ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 - Remote File CRUD

Exploit Title: CL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File CRUD Exploit Author: LiquidWorm !/usr/bin/env python3 -- coding: utf-8 -- ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File CRUD Vendor: Industrial Control Links, Inc. Product web page:...

9.1CVSS8.7AI score0.37295EPSS
SaveExploits5
CNNVD
CNNVD
added 2022/02/22 12:0 a.m.7 views

Industrial Control Links Icl ScadaFlex II Scada Controllers 访问控制错误漏洞

Industrial Control Links Icl ScadaFlex II Scada Controllers is a set of Web Scada controllers from Industrial Control Links, Inc. It is designed to provide a complete Scada system at the lowest possible cost. An Access Control Error vulnerability exists in ICL ScadaFlex II SCADA Controllers...

9.1CVSS8.5AI score0.37295EPSS
SaveExploits5References7
Packet Storm
Packet Storm
added 2022/02/22 12:0 a.m.241 views

ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File Modification

!/usr/bin/env python3 -- coding: utf-8 -- ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File CRUD Vendor: Industrial Control Links, Inc. Product web page: http://www.iclinks.com Product datasheet:...

0.5AI score0.37295EPSS
SaveExploits5
0day.today
0day.today
added 2022/02/22 12:0 a.m.310 views

ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File Modification Exploit

ICL ScadaFlex II SCADA Controllers SC-1/SC-2 version 1.03.07 is vulnerable to unauthenticated file write/overwrite and deletion. This allows an attacker to execute critical file CRUD operations on the device that can potentially allow system access and impact availability. !/usr/bin/env python3 -...

9.1CVSS0.8AI score0.37295EPSS
SaveExploits5
Zero Science Lab
Zero Science Lab
added 2022/02/22 12:0 a.m.442 views

ICL ScadaFlex II SCADA Controllers SC-1/SC-2 1.03.07 Remote File CRUD

Summary Scadaflex II controllers are 100% web based for both configuration and user interface. No applications are required other than any standard web browser. They are easily supported by remote access over the Internet or a cellular link. Scadaflex II controllers support industry standard wire...

9.1CVSS7.6AI score0.37295EPSS
SaveExploits5
CNVD
CNVD
added 2022/02/18 12:0 a.m.54 views

Schneider Electric Interactive Graphical SCADA System Initialization Error Vulnerability

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An initialization error vulnerability exists in the Schneider Electric Interactive Graphical...

7.5CVSS7.2AI score0.01273EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/18 12:0 a.m.47 views

Schneider Electric Interactive Graphical Scada System Integer Overflow Vulnerability

The Schneider Electric Interactive Graphical Scada System Igss is a Scada system for monitoring and controlling industrial processes from Schneider Electric, France. The Schneider Electric Interactive Graphical Scada System has an integer overflow vulnerability that can be exploited by an attacke...

9.8CVSS9.7AI score0.02227EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/15 12:0 a.m.46 views

Schneider Electric Interactive Graphical SCADA System Access Control Error Vulnerability (CNVD-2022-13067)

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An access control error vulnerability exists in the Schneider Electric Interactive Graphical...

9.1CVSS9.2AI score0.21388EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/13 12:0 a.m.52 views

Schneider Electric Interactive Graphical SCADA System Path Traversal Vulnerability (CNVD-2022-13068)

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. A path traversal vulnerability exists in the Schneider Electric Interactive Graphical SCADA...

9.8CVSS9.7AI score0.03463EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/13 12:0 a.m.55 views

Schneider Electric Interactive Graphical SCADA System Out-of-Bounds Read Vulnerability

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An out-of-bounds read vulnerability exists in the Schneider Electric Interactive Graphical SCAD...

7.5CVSS7.3AI score0.19255EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/13 12:0 a.m.43 views

Schneider Electric Interactive Graphical SCADA System Authorization Issues Vulnerability

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An authorization issue vulnerability exists in the Schneider Electric Interactive Graphical SCA...

7.5CVSS7.6AI score0.01206EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/13 12:0 a.m.51 views

Schneider Electric Interactive Graphical SCADA System Buffer Overflow Vulnerability (CNVD-2022-13069)

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Schneider Electric Interactive Graphical SCADA System suffers from a buffer overflow...

9.8CVSS9.9AI score0.44559EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/13 12:0 a.m.40 views

Schneider Electric Interactive Graphical Scada System Out-of-Bounds Read Vulnerability (CNVD-2022-13070)

The Schneider Electric Interactive Graphical Scada System is a Scada system for monitoring industrial processes from Schneider Electric, France. An out-of-bounds read vulnerability exists in the Schneider Electric Interactive Graphical Scada System, which can be exploited by an attacker to cause ...

7.5CVSS7.3AI score0.18178EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/11 6:15 p.m.27 views

CVE-2021-22805

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...

9.1CVSS0.0085EPSS
SaveExploits0References1
OSV
OSV
added 2022/02/11 6:15 p.m.5 views

CVE-2021-22804

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphica...

7.5CVSS5.9AI score0.01294EPSS
SaveExploits0References1
OSV
OSV
added 2022/02/11 6:15 p.m.6 views

CVE-2021-22805

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...

9.1CVSS5.9AI score0.0085EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/11 6:15 p.m.21 views

CVE-2021-22802

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.ex...

9.8CVSS0.20165EPSS
SaveExploits0References1
OSV
OSV
added 2022/02/11 6:15 p.m.4 views

CVE-2021-22803

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...

9.8CVSS6.4AI score0.01943EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/11 6:15 p.m.26 views

CVE-2021-22824

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...

7.5CVSS0.14241EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/11 6:15 p.m.34 views

CVE-2021-22803

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...

9.8CVSS0.01943EPSS
SaveExploits0References1