Lucene search
+L

255 matches found

Tenable Nessus
Tenable Nessus
•added 2022/02/07 12:00 a.m.•31 views

Hitachi Energy Relion 670, 650 and SAM600-IO Improper Input Validation (CVE-2021-27196)

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 TEGO1, MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce th...

7.5CVSS7.1AI score0.01575EPSS
SaveExploits0References9
ICS
ICS
•added 2021/12/07 12:00 a.m.•50 views

Hitachi Energy RTU500 OpenLDAP

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 Series Vulnerabilities: Type Confusion, Reachable Assertion 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a denial-of-service condition...

7.5CVSS7AI score0.11968EPSS
SaveExploits0References4
ICS
ICS
•added 2021/12/02 12:00 a.m.•48 views

Hitachi Energy RTU500 series BCI

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 series Bidirectional Communication Interface BCI Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a...

7.5CVSS7.7AI score0.0095EPSS
SaveExploits0References4
ICS
ICS
•added 2021/12/02 12:00 a.m.•161 views

Hitachi Energy RTU500 series

1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 series Vulnerabilities: Observable Discrepancy, Buffer Over-read, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an...

8.6CVSS7.1AI score0.16986EPSS
SaveExploits0References5
OSV
OSV
•added 2021/11/26 5:15 p.m.•15 views

CVE-2021-35533

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface BCI IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted messag...

7.5CVSS7.1AI score0.0095EPSS
SaveExploits0References1
NVD
NVD
•added 2021/11/26 5:15 p.m.•30 views

CVE-2021-35533

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface BCI IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted messag...

7.5CVSS0.0095EPSS
SaveExploits0References1
Prion
Prion
•added 2021/11/26 5:15 p.m.•29 views

Input validation

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface BCI IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted messag...

7.1CVSS7.4AI score0.0095EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2021/11/26 4:37 p.m.•43 views

CVE-2021-35533 Specially Crafted IEC 60870-5-104 Packet Vulnerability in RTU500 series

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface BCI IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted messag...

7.5CVSS7.6AI score0.0095EPSS
SaveExploits0References1
CVE
CVE
•added 2021/11/26 4:37 p.m.•79 views

CVE-2021-35533

The CVE-2021-35533 affects Hitachi Energy RTU500 series CMU firmware 12.0.x, 12.2.x and 12.4.x, in the APDU parser of the BCI IEC 60870-5-104 function. A crafted BCI message can trigger a reboot of the RTU500 CMU when the BCI is enabled and configured. By default, the BCI function is disabled, re...

7.5CVSS7.4AI score0.0095EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/11/26 12:00 a.m.•2 views

CVE-2021-35533: Improper Input Validation

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface BCI IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted messag...

7.5CVSS5.9AI score0.0095EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2021/11/26 12:00 a.m.•22 views

Hitachi Energy Relion 输入验证错误漏洞

Hitachi Energy Relion is a power system for protection, control, measurement and monitoring from Hitachi Energy, Switzerland. A security vulnerability exists in the Hitachi Energy RTU500 series that stems from incorrect input validation in the APDU parser in the IEC 60870-5-104 function...

7.5CVSS7.3AI score0.0095EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2021/11/26 12:00 a.m.•25 views

PT-2021-20956 · Hitachi Energy · Rtu500 Series Cmu Firmware

Name of the Vulnerable Software and Affected Versions: Hitachi Energy RTU500 series CMU Firmware version 12.0. Hitachi Energy RTU500 series CMU Firmware version 12.2. Hitachi Energy RTU500 series CMU Firmware version 12.4. Description: The issue is related to an Improper Input Validation...

7.5CVSS7.3AI score0.0095EPSS
SaveExploits0References5
attackerkb
attackerkb
•added 2021/11/17 2:00 p.m.•11 views

CVE-2021-35533

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface BCI IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted messag...

7.5CVSS7.1AI score0.0095EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/06/14 12:00 a.m.•5 views

CVE-2021-27196: Improper Input Validation

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 TEGO1, MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce th...

7.5CVSS5.8AI score0.01575EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2021/06/14 12:00 a.m.•19 views

PT-2021-17315 · Hitachi Abb Power Grids · Msm +9

Name of the Vulnerable Software and Affected Versions: Hitachi ABB Power Grids Relion 670 Series versions 1.1 through 2.2.3 Hitachi ABB Power Grids Relion 670/650 Series version 2.2.0 Hitachi ABB Power Grids Relion 670/650/SAM600-IO version 2.2.1 Hitachi ABB Power Grids Relion 650 versions 1.1...

7.5CVSS7.3AI score0.01575EPSS
SaveExploits0References12
Rows per page