36 matches found
CVE-2017-12741
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually...
EUVD-2005-0290
Malware in sbrugna...
EUVD-2017-4280
Malware in sbrugna...
CVE-2012-4703
The Emerson DeltaV SE3006 through 11.3.1, DeltaV VE3005 through 10.3.1 and 11.x through 11.3.1, and DeltaV VE3006 through 10.3.1 and 11.x through 11.3.1 allow remote attackers to cause a denial of service device restart via a crafted packet on 1 TCP port 23, 2 UDP port 161, or 3 TCP port 513...
Cisco IOS XE SNMP OID Handling Out-Of-Bounds Read Denial-of-Service Vulnerability
This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Cisco IOS XE. Authentication is required to exploit this vulnerability. The specific flaw exists within the SNMP service, which listens on UDP port 161 by default. The issue results fro...
Cisco IOS XE SNMP SET cewEventTime Stack-based Buffer Overflow Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Cisco IOS XE. Authentication is required to exploit this vulnerability. The specific flaw exists within the SNMP service, which listens on UDP port 161 by default. The issue results from the lack of...
Schneider Electric Modicon Ethernet Serial RTU Improper Check For Unusual or Exceptional Conditions (CVE-2019-6831)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on por...
CVE-2019-19276
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI KTP Mobile Panels All versions V16 Update 4. Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manu...
多款 Siemens 设备缓冲区错误漏洞
Siemens SIMATIC is a configuration software from Siemens. A denial of service vulnerability exists in multiple Siemens products. The vulnerability originates from specially crafted packets sent to port 161/UDP and can be exploited by an attacker to cause the SNMP service on the affected device to...
Siemens SNMP Implementation of WinCC Runtime
1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SNMP Implementation of WinCC Runtime Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could crash the SNMP service and require a...
Schneider Electric Modicon Ethernet Serial RTU
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Schneider Electric Equipment: Modicon BMXNOR0200H Vulnerabilities: Improper Check for Unusual or Exceptional Conditions, Improper Access Control 2. RISK EVALUATION Successful exploitation of these...
Siemens Industrial Products SNMP (Update F)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2019-6813
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions and Modicon M340 controller all firmware versions, which could cause denial of service when truncated SNMP packets on port 161/UDP are received by...
Design/Logic Flaw
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions and Modicon M340 controller all firmware versions, which could cause denial of service when truncated SNMP packets on port 161/UDP are received by...
CVE-2019-6813
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions and Modicon M340 controller all firmware versions, which could cause denial of service when truncated SNMP packets on port 161/UDP are received by...
The vulnerability of microprogrammed software in programmable logic controllers from SIMATIC, related to insufficient validation of input data, allows a malicious actor to trigger malfunctions during maintenance operations.
The vulnerability of microprogrammed software in programmable logic controllers from SIMATIC is related to insufficient verification of input data. Exploiting this vulnerability can allow a malicious individual to cause malfunctions in service operations by sending specially crafted packets to po...
Siemens SIMOCODE pro V EIP
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMOCODE pro V EIP Vulnerability : Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service condition...
CVE-2017-12741
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually...
CVE-2017-12741
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually...
Design/Logic Flaw
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M...