Lucene search
+L

530 matches found

Positive Technologies
Positive Technologies
•added 2024/09/13 12:00 a.m.•38 views

PT-2024-30295 · Automationdirect · Directlogic H2-Dm1E +1

Name of the Vulnerable Software and Affected Versions: No specific software or versions are mentioned in the provided descriptions. Description: The issue concerns a session hijacking attack targeting the application layer's control mechanism. This mechanism manages authenticated sessions between...

8.8CVSS6.8AI score0.00284EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2024/09/10 12:00 a.m.•27 views

PT-2024-37920 · Unknown · Oscat Basic Library

Name of the Vulnerable Software and Affected Versions: OSCAT Basic Library affected versions not specified Description: The issue is an Out-of-Bounds read vulnerability that allows a local, unprivileged attacker to access limited internal data of the PLC, which may lead to a crash of the affected...

4.4CVSS6.7AI score0.00189EPSS
SaveExploits0References6
CNNVD
CNNVD
•added 2024/09/10 12:00 a.m.•21 views

CODESYS OSCAT Basic Library 缓冲区错误漏洞

CODESYS OSCAT Basic Library is an open source library from CODESYS Corporation, known as the Open Source Community for Automation Technology. A buffer error vulnerability exists in CODESYS OSCAT Basic Library versions prior to 3.3.5, which stems from the presence of an out-of-bounds read...

4.4CVSS6.6AI score0.00189EPSS
SaveExploits0References3
osv_cve
osv_cve
•added 2024/09/04 1:15 a.m.•21 views

CVE-2024-41716

Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product's project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate...

8.1CVSS5.8AI score0.00447EPSS
SaveExploits0References2
Japan Vulnerability Notes
Japan Vulnerability Notes
•added 2024/08/29 6:08 a.m.•28 views

WindLDR and WindO/I-NV4 store sensitive information in cleartext

Overview PLC programming software "WindLDR" and Operator Interfaces' Touchscreen Programming Software "WindO/I-NV4" provided by IDEC Corporation store sensitive information in cleartext form CWE-312. Yuki Meguro of Toinx Co., Ltd. reported this vulnerability to IPA. JPCERT/CC coordinated with the...

8.1CVSS6.6AI score0.00447EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
•added 2024/07/31 12:00 a.m.•22 views

Unitronics Vision PLC Logic Exception Malfunction

The vulnerability of microprogrammed logic controllers from Unitronics Vision PLC lies in the improper handling of exceptional states. Exploiting this vulnerability can allow an attacker to cause malfunctions in the system remotely...

6.8CVSS5.4AI score0.00447EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
•added 2024/07/23 12:00 a.m.•27 views

ControlLogix PLC Input Validation

The vulnerability of microprogrammed software in programmable logic controllers such as ControlLogix 5580, GuardLogix 5580, CompactLogix 5380, CompactLogix 5480, Compact GuardLogix 5380, and 1756-EN4TR is related to insufficient validation of input data. Exploiting this vulnerability can allow an...

8.6CVSS5.5AI score0.00637EPSS
SaveExploits0References5Affected Software6
BDU FSTEC
BDU FSTEC
•added 2024/07/23 12:00 a.m.•18 views

Siemens LOGO PLC Access Control

The vulnerability of the access control mechanism in Siemens LOGO programmable logic controllers is related to the absence of authentication for critical functions. Exploiting this vulnerability allows a remote attacker to execute arbitrary commands...

8.8CVSS5.9AI score
SaveExploits0Affected Software1
CNVD
CNVD
•added 2024/06/12 12:00 a.m.•23 views

Siemens S7-200 SMART series uses unsafe random value vulnerability

The S7-200 SMART series is a series of miniature programmable logic controllers that control a variety of small automation applications. A use of insecure random values vulnerability exists in the Siemens S7-200 SMART series, which can be exploited by an attacker to create a denial of service...

8.8CVSS6.6AI score0.00387EPSS
SaveExploits0References1
ICS
ICS
•added 2024/06/11 12:00 a.m.•42 views

Siemens SIMATIC S7-200 SMART Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

8.8CVSS8.2AI score0.00387EPSS
SaveExploits0References12
BDU FSTEC
BDU FSTEC
•added 2024/06/03 12:00 a.m.•22 views

AutomationDirect P3-550E DoS

The vulnerability of the application software interface for Microprogramming Systems, AutomationDirect P3-550E, is related to writing beyond the buffer boundaries in memory. Exploiting this vulnerability could allow an attacker to cause a service failure...

