2326 matches found
CVE-2014-2909
CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors...
CVE-2014-2909
CVE-2014-2909 describes a CRLF injection vulnerability in the integrated web server of Siemens SIMATIC S7-1200 CPU family (versions 2.x and 3.x) that could enable HTTP header injection. The issue is categorized as an HTTP response splitting risk with a CVSS v2 base score of 5.8 (network access, m...
CVE-2014-2909: Improper Control of Generation of Code
CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors...
PT-2014-4954
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU devices versions 2.x through 3.x Description A cross-site scripting XSS issue exists in the integrated web server, allowing remote attackers to inject arbitrary web script or HTML. This could potentially lead to...
CVE-2014-2908: Improper Neutralization of Input During Web Page Generation
Cross-site scripting XSS vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...
PT-2014-1179
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU devices versions 2.x through 3.x Description The issue concerns a CRLF injection vulnerability in the integrated web server of the affected devices. This vulnerability allows remote attackers to inject arbitrary HTT...
ICS-CERT Warns of Heartbleed Vulnerabilities in Siemens Gear
A number of ICS products from Siemens and Innominate are vulnerable to the OpenSSL heartbleed flaw, some of which do not have updates available yet. The list of products affected by the heartbleed vulnerability continues to grow by the day, with OpenVPN being one of the latest. A researcher on...
Siemens SIMATIC S7-1200 Multiple DoS Vulnerabilities (SSA-654382)
Siemens SIMATIC S7-1200 devices are prone to multiple denial of service DoS vulnerabilities. Copyright C 2014 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later...
CVE-2014-2250
The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...
CVE-2014-2252
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...
CVE-2014-2254
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...
CVE-2014-2258
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259...
CVE-2014-2256
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257...
Code injection
The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...
Design/Logic Flaw
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257...
Design/Logic Flaw
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...
Design/Logic Flaw
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...
CVE-2014-2252
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...
CVE-2014-2254
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...
CVE-2014-2258
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259...