Lucene search
+L

901 matches found

NVD
NVD
•added 2019/09/17 8:15 p.m.•38 views

CVE-2019-6810

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol...

8.8CVSS8.8AI score0.01729EPSS
SaveExploits0References2
Prion
Prion
•added 2019/09/17 8:15 p.m.•26 views

Improper access control

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol...

6.5CVSS8.7AI score0.01729EPSS
SaveExploits0References2
Prion
Prion
•added 2019/09/17 8:15 p.m.•26 views

Design/Logic Flaw

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on por...

5CVSS8.5AI score0.01401EPSS
SaveExploits0References2
CVE
CVE
•added 2019/09/17 7:56 p.m.•153 views

CVE-2019-6813

The CVE-2019-6813 vulnerability affects Schneider Electric BMXNOR0200H Ethernet/Serial RTU modules and Modicon M340 controllers (all firmware versions). It is a CWE-754 improper check for unusual or exceptional conditions that could cause a denial of service when truncated SNMP packets are receiv...

7.8CVSS7.5AI score0.02084EPSS
SaveExploits0References3Affected Software1
CVE
CVE
•added 2019/09/17 7:52 p.m.•154 views

CVE-2019-6810

CVE-2019-6810 affects Schneider Electric BMXNOR0200H Ethernet/Serial RTU module (all firmware versions). The vulnerability is an improper access control that could allow unauthorized users to execute commands when using IEC 60870-5-104. Impact is described as potential remote command execution wi...

8.8CVSS8.7AI score0.01729EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2019/09/17 7:22 p.m.•142 views

CVE-2019-6831

CVE-2019-6831 affects the BMXNOR0200H Ethernet/Serial RTU module (all firmware versions), causing disconnection of active connections when an unusually high number of IEC 60870-5-104 packets are received on port 2404/TCP. Affected CVSS: v3.1 base score 8.6 (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H). E...

8.6CVSS8.5AI score0.01401EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2019/09/17 7:22 p.m.•54 views

CVE-2019-6831

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on por...

8.6AI score0.01401EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/09/17 12:00 a.m.•4 views

CVE-2019-6831: Improper Check for Unusual or Exceptional Conditions

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on por...

8.6CVSS7.7AI score0.01401EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/09/17 12:00 a.m.•5 views

CVE-2019-6810: Improper Access Control

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol...

8.8CVSS7.8AI score0.01729EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/09/17 12:00 a.m.•6 views

CVE-2019-6813: Improper Check for Unusual or Exceptional Conditions

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions and Modicon M340 controller all firmware versions, which could cause denial of service when truncated SNMP packets on port 161/UDP are received by...

7.8CVSS7.2AI score0.02084EPSS
SaveExploits0References3
CNVD
CNVD
•added 2019/08/15 12:00 a.m.•15 views

Mitsubishi Electric smartRTU and Inea ME-RTU Operating System Command Injection Vulnerability

Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. An operating system command injection vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and...

10CVSS7.9AI score0.58361EPSS
SaveExploits3References1
Exploit DB
Exploit DB
•added 2019/08/12 12:00 a.m.•295 views

Mitsubishi Electric smartRTU / INEA ME-RTU - Unauthenticated OS Command Injection Bind Shell

!/usr/bin/python Exploit Title: Mitsubishi Electric smartRTU & INEA ME-RTU Unauthenticated OS Command Injection Date: 29 June 2019 Exploit Author: @xerubus | mogozobo.com Vendor Homepage: https://eu3a.mitsubishielectric.com/fa/en/products/cnt/plcccl/items/smartRTU/local Vendor Homepage:...

10CVSS8.4AI score0.58361EPSS
SaveExploits3
exploitpack
exploitpack
•added 2019/08/12 12:00 a.m.•62 views

Mitsubishi Electric smartRTU INEA ME-RTU - Unauthenticated Configuration Download

Mitsubishi Electric smartRTU INEA ME-RTU - Unauthenticated Configuration Download !/usr/bin/python Exploit Title: Mitsubishi Electric smartRTU & INEA ME-RTU Unauthenticated Configuration Download Date: 29 June 2019 Exploit Author: @xerubus | mogozobo.com Vendor Homepage:...

5CVSS1.1AI score0.41847EPSS
SaveExploits3
exploitpack
exploitpack
•added 2019/08/12 12:00 a.m.•91 views

Mitsubishi Electric smartRTU INEA ME-RTU - Unauthenticated OS Command Injection Bind Shell

Mitsubishi Electric smartRTU INEA ME-RTU - Unauthenticated OS Command Injection Bind Shell !/usr/bin/python Exploit Title: Mitsubishi Electric smartRTU & INEA ME-RTU Unauthenticated OS Command Injection Date: 29 June 2019 Exploit Author: @xerubus | mogozobo.com Vendor Homepage:...

10CVSS1AI score0.58361EPSS
SaveExploits3
Exploit DB
Exploit DB
•added 2019/08/12 12:00 a.m.•238 views

Mitsubishi Electric smartRTU / INEA ME-RTU - Unauthenticated Configuration Download

!/usr/bin/python Exploit Title: Mitsubishi Electric smartRTU & INEA ME-RTU Unauthenticated Configuration Download Date: 29 June 2019 Exploit Author: @xerubus | mogozobo.com Vendor Homepage: https://eu3a.mitsubishielectric.com/fa/en/products/cnt/plcccl/items/smartRTU/local Vendor Homepage:...

7.5CVSS7.3AI score0.41847EPSS
SaveExploits3
BDU FSTEC
BDU FSTEC
•added 2019/06/18 12:00 a.m.•15 views

The vulnerability of the RTU module’s microprogramming software, Modicon BMXNOR0200H, arises from the presence of embedded authentication data. This allows a hacker to gain access to the FTP service.

The vulnerability of the RTU module’s microprogramming software, Modicon BMXNOR0200H, is related to the presence of embedded authentication data. Exploiting this vulnerability could allow a malicious actor to gain access to the FTP service remotely...

7.2CVSS5.5AI score0.01143EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•24 views

Schneider Electric ION7650 RTU Detection

Binary data 761658.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•6 views

Schneider Electric ION7650 RTU Detection

Binary data 761841.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•15 views

Yokogawa FCN-RTU Communications Adapter Detection

Binary data 758130.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•12 views

Schneider Electric ION7650 RTU Detection

Binary data 761824.prm...

7.3AI score
SaveExploits0
Rows per page