Lucene search

K
nessusThis script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SCHNEIDER_CVE-2019-6831.NASL
HistoryJun 29, 2023 - 12:00 a.m.

Schneider Electric Modicon Ethernet Serial RTU Improper Check For Unusual or Exceptional Conditions (CVE-2019-6831)

2023-06-2900:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
3
schneider electric
modiconm340m580cp
cwe-754
vulnerability
iec 60870- 5-104
network segmentation
firewall
snmp port 161/udp
port 2404/tcp

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:N/I:N/A:P

8.6 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

8.7 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

50.6%

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501214);
  script_version("1.5");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/03/04");

  script_cve_id("CVE-2019-6831");

  script_name(english:"Schneider Electric Modicon Ethernet Serial RTU Improper Check For Unusual or Exceptional Conditions (CVE-2019-6831)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A CWE-754: Improper Check for Unusual or Exceptional Conditions
vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all
firmware versions), which could cause disconnection of active
connections when an unusually high number of IEC 60870- 5-104 packets
are received by the module on port 2404/TCP.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://security.cse.iitk.ac.in/responsible-disclosure");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-20-044-01");
  # https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-225-03
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?d9d1e4db");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Schneider Electric recommends users set up network segmentation and implement a firewall to block all unauthorized
access to Port 2404/TCP and SNMP Port 161/UDP.

For more information, see the Schneider Electric security notification.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-6831");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(754);

  script_set_attribute(attribute:"vuln_publication_date", value:"2019/09/17");
  script_set_attribute(attribute:"patch_publication_date", value:"2019/09/17");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/06/29");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:bmxnor0200h_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:bmxnor0200h_firmware" :
        {"family" : "ModiconM340M580CP"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
schneider-electricbmxnor0200h_firmwarecpe:/o:schneider-electric:bmxnor0200h_firmware

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:N/I:N/A:P

8.6 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

8.7 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

50.6%

Related for TENABLE_OT_SCHNEIDER_CVE-2019-6831.NASL