8.5CVSS5.7AI score0.00489EPSS
SaveExploits1References6Affected Software6
BDU FSTEC
BDU FSTEC
•added 2024/05/31 12:00 a.m.•20 views

AutomationDirect P3-550E DoS

The vulnerability of the application software interface for Microprogramming Systems, AutomationDirect P3-550E, is related to writing beyond the buffer boundaries in memory. Exploiting this vulnerability could allow an attacker to cause a service failure...

8.5CVSS5.7AI score0.00542EPSS
SaveExploits1References6Affected Software6
BDU FSTEC
BDU FSTEC
•added 2024/05/31 12:00 a.m.•21 views

AutomationDirect P3-550E DoS

The vulnerability of the application software interface for Microprogramming Systems, AutomationDirect P3-550E, is related to writing beyond the buffer boundaries in memory. Exploiting this vulnerability could allow an attacker to cause a service failure...

8.5CVSS5.7AI score0.00489EPSS
SaveExploits1References6Affected Software6
BDU FSTEC
BDU FSTEC
•added 2024/05/31 12:00 a.m.•18 views

CurrDir Component DoS

The vulnerability of the CurrDir component in the AutomationDirect P3-550E programmable logic controllers is related to writing beyond the buffer boundaries in memory. Exploiting this vulnerability could allow an attacker to cause a service failure remotely...

8.5CVSS5.6AI score0.00836EPSS
SaveExploits1References6Affected Software6
Microsoft Secure
Microsoft Secure
•added 2024/05/30 5:00 p.m.•89 views

Exposed and vulnerable: Recent attacks highlight critical need to protect internet-exposed OT devices

Since late 2023, Microsoft has observed an increase in reports of attacks focusing on internet-exposed, poorly secured operational technology OT devices. Internet-exposed OT equipment in water and wastewater systems WWS in the US were targeted in multiple attacks over the past months by different...

9.8CVSS7.2AI score0.02089EPSS
SaveExploits0
BDU FSTEC
BDU FSTEC
•added 2024/05/08 12:00 a.m.•16 views

Yokogawa FA-M3 FTP DoS

The vulnerability of the FTP server software of the Yokogawa FA-M3 programmable logic controller is related to the exhaustion of the connection limits. Exploiting this vulnerability can allow a malicious actor to cause service failures remotely...

5.3CVSS5.5AI score
SaveExploits0
CNNVD
CNNVD
•added 2024/04/09 12:00 a.m.•22 views

Siemens SCALANCE W700产品系列安全漏洞

Siemens SCALANCE is a series of Ethernet switches from Siemens, Germany. It connects to Industrial Control System ICS devices, including Programmable Logic Controllers PLCs and Human Machine Interface HMI systems. A security vulnerability exists in the Siemens SCALANCE W700 product family, which...

8.4CVSS6.6AI score0.00234EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2024/04/09 12:00 a.m.•17 views

Siemens SCALANCE W700产品系列安全漏洞

Siemens SCALANCE is a series of Ethernet switches from Siemens, Germany. It connects to industrial control system ICS devices, including programmable logic controllers PLCs and human machine interface HMI systems. A security vulnerability exists in the Siemens SCALANCE W700 product family that...

6.1CVSS6.7AI score0.00214EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2024/03/22 12:00 a.m.•21 views

UniLogic Studio Authentication Bypass

The vulnerability of the microprogramming software for UniLogic Studio series UniStream is related to deficiencies in authentication procedures. Exploiting this vulnerability could allow an attacker to circumvent security restrictions remotely...

10CVSS5.4AI score0.00684EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
•added 2024/03/22 12:00 a.m.•21 views

UniLogic Studio UniStream Path Traversal

The vulnerability of the microprogramming software for UniLogic Studio programmable logic controllers of the UniStream series is related to an incorrect limitation on the path name of the restricted access directory. Exploiting this vulnerability could allow a malicious actor to execute arbitrary...

10CVSS5.9AI score0.00854EPSS
SaveExploits0References4Affected Software1
Rows per page
Query Builder