503 matches found
CVE-2021-42705
PLC Editor Versions 1.3.8 and prior is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code...
CVE-2021-34593
In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing...
FATEK Automation WinProladder 缓冲区错误漏洞
FATEK Automation WinProladder is a PLC from FATEK Automation in China.An out-of-bounds read vulnerability exists in FATEK Automation WinProladder, which can be exploited by attackers to read unauthorized information...
The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Expert, allows a intruder to trigger a service failure.
The vulnerability of the programming software for PLCs programmable logic controllers, EcoStruxure Control Expert, lies in the copying of buffers without checking the size of the input data. Exploiting this vulnerability could allow a malicious actor to cause malfunctions in the system remotely...
The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the absence of authentication for a critical function, allowing attackers to execute arbitrary commands.
The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium lies in the absence of authentication for critical functions. Exploiting this vulnerability allows an attacker operating remotely to...
WAGO 安全漏洞
WAGO is a 750-88x series programmable logic controller from WAGO, Germany. This device is designed for applications in industrial environments where digital algorithms operate electronic systems. A security vulnerability in the OpenSSL implementation of the WAGO 750-831/xxx xxx, 750-880/xxx xxx,...
WAGO 授权问题漏洞
WAGO is a 750-88x series programmable logic controller from WAGO, Germany. The device is specifically designed for use in industrial environments as an electronic system for the operation of digital algorithms. An authorization issue exists in WAGO PLC in firmware version FW07, which can be...
The vulnerability of Schneider Electric’s Modbus Serial Driver for programmable logic controllers is related to errors in processing hypertext links, allowing an attacker to re-write files in the file system.
The vulnerability of Schneider Electric’s Modbus Serial Driver relates to errors in processing hypertext links. Exploiting this vulnerability could allow an attacker to re-record files in the file system...
The vulnerability of the Modbus protocol implementation in microprogrammed software for programmable logic controllers like Modicon Quantum arises from incorrect code generation. This allows attackers to trigger malfunctions during maintenance operations.
The vulnerability of the Modbus protocol implementation in microprogrammed software for programmable logic controllers like Modicon Quantum is related to incorrect code generation. Exploiting this vulnerability could allow an attacker, operating remotely, to cause malfunctions in the system’s...
The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Expert, allows a intruder to trigger a service failure.
The vulnerability of the EcoStruxure Control Expert programming tool for programmable logic controllers is related to insufficient checking of unusual or exceptional states. Exploiting this vulnerability could allow a malicious actor to trigger a service failure remotely...
The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Expert, allows a intruder to bypass the authentication process.
The vulnerability of the programming software for PLCs programmable logic controllers, EcoStruxure Control Expert, is related to improper authentication. Exploiting this vulnerability can allow an attacker to bypass authentication processes...
The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Expert, allows a intruder to bypass the authentication process.
The vulnerability of the programming software for PLCs programmable logic controllers, EcoStruxure Control Expert, lies in the absence of restrictions on the number of authentication attempts. Exploiting this vulnerability allows a malicious actor to bypass the authentication process remotely...
MAC1100 PLC 信息泄露漏洞
The MAC1100 PLC is an industrial control product PLC. An information disclosure vulnerability exists in the EPA protocol of the MAC1100 PLC, which could allow an attacker to read a specific storage area and collect relevant device information in the PLC via an unauthorized EPA read operation, whi...
MAC1100 PLC 安全漏洞
The MAC1100 PLC is an industrial control product PLC. A security vulnerability exists in the MAC1100 PLC that can be exploited by an attacker to gain access to the system and escalate privileges via a crafted package...
Siemens SIMATIC S7-1500 CPU和SIMATIC S7-1500 授权问题漏洞
The Siemens SIMATIC S7-1500 CPU and SIMATIC S7-1500 are both products of Siemens, Germany.The SIMATIC S7-1500 CPU is a CPU central processing unit module.The SIMATIC S7-1500 is a programmable logic controller. A security vulnerability exists in the Siemens SIMATIC S7-1500 CPU and SIMATIC S7-1500...
The vulnerability of DIAScreen software for programmable logic controllers arises from buffer overflows in dynamic memory, allowing an attacker to execute arbitrary code.
The vulnerability of the software for programmable logic controllers DIAScreen arises from buffer overflow in dynamic memory. Exploiting this vulnerability allows a remote attacker to execute arbitrary code write-off memory boundaries...
isf
This is an Industrial Exploitation Framework ISF repository, a Python-based framework for exploitation and testing of industrial control systems ICS. The framework is similar to Metasploit and is designed to be used for penetration testing and vulnerability assessment of ICS devices. The reposito...
CLICK PLC CPU Modules 授权问题漏洞
CLICK PLC CPU Modules are Automation Direct's network devicesA single CLICK CPU Module can be connected to up to eight I/O modules to expand the number of system I/O and meet the needs of a specific application. An authorization issue vulnerability exists in Automation Direct CLICK PLC CPU Module...
CLICK PLC CPU Modules 授权问题漏洞
CLICK PLC CPU Modules are Automation Direct's network devices A single CLICK CPU Module can be connected to up to 8 I/O modules to expand the amount of system I/O and meet the needs of a specific application. A security vulnerability exists in Automation Direct CLICK PLC CPU Modules that results ...