3068 matches found
Fatek Automation PLC WinProladder 3.11 Build 14701 - Stack Buffer Overflow (Metasploit)
require 'msf/core' class MetasploitModule 'Fatek Automation PLC WinProladder Stack-based Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in Fatek Automation PLC WinProladder v3.11 Build 14701. The vulnerability is triggered when a client connects to a...
ICSSPLOIT: A Industrial Control System Exploitation Framework
PenTestIT RSS Feed This framework is based on RouterSploit, which has already been covered on this blog. Infact, that's how I got to know about it - I was checking the source for updates and I found a reference for this Industrial Control System ICS exploitation framework - ICSSPLOIT. ICS securit...
Siemens SIMATIC S7 PLC Multiple Vulnerabilities (SSA-293562)
Siemens SIMATIC S7 devices are prone to multiple vulnerabilities. Copyright C 2017 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free...
CVE-2017-6017
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker...
CVE-2017-6017
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker...
Design/Logic Flaw
A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A...
CVE-2017-6030
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
Design/Logic Flaw
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker...
CVE-2017-7901
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series...
CVE-2017-7901
CVE-2017-7901 affects Rockwell Automation Allen-Bradley MicroLogix 1100 (1763-L16A.. series A/B, 16.00 and earlier) and MicroLogix 1400 (1766-L32A.. series A/B, 16.00 and earlier). Root cause: generation of insufficiently random TCP initial sequence numbers , enabling an attacker to predict numbe...
CVE-2017-6017
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker...
CVE-2017-6026
Affected products: Schneider Electric Modicon PLCs (M241 and M251) with firmware versions prior to 4.0.5.11. Root cause / vulnerability: Use of insufficiently random values in session numbers generated by the web application, leading to potential session compromise due to shared session identifie...
CVE-2017-7902
CVE-2017-7902 affects Rockwell Automation Allen‑Bradley MicroLogix 1100 (1763-L16Axx, 16.00 and earlier) and MicroLogix 1400 (1766-L32Axx, 16.00 and earlier). The issue is nonce reuse in encryption, enabling an attacker to capture and replay a valid request until the nonce changes, potentially co...
CVE-2017-6017
The CVE-2017-6017 issue affects Schneider Electric Modicon M340 PLCs (models BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, BMXP342030H). A remote attacker can send s...
Information Disclosure Vulnerability in Multiple Rockwell Automation Products
Rockwell Automation Allen-Bradley MicroLogix 1100 1763-L16AWA Series A and others are programmable logic controller PLC products from Rockwell Automation. An information disclosure vulnerability exists in multiple Rockwell Automation products. An attacker could exploit this vulnerability to recov...
Unspecified Vulnerability in Multiple Rockwell Automation Products (CNVD-2017-08711)
Rockwell Automation Allen-Bradley MicroLogix 1100 1763-L16AWA Series A and others are programmable logic controller PLC products from Rockwell Automation. A security vulnerability exists in several Rockwell Automation products. The vulnerability can be exploited by an attacker to repeatedly enter...
Schneider Electric SoMachine HVAC
CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Schneider Electric Equipment: SoMachine HVAC Vulnerabilities: Buffer Overflow, DLL Hijack AFFECTED PRODUCTS The following version of SoMachine HVAC, a PLC programming software, is affected: SoMachine HVAC Versions 2.1.0 and prior. IMPACT...
PT-2017-3703 · Schneider Electric · Modicon Premium +3
Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon BMXNOR0200 affected versions not specified Schneider Electric Modicon M340 affected versions not specified Schneider Electric Modicon Premium affected versions not specified Schneider Electric Modicon Quantum PLC...
Schneider Electric Modicon Modbus Protocol
CVSS v3 10.0 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: Modicon Modbus Protocol Vulnerabilities: Authentication Bypass by Capture-Replay, Violation of Secure Design Principles AFFECTED PRODUCTS The following versions of Modicon Modbus protoco...