Synergy Systems & Solutions HUSKY RTU 6049-E70 Access Control Error Vulnerability (CNVD-2020-25373)
Synergy Systems & Solutions HUSKY RTU 6049-E70 is a Remote Terminal Unit RTU from Synergy Systems & Solutions, India. The Synergy Systems & Solutions HUSKY RTU 6049-E70 is vulnerable to an access control error that can be exploited by an attacker to view the network configuration via SNMP...
CVE-2019-20045
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and...
CVE-2019-20045
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and...
CVE-2019-20046
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue...
Design/Logic Flaw
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue...
CVE-2019-20045
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and...
CVE-2019-20045
CVE-2020-7800 (RH) concerns Synergy Systems & Solutions HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The Red Hat notes describe an Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability where specially crafted TCP packets can cause the device to shut down or reboot an...
CVE-2019-20046
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue...
CVE-2019-20046
The CVE-2019-20046 entry concerns Synergy Systems & Solutions HUSKY RTU 6049-E70 firmware (versions 5.0 and earlier). The root cause is insufficient authentication, potentially allowing an attacker to read sensitive information or execute arbitrary code. Publicly documented impact is high-priorit...
CVE-2019-20045: Improper Input Validation
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and...
CVE-2019-20046: Improper Authentication
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue...
Schneider Electric Modicon Ethernet Serial RTU
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: Modicon BMXNOR0200H Vulnerabilities: Improper Check for Unusual or Exceptional Conditions, Improper Access Control 2. RISK EVALUATION Successful exploitation of these...
Unspecified Vulnerability in Mitsubishi Electric smartRTUs and Inea ME-RTUs
Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A security vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA ME-RTU version...
Mitsubishi Electric smartRTU and Inea ME-RTU Information Disclosure Vulnerability
Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A security vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA ME-RTU version...
Mitsubishi Electric smartRTU and Inea ME-RTU Password Plaintext Storage Vulnerability
Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A password plaintext storage vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and...
Mitsubishi Electric smartRTU and Inea ME-RTU Cross-Site Scripting Vulnerability
Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A cross-site scripting vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA...
Mitsubishi Electric smartRTU and Inea ME-RTU Trust Management Issue Vulnerability
Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. A trust management issue vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and earlier and INEA...
CVE-2019-14931
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to t...
CVE-2019-14931
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to t...
CVE-2019-14930
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin...