CVE-2014-2250
CVE-2014-2250 concerns Siemens SIMATIC S7-1200 CPUs with firmware before 4.0, where the PRNG has insufficient entropy. This weaknesses can enable remote attackers to defeat cryptographic protections and hijack sessions via unspecified vectors. Public material ties this to the S7-1200 family and n...
CVE-2014-2252
Summary (CVE-2014-2252) : Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 are affected by a vulnerability that allows remote attackers to cause a denial of service (defect-mode transition) by sending crafted PROFINET packets. The issue is tied to improper handling that enables ...
CVE-2014-2254
CVE-2014-2254 affects Siemens SIMATIC S7-1200 CPU PLCs with firmware prior to 4.0. The vulnerability allows remote DoS (defect-mode transition) by sending crafted HTTP packets to the device’s web server (Port 80/443). Root cause is related to improper handling within the device’s HTTP interface, ...
CVE-2014-2256
CVE-2014-2256 affects Siemens SIMATIC S7-1200 CPU PLCs with firmware before 4.0. The vulnerability is due to improper input validation in the device’s handling of packets, enabling a remote attacker to trigger a defect-mode transition and cause a denial of service via crafted ISO-TSAP packets. De...
CVE-2014-2258
CVE-2014-2258 affects Siemens SIMATIC S7-1200 CPU PLCs with firmware before 4.0. A crafted HTTPS packet can trigger a defect-mode transition, causing a denial of service. The issue is distinct from CVE-2014-2259. The vulnerability is triggered via remote network access to the device’s HTTPS handl...
CVE-2014-2250
The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...
CVE-2014-2256
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257...
CVE-2014-2258: Undefined Security Weakness
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259...
CVE-2014-2252: Undefined Security Weakness
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...
CVE-2014-2256: Undefined Security Weakness
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257...
CVE-2014-2250: Undefined Security Weakness
The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...
CVE-2014-2254: Undefined Security Weakness
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...
PT-2014-1954
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue allows remote attackers to cause a denial of service, resulting in the device transitioning to defect mode, followed by a cold restart. This is achieved b...
Siemens SIMATIC S7-1200多个漏洞
CVE ID: CVE-2014-2249,CVE-2014-2250,CVE-2014-2252,CVE-2014-2254,CVE-2014-2256,CVE-2014-2258 SIMATIC S7-1200是可编程控制器,可实现简单却高度精确的自动化任务。 Siemens SIMATIC S7-1200 4.0.0之前版本在实现上存在多个漏洞,可被恶意利用执行跨站请求伪造、劫持用户会话、造成拒绝服务。 1、向TCP端口443发送特制的数据包造成的错误可造成设备进入defect模式。 2、随机生成器内弱熵相关错误,可导致劫持另外用户的会话。...
PT-2014-1002
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue allows remote attackers to cause a denial of service, resulting in a defect-mode transition, via crafted ISO-TSAP packets. Exploitation can be achieved by...
PT-2014-1178
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue allows a remote attacker to cause a denial of service, resulting in the device entering defect mode, by sending crafted HTTP packets to the TCP port 80...
PT-2014-1003
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue concerns a problem with the random-number generator in the authentication handler of the web server, which lacks sufficient entropy. This makes it easier...
PT-2014-1004
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue allows remote attackers to cause a denial of service, resulting in the device transitioning to defect mode, which lasts until a hardware reset is performe...
CVE-2014-2246
Cross-site scripting XSS vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...
CVE-2014-2248
Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors...