019/11/25 12:0 a.m.25 views

Advantech WebAccess SCADA Buffer Overflow (CVE-2019-3953)

A stack buffer overflow exists in Advantech WebAccess SCADA. The vulnerability is due to improper validation of user-supplied data in the request submitted to the target server with IOCTL 10012. Successful exploitation could lead to arbitrary code execution under context of Administrator...

7.5CVSS4.1AI score0.03988EPSS
SaveExploits1
Check Point Advisories
Check Point Advisories
added 2019/11/25 12:0 a.m.43 views

Advantech WebAccess SCADA Buffer Overflow (CVE-2019-6550)

A stack-based buffer overflow vulnerability exists in Advantech WebAccess. The vulnerability is due to a lack of boundary checks while copying user-supplied data into a stack-based buffer within bwstwww.exe. Successful exploitation could lead to arbitrary code execution under context of...

7.5CVSS3.6AI score0.06092EPSS
SaveExploits0
exploitpack
exploitpack
added 2019/11/18 12:0 a.m.46 views

Open Proficy HMI-SCADA 5.0.0.25920 - Password Denial of Service (PoC)

Open Proficy HMI-SCADA 5.0.0.25920 - Password Denial of Service PoC Exploit Title: Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service PoC Discovery by: Luis Martinez Discovery Date: 2019-11-16 Vendor Homepage: https://apps.apple.com/us/app/proficyscada/id525792142 Software Link: Ap...

7.3AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
added 2019/11/18 12:0 a.m.32 views

LAquis SCADA Web Server Command Injection (CVE-2018-18996)

A command injection vulnerability exists in LAquis SCADA. The vulnerability is due to improper handling of parameter submitted in requests. Successful exploitation results in the execution of arbitrary commands with the privileges of the web server process...

7.5CVSS2.6AI score0.02462EPSS
SaveExploits0
Exploit DB
Exploit DB
added 2019/11/18 12:0 a.m.155 views

Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service (PoC)

Exploit Title: Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service PoC Discovery by: Luis Martinez Discovery Date: 2019-11-16 Vendor Homepage: https://apps.apple.com/us/app/proficyscada/id525792142 Software Link: App Store for iOS devices GE Intelligent Platforms, Inc. Tested Versio...

5.3AI score
SaveExploits0
Packet Storm
Packet Storm
added 2019/11/18 12:0 a.m.136 views

Open Proficy HMI-SCADA 5.0.0.25920 Denial Of Service

Exploit Title: Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service PoC Discovery by: Luis Martinez Discovery Date: 2019-11-16 Vendor Homepage: https://apps.apple.com/us/app/proficyscada/id525792142 Software Link: App Store for iOS devices GE Intelligent Platforms, Inc. Tested Versio...

7.4AI score
SaveExploits0
zdt
zdt
added 2019/11/18 12:0 a.m.83 views

Open Proficy HMI-SCADA 5.0.0.25920 - (Password) Denial of Service Exploit

Exploit Title: Open Proficy HMI-SCADA 5.0.0.25920 - 'Password' Denial of Service PoC Discovery by: Luis Martinez Vendor Homepage: https://apps.apple.com/us/app/proficyscada/id525792142 Software Link: App Store for iOS devices GE Intelligent Platforms, Inc. Tested Version: 5.0.0.25920 Vulnerabilit...

7.4AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
added 2019/11/04 12:0 a.m.53 views

LAquis SCADA LGX Report Arbitrary File Write (CVE-2018-18988)

An arbitrary file write vulnerability exists in LAquis SCADA LGX report. Successful exploitation of this vulnerability could result in arbitrary file write and possible arbitrary code execution...

8.3CVSS3.3AI score0.02572EPSS
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2019/10/29 12:0 a.m.5 views

Vulnerability of systems for data collection and process control in Citect SCADA and Mitsubishi MX4 SCADA: This vulnerability arises due to buffer overflow in the login input field, allowing attackers to execute arbitrary code.

The vulnerability of systems for data collection and process control in Citect SCADA and Mitsubishi MX4 SCADA arises due to an overflow in the input field for the login string. Exploiting this vulnerability allows a attacker to execute arbitrary code using a long input string...

5.3CVSS6AI score0.00471EPSS
SaveExploits0References3Affected Software2
BDU FSTEC
BDU FSTEC
added 2019/10/29 12:0 a.m.9 views

Vijeo Citect, CitectSCADA, and PowerLogic SCADA systems are vulnerable to data collection and industrial automation process control. This vulnerability stems from deficiencies in access control for certain functions, allowing attackers to read arbitrary files, send HTTP requests, or cause service interruptions.

The vulnerabilities of systems for data collection and process control in Vijeo Citect, CitectSCADA, and PowerLogic SCADA are related to deficiencies in access control for certain functions. Exploiting these vulnerabilities can allow attackers to read arbitrary files, send HTTP requests, or cause...

8.4CVSS5.7AI score0.00732EPSS
SaveExploits0References4Affected Software3
CNVD
CNVD
added 2019/10/22 12:0 a.m.8 views

IEC870IP driver buffer overflow vulnerability

AVEVA Vijeo Citect and AVEVA CitectSCADA are a suite of data acquisition and monitoring system SCADA software. iec870IP is one of the drivers. A buffer overflow vulnerability exists in the IEC870IP driver v4.14.02 and earlier versions, which can be exploited by an attacker to cause a server-side...

7.5CVSS7.2AI score0.01297EPSS
SaveExploits0References1
ICS
ICS
added 2019/10/17 12:0 a.m.251 views

AVEVA Vijeo Citect and Citect SCADA (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit --------- Begin Update A Part 1 of 5 --------- Vendor: AVEVA and Schneider Electric Equipment: AVEVA’s Vijeo Citect and Citect SCADA; Schneider Electric’s Power SCADA Operation --------- End Update A Part...

7.5CVSS8AI score0.01297EPSS
SaveExploits0References5
Pen Test Partners Blog
Pen Test Partners Blog
added 2019/10/10 2:30 p.m.118 views

Operational Technology Networks or OT

Operational Technology Networks or OT Notes: It’s mixing up OT with maritime, so probably isn’t suitable as is. The first section is really good, very relevant. We can use all of that. Once we get in to NMEA data, then it goes off topic. I suggest: Network equipment such as the Scalance Then a...

7.5CVSS0.4AI score0.19856EPSS
SaveExploits4
Rows per page
Query Builder