3466 matches found
Command Execution Vulnerability in Advantech WebAccess/SCADA
Advantech WebAccess/SCADA is a set of SCADA software based on browser architecture from Advantech, Taiwan, China. A command execution vulnerability exists in Advantech WebAccess/SCADA, which can be exploited by an attacker to execute malicious code...
PoetRAT: Python RAT uses COVID-19 lures to target Azerbaijan public and private sectors
By Warren Mercer, Paul Rascagneres and Vitor Ventura. News summaryAzerbaijan government and energy sector likely targeted by an unknown actor.From the energy sector, the actor demonstrates interest in SCADA systems related to wind turbines.The actor uses Word documents to drop malware that allows...
COVID-Themed Lures Target SCADA Sectors With Data Stealing Malware
A new malware campaign has been found using coronavirus-themed lures to strike government and energy sectors in Azerbaijan with remote access trojans RAT capable of exfiltrating sensitive documents, keystrokes, passwords, and even images from the webcam. The targeted attacks employ Microsoft Word...
COVID-Themed Lures Target SCADA Sectors With Data Stealing Malware
A new malware campaign has been found using coronavirus-themed lures to strike government and energy sectors in Azerbaijan with remote access trojans RAT capable of exfiltrating sensitive documents, keystrokes, passwords, and even images from the webcam. The targeted attacks employ Microsoft Word...
(Pwn2Own) Triangle MicroWorks SCADA Data Gateway DNP3 Type Confusion Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of data set elements. The issue results from the lac...
(Pwn2Own) Triangle Microworks SCADA Data Gateway DNP3 GET_FILE_INFO Stack-based Buffer Overflow Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle Microworks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists with the handling of opcodes for GETFILEINFO. The issue results from the...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
Stack overflow
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
Design/Logic Flaw
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
CVE-2020-10611
CVE-2020-10611 is a real, externally exploitable type-confusion vulnerability in Triangle MicroWorks SCADA Data Gateway (DNP3 Data Sets). The Red Hat and NVD entries confirm it affects versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122, enabling remote code execution with no authentication required...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway is affected by CVE-2020-10613 (and related CVEs) in versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122 due to an out-of-bounds read from improper validation of user-supplied data in DNP3 Data Sets. The vulnerability allows remote attackers to disclose sensitiv...
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
CVE-2020-10615
CVE-2020-10615 affects Triangle MicroWorks SCADA Data Gateway, specifically versions 3.02.0697–4.0.122 and 2.41.0213–4.0.122. The root cause is improper validation of the length of user-supplied data prior to copying into a fixed-length stack-based buffer, causing a stack-based buffer overflow. T...
CVE-2020-6992
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an...