Siemens SIMATIC S7 PLC Multiple Vulnerabilities (SSA-293562)
🗓️ 18 Aug 2017 00:00:00Reported by Copyright (C) 2017 Greenbone Networks GmbHType
openvas🔗 plugins.openvas.org👁 51 Views
10
| Source | Link |
|---|---|
| ics-cert | www.ics-cert.us-cert.gov/advisories/ICSA-17-129-02 |
| cert-portal | www.cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf |
# Copyright (C) 2017 Greenbone Networks GmbH
# Some text descriptions might be excerpted from (a) referenced
# source(s), and are Copyright (C) by the respective right holder(s).
#
# SPDX-License-Identifier: GPL-2.0-or-later
#
# This program is free software; you can redistribute it and/or
# modify it under the terms of the GNU General Public License
# as published by the Free Software Foundation; either version 2
# of the License, or (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program; if not, write to the Free Software
# Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA.
if (description)
{
script_oid("1.3.6.1.4.1.25623.1.0.140312");
script_version("2022-04-27T04:20:28+0000");
script_tag(name:"last_modification", value:"2022-04-27 04:20:28 +0000 (Wed, 27 Apr 2022)");
script_tag(name:"creation_date", value:"2017-08-18 11:51:47 +0700 (Fri, 18 Aug 2017)");
script_tag(name:"cvss_base", value:"6.1");
script_tag(name:"cvss_base_vector", value:"AV:A/AC:L/Au:N/C:N/I:N/A:C");
script_tag(name:"severity_vector", value:"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_tag(name:"severity_origin", value:"NVD");
script_tag(name:"severity_date", value:"2021-03-15 18:15:00 +0000 (Mon, 15 Mar 2021)");
script_cve_id("CVE-2017-2680", "CVE-2017-2681");
script_tag(name:"qod_type", value:"remote_banner");
script_tag(name:"solution_type", value:"VendorFix");
script_name("Siemens SIMATIC S7 PLC Multiple Vulnerabilities (SSA-293562)");
script_category(ACT_GATHER_INFO);
script_copyright("Copyright (C) 2017 Greenbone Networks GmbH");
script_family("General");
script_dependencies("gb_siemens_simatic_s7_consolidation.nasl");
script_mandatory_keys("siemens/simatic_s7/detected", "siemens/simatic_s7/version");
script_tag(name:"summary", value:"Siemens SIMATIC S7 devices are prone to multiple
vulnerabilities.");
script_tag(name:"vuldetect", value:"Checks if a vulnerable version is present on the target host.");
script_tag(name:"insight", value:"The following flaws exist:
- CVE-2017-2680: Specially crafted PROFINET DCP broadcast packets could cause a denial-of-service
condition of affected products on a local Ethernet segment (Layer 2). Human interaction is
required to recover the systems. PROFIBUS interfaces are not affected.
- CVE-2017-2681: Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2)
to an affected product could cause a denial-of-service condition in that product. Human
interaction is required to recover the system. PROFIBUS interfaces are not affected.");
script_tag(name:"impact", value:"A remote attacker may cause a DoS condition.");
script_tag(name:"solution", value:"Siemens provides updated firmware versions. Please see the
references for more information.");
script_xref(name:"URL", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf");
script_xref(name:"URL", value:"https://ics-cert.us-cert.gov/advisories/ICSA-17-129-02");
exit(0);
}
include("host_details.inc");
include("version_func.inc");
model = get_kb_item("siemens/simatic_s7/model");
if (model !~ "^(12|15|3|4)[0-9]{2}")
exit(0);
moduleType = get_kb_item("siemens/simatic_s7/modtype");
if (!fw = get_kb_item("siemens/simatic_s7/version"))
exit(0);
if (model =~ "^3") {
if ((moduleType =~ "^CPU 314C" || model =~ "^314C") && version_is_less(version: fw, test_version: "3.3.14")) {
report = report_fixed_ver(installed_version: fw, fixed_version: "3.3.14");
security_message(port: 0, data: report);
exit(0);
}
if ((moduleType =~ "^CPU 3(15|17|19)" || model =~ "^3(15|17|19)") &&
version_is_less(version: fw, test_version: "3.2.14")) {
report = report_fixed_ver(installed_version: fw, fixed_version: "3.2.14");
security_message(port: 0, data: report);
exit(0);
}
}
if (model =~ "^4") {
if (moduleType =~ "^CPU 41(2|4|6|7)" && version_is_less(version: fw, test_version: "6.0.1")) {
report = report_fixed_ver(installed_version: fw, fixed_version: "6.0.1");
security_message(port: 0, data: report);
exit(0);
}
if (moduleType =~ "^CPU 410" && version_is_less(version: fw, test_version: "8.2.0")) {
report = report_fixed_ver(installed_version: fw, fixed_version: "8.2.0");
security_message(port: 0, data: report);
exit(0);
}
}
if ((model == "1200" || moduleType =~ "^CPU.1200") && version_is_less(version: fw, test_version: "4.2")) {
report = report_fixed_ver(installed_version: fw, fixed_version: "4.2");
security_message(port: 0, data: report);
exit(0);
}
if ((model == "1500" || moduleType =~ "^CPU.1500") && version_is_less(version: fw, test_version: "2.1.0")) {
report = report_fixed_ver(installed_version: fw, fixed_version: "2.1.0");
security_message(port: 0, data: report);
exit(0);
}
exit(99);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
27 Apr 2022 00:00Current
6.7Medium risk
Vulners AI Score6.7
CVSS 26.1
CVSS 3.16.5
CVSS 47.1
EPSS0.01149
SSVC