Lucene search
K

5650 matches found

RedhatCVE
RedhatCVE
added yesterday1 views

CVE-2026-46249

A flaw was found in the Linux kernel's octeontx2-af PF driver. This vulnerability occurs during a kexec reboot when the hardware is not power-cycled, causing the AF state from the old kernel to persist. If the RVUM block revision is not cleared during AF shutdown, the PF driver may incorrectly...

5.5CVSS5.8AI score
Exploits0References4
NVD
NVD
added yesterday2 views

CVE-2019-25720

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS
Exploits0References2
Vulnrichment
Vulnrichment
added yesterday2 views

CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score
Exploits0References2
ATTACKERKB
ATTACKERKB
added yesterday1 views

CVE-2019-25720

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score
Exploits0References3
CVE
CVE
added yesterday4 views

CVE-2019-25720

This CVE affects Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). The vulnerability is a denial-of-service caused by processing a malformed network packet, allowing an unauthenticated attacker to reboot the monitor. Repeated malformed packets can disrupt patient ...

7.1CVSS5.8AI score
Exploits0References2
Cvelist
Cvelist
added yesterday4 views

CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS
Exploits0References2
CVE
CVE
added yesterday1 views

CVE-2026-46249

CVE-2026-46249 (octeontx2-af) describes a fault in the Linux kernel where, during a kexec reboot, the AF state from the old kernel may persist and be misinterpreted by the PF driver if both drivers are built as modules. The PF driver can probe before AF reinitializes hardware; it uses the RVUM bl...

5.8AI score
Exploits0References8
EUVD
EUVD
added yesterday2 views

EUVD-2026-34111

In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...

5.8AI score
Exploits0References8
ATTACKERKB
ATTACKERKB
added yesterday1 views

CVE-2026-46249

In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...

5.8AI score
Exploits0References9Affected Software1
EUVD
EUVD
added yesterday5 views

EUVD-2022-55996

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References3
Positive Technologies
Positive Technologies
added yesterday2 views

PT-2026-46012

In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...

5.8AI score
Exploits0References9
Positive Technologies
Positive Technologies
added yesterday2 views

PT-2026-45983

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...

7.1CVSS5.8AI score
Exploits0References3
CVE
CVE
added 2 days ago8 views

CVE-2022-4992

CVE-2022-4992 affects Dräger Infinity Acute Care System and Standalone Infinity M540, VG4.1.1, VG4.0.3 and lower (VG4.2 partially affected). The issue is a network message handling vulnerability that lets remote attackers inject spoofed/tampered data to cause denial-of-service, potentially modify...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References2
Cvelist
Cvelist
added 2 days ago23 views

CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.00045EPSS
Exploits0References2
NVD
NVD
added 2 days ago1 views

CVE-2019-25721

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.00016EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 2 days ago2 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
EUVD
EUVD
added 2 days ago3 views

EUVD-2019-20160

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
Cvelist
Cvelist
added 2 days ago23 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS0.00016EPSS
Exploits0References2
CVE
CVE
added 2 days ago5 views

CVE-2019-25722

The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...

7.6CVSS5.9AI score0.00043EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2 days ago3 views

CVE-2019-25722

Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...

7.6CVSS5.9AI score0.00043EPSS
Exploits0References4
Rows per page