322 matches found
EUVD-2022-52791
Malicious code in bioql PyPI...
EUVD-2021-8239
Malicious code in bioql PyPI...
EUVD-2022-52790
Malicious code in bioql PyPI...
EUVD-2024-39278
Malicious code in bioql PyPI...
EUVD-2022-52788
Malicious code in bioql PyPI...
EUVD-2021-8238
Malicious code in bioql PyPI...
EUVD-2022-34265
Malicious code in bioql PyPI...
CVE-2024-41927
Cleartext transmission of sensitive information vulnerability exists in multiple IDEC PLCs. If an attacker sends a specific command to PLC's serial communication port, user credentials may be obtained. As a result, the program of the PLC may be obtained, and the PLC may be manipulated...
CVE-2023-46143
Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC...
CVE-2022-29951
JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol configurable on ports 1024-65534 on either TCP or UDP for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing...
CVE-2022-31204
Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations such as project/logic uploads and downloads. This...
CVE-2020-7498
A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software all versions. The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file...
CVE-2019-6843
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware version prior to V3.10, Modicon M340 all firmware versions, and Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the PLC when upgrading...
Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety PLCs Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2023-6408)
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. This plugin only works with Tenable.ot...
Phoenix Contact ILC PLCs Improper Authentication (CVE-2016-8371)
The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Phoenix Contact ILC PLCs Improper Authentication (CVE-2016-8380)
The web server in Phoenix Contact ILC PLCs allows access to read and write PLC variables without authentication. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...
Phoenix Contact ILC PLCs Denial of Service (CVE-2021-33541)
Phoenix Contact Classic Line Controllers ILC1x0 and ILC1x1 in all versions/variants are affected by a Denial-of-Service vulnerability. The communication protocols and device access do not feature authentication measures. Remote attackers can use specially crafted IP packets to cause a denial of...
Phoenix Contact ILC PLCs Cleartext Storage of Sensitive Information (CVE-2016-8366)
Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text. This plugin only works with...
Researchers Uncover Major Security Vulnerabilities in Industrial MMS Protocol Libraries
Details have emerged about multiple security vulnerabilities in two implementations of the Manufacturing Message Specification MMS protocol that, if successfully exploited, could have severe impacts in industrial environments. "The vulnerabilities could allow an attacker to crash an industrial...
IDEC Products (Update A)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION : Low Attack Complexity Vendor : IDEC Corporation Equipment : IDEC PLCs Vulnerabilities : Cleartext Transmission of Sensitive Information, Generation of Predictable Identifiers 2. RISK EVALUATION Successful exploitation of these vulnerabilities...