Lucene search
+L

6093 matches found

ATTACKERKB
ATTACKERKB
added 2026/06/03 4:56 p.m.10 views

CVE-2019-25720

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score0.00199EPSS
SaveExploits0References3
CVE
CVE
added 2026/06/03 4:56 p.m.29 views

CVE-2019-25720

This CVE affects Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). The vulnerability is a denial-of-service caused by processing a malformed network packet, allowing an unauthenticated attacker to reboot the monitor. Repeated malformed packets can disrupt patient ...

7.1CVSS5.8AI score0.00199EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/06/03 3:49 p.m.10 views

CVE-2026-46249

In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...

5.8AI score0.00115EPSS
SaveExploits0References9Affected Software1
EUVD
EUVD
added 2026/06/03 3:49 p.m.22 views

EUVD-2026-34111

In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...

5.8AI score0.00115EPSS
SaveExploits0References8
OSV
OSV
added 2026/06/03 3:49 p.m.13 views

CVE-2026-46249 octeontx2-af: Fix PF driver crash with kexec kernel booting

In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...

5.9AI score
SaveExploits0References11
CVE
CVE
added 2026/06/03 3:49 p.m.45 views

CVE-2026-46249

The CVE-2026-46249 issue affects the Linux kernel octeontx2-af PF driver. During a kexec reboot, the old AF state may persist if the PF driver probes before AF reinitializes, and if the RVUM block revision is not cleared on shutdown, PF can mis-detect AF readiness and access stale hardware, leadi...

5.5CVSS5.8AI score0.00115EPSS
SaveExploits0References8Affected Software1
EUVD
EUVD
added 2026/06/03 12:30 a.m.22 views

EUVD-2022-55996

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.0016EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2026/06/03 12:00 a.m.18 views

Linux kernel 安全漏洞

The Linux kernel is the core of the open-source operating system Linux, developed by the Linux Foundation in the United States. There is a security vulnerability in the Linux kernel, which stems from the octeontx2-af driver failing to clear the RVUM block revision during kexec reboot. This causes...

5.5CVSS5.3AI score0.00115EPSS
SaveExploits0References8
Tenable Nessus
Tenable Nessus
added 2026/06/03 12:00 a.m.15 views

Linux Distros Unpatched Vulnerability : CVE-2026-46249

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist...

5.5CVSS5.9AI score0.00115EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2026/06/03 12:00 a.m.23 views

PT-2026-45983

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score0.00199EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2026/06/02 9:06 p.m.49 views

CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.0016EPSS
SaveExploits0References2
CVE
CVE
added 2026/06/02 9:06 p.m.42 views

CVE-2022-4992

CVE-2022-4992 affects Dräger Infinity Acute Care System and Standalone Infinity M540, VG4.1.1, VG4.0.3 and lower (VG4.2 partially affected). The issue is a network message handling vulnerability that lets remote attackers inject spoofed/tampered data to cause denial-of-service, potentially modify...

8.8CVSS5.8AI score0.0016EPSS
SaveExploits0References2
NVD
NVD
added 2026/06/02 8:16 p.m.30 views

CVE-2019-25721

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.00187EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2026/06/02 7:11 p.m.12 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2026/06/02 7:11 p.m.52 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS0.00175EPSS
SaveExploits0References2
EUVD
EUVD
added 2026/06/02 7:11 p.m.27 views

EUVD-2019-20160

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/06/02 6:44 p.m.11 views

CVE-2019-25722

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...

7.6CVSS5.9AI score0.00193EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
added 2026/06/02 6:44 p.m.12 views

CVE-2019-25722 Dräger SC Monitoring Devices Hard-coded Credentials and DoS

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...

7.6CVSS5.9AI score0.00193EPSS
SaveExploits0References2
CVE
CVE
added 2026/06/02 6:44 p.m.39 views

CVE-2019-25722

The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...

7.6CVSS5.9AI score0.00193EPSS
SaveExploits0References2
NVD
NVD
added 2026/06/02 5:16 p.m.23 views

CVE-2026-1871

TP-Link Tapo C200 v5 contains a stack-based buffer overflow flaw in RTSP authentication handling due to improper validation of Authorization header field lengths, which can be triggered by a crafted authentication request. Successful exploitation causes the affected RTSP core service process to...

7.1CVSS0.00305EPSS
SaveExploits0References4
Rows per page
Query Builder