Lucene search
+L

3461 matches found

OSV
OSV
added 2022/02/11 6:15 p.m.8 views

CVE-2021-22802

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.ex...

9.8CVSS6.4AI score0.20165EPSS
SaveExploits0References1
OSV
OSV
added 2022/02/11 6:15 p.m.7 views

CVE-2021-22823

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...

9.1CVSS5.9AI score0.21388EPSS
SaveExploits0References1
OSV
OSV
added 2022/02/11 6:15 p.m.5 views

CVE-2021-22824

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...

7.5CVSS5.8AI score0.14241EPSS
SaveExploits0References1
Prion
Prion
added 2022/02/11 6:15 p.m.15 views

Design/Logic Flaw

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...

5CVSS7.4AI score0.14241EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2022/02/11 6:15 p.m.15 views

Design/Logic Flaw

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...

7.5CVSS9.6AI score0.01943EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2022/02/11 6:15 p.m.18 views

Remote code execution

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.ex...

7.5CVSS9.6AI score0.20165EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2022/02/11 6:15 p.m.17 views

Authentication flaw

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...

5CVSS9.1AI score0.0085EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2022/02/11 6:15 p.m.14 views

Authentication flaw

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...

5CVSS9.1AI score0.21388EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2022/02/11 6:15 p.m.19 views

Design/Logic Flaw

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphica...

5CVSS7.4AI score0.01294EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/02/11 5:40 p.m.32 views

CVE-2021-22824

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...

7.7AI score0.14241EPSS
SaveExploits0References1
CVE
CVE
added 2022/02/11 5:40 p.m.62 views

CVE-2021-22824

The CVE-2021-22824 entry concerns the Schneider Electric Interactive Graphical SCADA System Data Collector (dc.exe) with affected versions up to 15.0.0.21320 and earlier. The root cause is a Buffer Copy without Checking Size of Input (CWE-120), due to missing length checks on user-supplied data i...

7.5CVSS7.4AI score0.14241EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/02/11 5:40 p.m.20 views

CVE-2021-22823

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...

9.3AI score0.21388EPSS
SaveExploits0References1
CVE
CVE
added 2022/02/11 5:40 p.m.58 views

CVE-2021-22823

CVE-2021-22823 affects Schneider Electric IGSS Interactive Graphical SCADA System Data Collector (dc.exe) on v15.0.0.21320 and earlier. It is a CWE-306 Missing Authentication for Critical Function vulnerability caused by lack of validation of network messages, which could lead to deletion of arbi...

9.1CVSS9.1AI score0.21388EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/02/11 5:40 p.m.25 views

CVE-2021-22805

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...

9.3AI score0.0085EPSS
SaveExploits0References1
CVE
CVE
added 2022/02/11 5:40 p.m.75 views

CVE-2021-22805

Schneider Electric IGSS DC (dc.exe) up to v15.0.0.21243 is affected by CVE-2021-22805 (CWE-306) due to missing authentication for a critical function caused by lack of validation of network messages. This could allow a remote attacker to delete arbitrary files in the context of the running user. ...

9.1CVSS9.1AI score0.0085EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/02/11 5:40 p.m.20 views

CVE-2021-22804

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphica...

7.5AI score0.01294EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/02/11 5:40 p.m.28 views

CVE-2021-22802

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.ex...

9.9AI score0.20165EPSS
SaveExploits0References1
CVE
CVE
added 2022/02/11 5:40 p.m.80 views

CVE-2021-22802

Schneider Electric IGSS Data Collector (dc.exe), affected in IGSS v15.0.0.21243 and earlier, is vulnerable to a CWE-120 buffer overflow due to missing length checks on user-supplied data while processing a network-constructed message. This can lead to remote code execution with the dc.exe process...

9.8CVSS9.6AI score0.20165EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/02/11 5:40 p.m.25 views

CVE-2021-22803

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...

9.9AI score0.01943EPSS
SaveExploits0References1
CVE
CVE
added 2022/02/11 5:40 p.m.84 views

CVE-2021-22803

Schneider Electric IGSS DC module (dc.exe, v15.0.0.21243 and prior) is affected by CVE-2021-22803: Unrestricted Upload of File with Dangerous Type, enabling remote code execution by writing arbitrary files to folders in the DC module context via network messages. Root cause: lack of validation du...

9.8CVSS9.6AI score0.01943EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder