Lucene search
+L

1316 matches found

Prion
Prion
added 2012/02/21 1:31 p.m.15 views

Buffer overflow

Buffer overflow in the Advantech ADAM OLE for Process Control OPC Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors...

10CVSS8.6AI score0.03925EPSS
SaveExploits0References1Affected Software3
CVE
CVE
added 2012/02/21 11:0 a.m.66 views

CVE-2011-1914

CVE-2011-1914 describes a buffer overflow in the Advantech ADAM OPC Server ActiveX control used by multiple ADAM OPC Server products. The vulnerability affects ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010, enabling remote code e...

10CVSS8.3AI score0.03925EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2012/02/21 11:0 a.m.26 views

CVE-2011-1914

Buffer overflow in the Advantech ADAM OLE for Process Control OPC Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors...

8AI score0.03925EPSS
SaveExploits0References1
ICS
ICS
added 2012/02/11 7:0 a.m.28 views

Progea Movicon Memory Corruption Vulnerability

Overview Security researcher Dillon Beresford of IXIAhttp://www.ixiacom.com/, website last accessed May 10, 2012. has identified a memory corruption vulnerability in the Progea Movicon application. This vulnerability can be exploited by a remote attacker; however, no public exploits are currently...

7.8CVSS7.2AI score0.02848EPSS
SaveExploits0References10
OpenVAS
OpenVAS
added 2012/01/20 12:0 a.m.22 views

Cogent OPC DataHub and Cascade DataHub XSS and CRLF Vulnerabilities

This host is installed with OPC DataHub or Cascade DataHub and is prone to cross site scripting and CRLF vulnerabilities. OpenVAS Vulnerability Test $Id: gbcogentcascadenopcdatahubmultvuln.nasl 6022 2017-04-25 12:51:04Z teissa $ Cogent OPC DataHub and Cascade DataHub XSS and CRLF Vulnerabilities...

5.8CVSS0.5AI score0.01512EPSS
SaveExploits0References4
OpenVAS
OpenVAS
added 2012/01/20 12:0 a.m.33 views

Cogent OPC DataHub and Cascade DataHub < 7.2 XSS and CRLF Vulnerabilities

OPC DataHub or Cascade DataHub is prone to multiple cross-site scripting XSS and CRLF vulnerabilities. SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier:...

5.8CVSS6AI score0.01512EPSS
SaveExploits0References5
Cvelist
Cvelist
added 2012/01/13 2:0 a.m.26 views

CVE-2012-0309

Cross-site scripting XSS vulnerability in Cogent DataHub 7.1.2 and earlier, Cascade DataHub 6.4.20 and earlier, and OPC DataHub 6.4.20 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...

5.6AI score0.01341EPSS
SaveExploits0References8
NVD
NVD
added 2011/11/04 9:55 p.m.20 views

CVE-2011-3330

Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and...

7.2CVSS7.7AI score0.01302EPSS
SaveExploits0References6
Prion
Prion
added 2011/11/04 9:55 p.m.15 views

Buffer overflow

Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and...

7.2CVSS8.4AI score0.01302EPSS
SaveExploits0References6Affected Software6
CVE
CVE
added 2011/11/04 9:0 p.m.73 views

CVE-2011-3330

Buffer overflow in the UnitelWay Windows Device Driver used by Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier allows local users to execute arbi...

7.2CVSS8AI score0.01302EPSS
SaveExploits0References6Affected Software6
Cvelist
Cvelist
added 2011/11/04 9:0 p.m.26 views

CVE-2011-3330

Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and...

7.7AI score0.01302EPSS
SaveExploits0References6
Packet Storm
Packet Storm
added 2011/10/11 12:0 a.m.26 views

OPC Systems.NET 4.00.0048 Denial Of Service

Luigi Auriemma Application: OPC Systems.NET http://www.opcsystems.com/opcsystemsnet.htm Versions: = 4.00.0048 Platforms: Windows Bug: Denial of Service Exploitation: remote Date: 10 Oct 2011 Author: Luigi Auriemma e-mail: [email protected] web: aluigi.org 1 Introduction 2 Bug 3 The Code 4 Fix...

7.4AI score
SaveExploits0
exploitpack
exploitpack
added 2011/10/10 12:0 a.m.20 views

OPC Systems.NET 4.00.0048 - Denial of Service

OPC Systems.NET 4.00.0048 - Denial of Service Luigi Auriemma Application: OPC Systems.NET http://www.opcsystems.com/opcsystemsnet.htm Versions: = 4.00.0048 Platforms: Windows Bug: Denial of Service Exploitation: remote Date: 10 Oct 2011 Author: Luigi Auriemma e-mail: [email protected] web:...

7.3AI score
SaveExploits0
Exploit DB
Exploit DB
added 2011/10/10 12:0 a.m.25 views

OPC Systems.NET 4.00.0048 - Denial of Service

Luigi Auriemma Application: OPC Systems.NET http://www.opcsystems.com/opcsystemsnet.htm Versions: = 4.00.0048 Platforms: Windows Bug: Denial of Service Exploitation: remote Date: 10 Oct 2011 Author: Luigi Auriemma e-mail: [email protected] web: aluigi.org 1 Introduction 2 Bug 3 The Code 4 Fix...

5CVSS5.2AI score0.03159EPSS
SaveExploits1
Metasploit
Metasploit
added 2011/08/11 8:41 a.m.29 views

TeeChart Professional ActiveX Control Trusted Integer Dereference

This module exploits an integer overflow in TeeChart Pro ActiveX control. When sending an overly large/negative integer value to the AddSeries property of TeeChart2010.ocx, the code will perform an arithmetic operation that wraps the value and is later directly trusted and called upon. This modul...

7.5AI score
SaveExploits0
Exploit DB
Exploit DB
added 2011/08/11 12:0 a.m.41 views

TeeChart Professional ActiveX Control 2010.0.0.3 - Trusted Integer Dereference (Metasploit)

$Id: teechartpro.rb 13522 2011-08-11 11:17:30Z swtornio $ This file is part of the Metasploit Framework and may be subject to redistribution and commercial restrictions. Please see the Metasploit Framework web site for more information on licensing and terms of use. http://metasploit.com/framewor...

5.3AI score
SaveExploits0
ICS
ICS
added 2011/07/09 6:0 a.m.25 views

Unitronics UNIOPC Server Input Handling Vulnerability

Overview Independent security researchers Billy Rios and Terry McCorkle have identified a vulnerability in Unitronics’ UniOPC Server product. --------- Begin Update A Part 1 of 3 -------- This vulnerability is a result of improper handling of input by a third-party component, https50.ocx, which i...

6.8CVSS8.1AI score0.01677EPSS
SaveExploits0References10
ICS
ICS
added 2011/07/09 6:0 a.m.45 views

Advantech OPC Server Buffer Overflow

Overview ICS-CERT originally released Advisory ICSA-11-279-01P on the US-CERT secure Portal on October 06, 2011. This web page release was delayed to allow users time to download and install the update. Security research and service institute Information and Communication Security Technology Cent...

10CVSS8.7AI score0.03925EPSS
SaveExploits0References10
zdt
zdt
added 2011/05/03 12:0 a.m.29 views

ICONICS WebHMI ActiveX Stack Overflow

Exploit for windows platform in category remote exploits , , . .' '. ', . , '. , ., , / / / \ \ ==/ /\ \ / / \ / \ / / | \ \ Y Y \ / /| / \ /||| / / /.-. / /:wq x.0 '=.|w|.=' ='"=. presents.. ICONICS WebHMI ActiveX Stack Overflow Vendor Link: http://www.iconics.com/ PDF:...

7.1AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2011/04/27 12:0 a.m.9 views

Automated Solutions Modbus/TCP OPC Server Detection

Binary data scadaappautomatedasmbtcpopcdetect.nbin...

7.3AI score
SaveExploits0References1
Rows per page
Query Builder