Lucene search
+L

3404 matches found

exploitpack
exploitpack
•added 2012/07/14 12:00 a.m.•39 views

Siemens Simatic S7-300400 - CPU STARTSTOP Module (Metasploit)

Siemens Simatic S7-300400 - CPU STARTSTOP Module Metasploit Exploit Title: Siemens Simatic S7 300/400 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-300 PLC CVE : None require 'msf/core' class Metasploit3...

7.4AI score
SaveExploits0
Exploit DB
Exploit DB
•added 2012/07/14 12:00 a.m.•102 views

Siemens Simatic S7-300/400 - CPU START/STOP Module (Metasploit)

Exploit Title: Siemens Simatic S7 300/400 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-300 PLC CVE : None require 'msf/core' class Metasploit3 'Siemens Simatic S7-300/400 CPU START/STOP Module',...

5.3AI score
SaveExploits0
Exploit DB
Exploit DB
•added 2012/07/14 12:00 a.m.•76 views

Siemens Simatic S7-1200 - CPU START/STOP Module (Metasploit)

Exploit Title: Siemens Simatic S7 1200 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class Metasploit3 'Siemens Simatic S7-1200 CPU START/STOP Module', 'Description'...

5.3AI score
SaveExploits0
Exploit DB
Exploit DB
•added 2012/07/14 12:00 a.m.•136 views

Siemens Simatic S7-300 - PLC Remote Memory Viewer (Metasploit)

Exploit Title: Siemens Simatic S7 300 Remote Memory Viewer Backdoor Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class Metasploit3 'Siemens Simatic S7-300 PLC Remote Memory Viewer',...

5.3AI score
SaveExploits0
exploitpack
exploitpack
•added 2012/07/14 12:00 a.m.•54 views

Siemens Simatic S7-1200 - CPU STARTSTOP Module (Metasploit)

Siemens Simatic S7-1200 - CPU STARTSTOP Module Metasploit Exploit Title: Siemens Simatic S7 1200 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class Metasploit3...

7.4AI score
SaveExploits0
zdt
zdt
•added 2012/07/13 12:00 a.m.•48 views

Siemens Simatic S7-300 PLC Remote Memory Viewer

Exploit for hardware platform in category remote exploits Exploit Title: Siemens Simatic S7 300 Remote Memory Viewer Backdoor Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class...

7.1AI score
SaveExploits0
zdt
zdt
•added 2012/07/13 12:00 a.m.•58 views

Siemens Simatic S7-300/400 CPU START/STOP Module

Exploit for hardware platform in category remote exploits Exploit Title: Siemens Simatic S7 300/400 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-300 PLC CVE : None require 'msf/core' class Metasploit3...

7.1AI score
SaveExploits0
zdt
zdt
•added 2012/07/13 12:00 a.m.•68 views

Siemens Simatic S7-1200 CPU START/STOP Module

Exploit for hardware platform in category remote exploits Exploit Title: Siemens Simatic S7 1200 CPU command module Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class Metasploit3...

7.1AI score
SaveExploits0
ICS
ICS
•added 2012/07/01 6:00 a.m.•46 views

Optimalog Optima PLC Multiple Vulnerabilities

Overview Independent researcher Luigi Auriemma identified a NULL Pointer Dereference and an Infinite Loop and released proof-of-concept exploit code for Optimalog’s Optima PLC application without coordination with ICS-CERT, the vendor, or any other coordinating entity known to ICS-CERT. Optimalog...

7.8CVSS6.9AI score0.06722EPSS
SaveExploits1References10
Packet Storm
Packet Storm
•added 2012/06/29 12:00 a.m.•39 views

Access Bank Plc SQL Injection

1-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=0 0 1 1 /' \ /'\ /\ \ /'\ 0 0 /, \ /\/\ \ \ \ \ ,/\ /\ \ 1 1 //\ \ /' \ /\ //\ Exploit database separated by exploit 0 0 // type local, remote, DoS, etc. 1 1 1 0 x Official Website: http://www.1337day.com 0 1 x...

0.3AI score
SaveExploits0
zdt
zdt
•added 2012/05/10 12:00 a.m.•48 views

Access Bank PLC SQL injection Vulnerability

Exploit for php platform in category web applications Exploit Title: Access Bank PLC SQL injection Vulnerability Author: Mr.ExiT Home : Sh4ck.com ---------------------------------------------------------------------! Email : email protected Category: webapps Version: v1.0 Google dork: "powered by...

7.1AI score
SaveExploits0
ICS
ICS
•added 2012/05/03 6:00 a.m.•63 views

Siemens SIMATIC S7-400 PN CPU DoS

Overview Siemens has reported to ICS-CERT that denial-of-service DoS vulnerabilities exist in the SIMATIC S7-400 V6 and SIMATIC S7-400 V5 PN CPU products. Siemens has produced a firmware update that mitigates the vulnerability affecting the S7-400 V6. Siemens will not fix the vulnerability that...

7.8CVSS6.8AI score0.03464EPSS
SaveExploits0References10
ThreatPost
ThreatPost
•added 2012/04/05 5:30 p.m.•9 views

Project Basecamp Adds Stuxnet-type Attack Module to Metasploit

UPDATE: Project Basecamp, a volunteer effort to expose security holes in industrial control system software, unveiled new modules on Thursday to exploit holes in common programmable logic controllers PLCs. The new exploits, which are being submitted to the Metasploit open platform, include one th...

0.2AI score
SaveExploits0References7
Metasploit
Metasploit
•added 2012/04/05 12:00 a.m.•59 views

Schneider Modicon Remote START/STOP Command

The Schneider Modicon with Unity series of PLCs use Modbus function code 90 0x5a to perform administrative commands without authentication. This module allows a remote user to change the state of the PLC between STOP and RUN, allowing an attacker to end process control by the PLC. This module is...

5.5AI score
SaveExploits0
Metasploit
Metasploit
•added 2012/04/05 12:00 a.m.•57 views

Schneider Modicon Ladder Logic Upload/Download

The Schneider Modicon with Unity series of PLCs use Modbus function code 90 0x5a to send and receive ladder logic. The protocol is unauthenticated, and allows a rogue host to retrieve the existing logic and to upload new logic. Two modes are supported: "SEND" and "RECV," which behave as one might...

5.5AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:00 a.m.•11 views

Scada Modbus Write Request To PLC

There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...

6.9AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:00 a.m.•11 views

Scada Modbus Read Request To PLC

There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...

6.9AI score
SaveExploits0
ThreatPost
ThreatPost
•added 2012/02/14 7:49 p.m.•21 views

Bloody Valentine For Critical Infrastructure: EtherNet/IP Exploit Could Crash Devices

Security researchers made good on a promise to release new exploits for programmable logic controllers PLCs. The exploits include one targeting a flaw in the implementation of the EtherNet/IP Industrial Protocol used in many IP-enabled PLCs. The security hole, if left unaddressed, could enable a...

7.9AI score
SaveExploits0References7
ThreatPost
ThreatPost
•added 2012/02/10 2:58 p.m.•17 views

Cancun, Mexico

At Kaspersky Lab’s Security Analyst Summit last week, over 100 researchers and law enforcement officials converged in Cancun, Mexico over the course of five days to network and discuss a veritable cornucopia of security topics. Topics such as privacy, SCADA and PLC security, tracking cybercrimina...

0.4AI score
SaveExploits0References1
NVD
NVD
•added 2012/01/28 1:55 a.m.•19 views

CVE-2012-0929

Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the 1 FTP server or 2 HTTP server...

7.8CVSS7.6AI score0.04842EPSS
SaveExploits0References6
Rows per page
Query Builder