3404 matches found
CVE-2012-0930
Cross-site scripting XSS vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...
CVE-2012-0931
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors...
Cross site scripting
Cross-site scripting XSS vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...
Authentication flaw
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors...
CVE-2012-0931
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors...
CVE-2012-0931
CVE-2012-0931 concerns Schneider Electric Modicon Quantum PLC. The issue is an authentication gap between the Unity software and the PLC, allowing remote attackers to cause a denial of service or potentially execute arbitrary code via unspecified vectors. Several connected sources (NVD, Tenable O...
CVE-2012-0930
The CVE-2012-0930 entry concerns the Schneider Electric Modicon Quantum PLC. All connected sources describe a Cross-Site Scripting (XSS) vulnerability in the Quantum PLC’s web context, enabling remote attackers to inject arbitrary web script or HTML via unspecified vectors. The affected component...
CVE-2012-0929
Schneider Electric Modicon Quantum PLC is affected by CVE-2012-0929 due to multiple buffer overflows in the PLC’s FTP and HTTP servers. Remote attackers can trigger a denial of service by sending malformed requests to either service. The publicly available details show the impact as DoS with netw...
CVE-2012-0930
Cross-site scripting XSS vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...
CVE-2012-0929: Improper Restriction of Operations within the Bounds of a Memory Buffer
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the 1 FTP server or 2 HTTP server...
CVE-2012-0930: Improper Neutralization of Input During Web Page Generation
Cross-site scripting XSS vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...
CVE-2012-0931: Improper Authentication
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors...
PT-2012-1184
Name of the Vulnerable Software and Affected Versions Schneider Electric Modicon Quantum PLC affected versions not specified Schneider Electric Modicon M340 affected versions not specified Description The issue is related to a lack of authentication between the Unity software and the PLC, which c...
PT-2012-1183
Name of the Vulnerable Software and Affected Versions Schneider Electric Modicon M340 affected versions not specified Schneider Electric Modicon Quantum PLC affected versions not specified Description The issue is related to insufficient input validation in the software of the programmable logic...
PT-2012-1182
Name of the Vulnerable Software and Affected Versions Schneider Electric Modicon Quantum PLC affected versions not specified Schneider Electric Modicon M340 affected versions not specified Description The issue is caused by multiple buffer overflows in the PLC's software, allowing remote attacker...
Ladder logic
The devices tested by the Basecamp Project included the D20 PLC by GE, The Modicon Quantum by Schneider Electric, Rockwell and Koyo Electronics. Each device was tested using a number of additional attack vectors. Researchers attempted to upload custom firmware or so-called “ladder logic” for the...
(Not) making the grade
The researchers working on Project Basecamp found significant security issues with programmable logic controller PLC they tested. Some PLCs were too brittle and insecure to even tolerate security scans and probing. The D20 ME PLC by General Electric – a widely deployed industrial system – fared t...
Security audits
A presentation on Project Basecamp was a highlight of the conference. The talk presented the findings of a volunteer-led security audit of leading programmable logic controllers PLCs. The audit found that decrepit hardware, buggy software and pitiful or nonexistent security features make thousand...
UPDATE: Looking For a 'FireSheep' Moment, Researchers Lay Bare Woeful SCADA Security
Miami, Florida – A no-holds barred presentation at the S4 Conference laid bare the woeful state of security for many industrial control systems that power the world’s critical infrastructure. Organizers have also cooperated with security scanning firms Rapid7 and Tenable to release modules for th...
Koyo DirectLogic PLC Password Brute Force Utility
This module attempts to authenticate to a locked Koyo DirectLogic PLC. The PLC uses a restrictive passcode, which can be A0000000 through A9999999. The "A" prefix can also be changed by the administrator to any other character, which can be set through the PREFIX option of this module. This modul...