Lucene search
+L

502 matches found

ATTACKERKB
ATTACKERKB
added 2026/04/09 10:52 a.m.7 views

CVE-2024-1490

An authenticated remote attacker with high privileges can exploit the OpenVPN configuration via the web-based management interface of a WAGO PLC. If user-defined scripts are permitted, OpenVPN may allow the execution of arbitrary shell commands enabling the attacker to run arbitrary commands on t...

7.2CVSS6.2AI score0.00729EPSS
SaveExploits0References3
ICS
ICS
added 2026/04/09 6:0 a.m.13 views

Contemporary Controls BASC 20T

RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to enumerate the functionality of each component associated with the PLC, reconfigure, rename, delete, perform file transfers, and make remote procedure calls. 2. RECOMMENDED PRACTICES CISA recommends users...

9.8CVSS6AI score0.00443EPSS
SaveExploits0References13
RedhatCVE
RedhatCVE
added 2026/03/26 3:4 p.m.10 views

CVE-2025-40943

Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering an authorized user, who has the function right "Read diagnostics", to import a specially crafted trace file. The malicious trace file is insufficiently sanitiz...

9.6CVSS6.1AI score0.00458EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2026/03/20 11:19 p.m.8 views

CVE-2026-24060

Service information is not encrypted when transmitted as BACnet packets over the wire, and can be sniffed, intercepted, and modified by an attacker. Valuable information such as the File Start Position and File Data can be sniffed from network traffic using Wireshark's BACnet dissector filter. Th...

9.1CVSS5.8AI score0.002EPSS
SaveExploits1References4
CNNVD
CNNVD
added 2026/03/03 12:0 a.m.20 views

Mitsubishi Electric MELSEC iQ-F series 安全漏洞

The Mitsubishi Electric MELSEC iQ-F series is a programmable logic controller developed by Mitsubishi Electric, a Japanese company. The MELSEC iQ-F series contains security vulnerabilities, which stem from improper resource closure or release procedures. This could allow remote attackers to cause...

8.7CVSS5.8AI score0.00426EPSS
SaveExploits0References3
RedhatCVE
RedhatCVE
added 2026/02/21 7:29 p.m.9 views

CVE-2026-24790

The underlying PLC of the device can be remotely influenced, without proper safeguards or authentication...

8.2CVSS5.4AI score0.00449EPSS
SaveExploits0References1
NVD
NVD
added 2026/02/20 5:25 p.m.11 views

CVE-2026-24790

The underlying PLC of the device can be remotely influenced, without proper safeguards or authentication...

8.2CVSS0.00449EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2026/02/20 4:15 p.m.30 views

CVE-2026-24790 Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller Missing Authentication for Critical Function

The underlying PLC of the device can be remotely influenced, without proper safeguards or authentication...

8.2CVSS0.00449EPSS
SaveExploits0References3
CVE
CVE
added 2026/02/20 4:15 p.m.24 views

CVE-2026-24790

Technical details about CVE-2026-24790 are not publicly available in the provided documents. Monitor for updates.

8.2CVSS5.4AI score0.00449EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2026/02/20 12:0 a.m.8 views

PT-2026-21251

The underlying PLC of the device can be remotely influenced, without proper safeguards or authentication...

8.2CVSS5.4AI score0.00449EPSS
SaveExploits0References4
CNNVD
CNNVD
added 2026/02/20 12:0 a.m.15 views

Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller 访问控制错误漏洞

The Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller is an industrial natural gas odorization system developed by the American company Welker. This system has a security vulnerability known as access control errors. The vulnerability stems from insufficient protective measures or...

8.2CVSS5.9AI score0.00449EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2026/01/22 10:21 p.m.29 views

CVE-2025-25051 AutomationDirect CLICK Programmable Logic Controller Plaintext Storage of a Password

An attacker could decrypt sensitive data, impersonate legitimate users or devices, and potentially gain access to network resources for lateral attacks...

6.1CVSS0.00099EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2026/01/22 10:17 p.m.7 views

CVE-2025-67652 AutomationDirect CLICK Programmable Logic Controller Weak Encoding for Password

An attacker with access to the project file could use the exposed credentials to impersonate users, escalate privileges, or gain unauthorized access to systems and services. The absence of robust encryption or secure handling mechanisms increases the likelihood of this type of exploitation, leavi...

6.1CVSS5.5AI score0.00101EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2026/01/22 12:0 a.m.17 views

AutomationDirect CLICK Programmable Logic Controller security vulnerability

The AutomationDirect CLICK Programmable Logic Controller is a programmable logic controller developed by the AutomationDirect company in the United States. The AutomationDirect CLICK Programmable Logic Controller has a security vulnerability. This vulnerability allows attackers to decrypt sensiti...

6.1CVSS5.8AI score0.00099EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2026/01/22 12:0 a.m.17 views

AutomationDirect CLICK Programmable Logic Controller security vulnerability

The AutomationDirect CLICK Programmable Logic Controller is a programmable logic controller developed by the AutomationDirect company in the United States. The AutomationDirect CLICK Programmable Logic Controller has a security vulnerability. This vulnerability stems from the exposure of...

6.1CVSS5.8AI score0.00101EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2025/12/30 12:0 a.m.13 views

PT-2025-53856

Name of the Vulnerable Software and Affected Versions DVP-12SE11T affected versions not specified Description Password protection on the DVP-12SE11T Programmable Logic Controller PLC can be bypassed remotely without authentication. This allows unauthorized access and potential manipulation of the...

9.8CVSS6.4AI score0.00277EPSS
SaveExploits0References10
NVD
NVD
added 2025/12/13 1:15 a.m.17 views

CVE-2025-13970

OpenPLCV3 is vulnerable to a cross-site request forgery CSRF attack due to the absence of proper CSRF validation. This issue allows an unauthenticated attacker to trick a logged-in administrator into visiting a maliciously crafted link, potentially enabling unauthorized modification of PLC settin...

8CVSS0.00284EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2025/12/13 12:0 a.m.21 views

PT-2025-51034

Name of the Vulnerable Software and Affected Versions OpenPLC V3 affected versions not specified Description The software is susceptible to a cross-site request forgery CSRF attack because of missing CSRF validation. An unauthenticated attacker can potentially trick a logged-in administrator into...

8CVSS6.5AI score0.00284EPSS
SaveExploits0References9
EUVD
EUVD
added 2025/12/02 3:30 p.m.10 views

EUVD-2025-200231

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf'. The 'GetParametermeter' function retrieves the user input, which is directly incorporated...

8.5CVSS6.7AI score0.00364EPSS
SaveExploits0References2
EUVD
EUVD
added 2025/12/02 3:30 p.m.10 views

EUVD-2025-200227

Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'DownloadFile' function converts a parameter to an integer using 'atoi' and then uses it as an index in the 'FilesDownload' array with '&FilesDownloadiVar2'. If the parameter is too large, it will access memory beyond...

7.1CVSS6.3AI score0.00257EPSS
SaveExploits0References2
Rows per page
Query Builder